Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 April 2020Resolved
Manned OCS facilities shall be provided w/at least 2 primary means of escape. Means of escape on fwd column found damaged. ABS condition of class in place. 33CFR 143.101. 705 a, c
Action required: 705 - Other - as specified
Due 17 June 2020
Resolved 17 June 2020
Resolution: Ensured converted to condition of class to be cleared by ABS. Check next COI
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 17 April 2020Resolved
The emergency equipment provided shall be maintained in good condition at all times. Monthly OEM releasing gear maintenance for LB 1&2 were not being conducted. Quarterly lubrication of cables for LB 1&2 were not being conducted. Evaluate PQS, make changes and lubricate appropriate equipment as necessary. 33CFR 146.15(a). 50 c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2020
Resolved 17 June 2020
Resolution: Received clearance documentation from OIM.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 April 2020Resolved
The emergency equipment provided shall be maintained in good condition at all times. FP #1 failed to start as designed on loss of FM pressure. 33CFR 146.15. 50 c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2020
Resolved 17 June 2020
Resolution: Received clearance documentation from OIM.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 28 May 2019Resolved
The operator os a vessel with a capacity of 250 or more barrels of oil....shall provide transfer procedures that meet the requirements of this part. No fuel trasnfer procedures could be provided at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 28 June 2019
Resolution: OIM [name withheld] provided documentation for clearance.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 May 2019Resolved
Manned OCS facilities shall be provided with at least 2 primary means of escape. Means of escape and personnel landing on forward column found damaged.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 July 2019
Resolved 9 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 May 2019Resolved
Each cable splice must be made in accordance with section 25.11 of IEEE 45-2002 and ABS rules. Several non-compliant splices were identified inside battery enclosures. Conduct full audit of enclosures and properly repair.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 28 June 2019
Resolution: OIM [name withheld] provided documentation for clearance.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 May 2019Resolved
Each space protected by a CO2 system must have the following means for closing the openings to the space...doors, shutters or dampers. Glass in AUX Gen enclosure found broken at time of the inspection. Doors and openings for E-Gen enclosure found damaged so as to question the integrity of the space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 9 March 2021
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 May 2019Resolved
Machinery driving...fuel oil unit and service pumps must be fitted with remote controls...so that fans or pumps may be stopped in case of fire in the compartment. Emergency fuel shutoff remote pull found inoperable and unable to shut down engine.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 28 June 2019
Resolution: OIM [name withheld] provided documentation for clearance.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 May 2019Resolved
This section applies to vents for all independent, fixed, non-pressure tanks or containers or for spaces in which liquids such as fuel, ships stores, cargo or ballast are carried. Wastage on diesel fuel vents, ballast vents, flame screens and closures on several installations was identified. COnduct full audit of tank vent installations and make proper repairs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 28 June 2019
Resolution: OIM [name withheld] provided documentation for clearance.
Construction/Loadline › Structures › Door
Issued 17 March 2016Resolved
Each combination galley/messroom must be an A class bulkhead and A class deck. door to messroom was missing a latch.
Condition: Improper/Lack of Maintenance
Due 21 March 2016
Resolved 17 March 2016
Resolution: Replaced.