ODYSSEA COURAGE

ODYSSEA COURAGE is a 1999 industrial vessel. The Coast Guard has recorded 56 inspections since 1999, most recently in June 2026, along with 84 deficiencies and 5 casualty investigations between 2009 and 2018.

Records from 1999 to 2026. Most recent: inspection, 25 June 2026.

Built
1999
Last inspected
25 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9213040 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDF7773
489245
Flag
UNITED STATES
366677000
Maury page id
psix-489245

Inspections, by type

…with no type recorded9
Years with a record 24 calendar years (1999–2026)
The 56 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)214.4 ft × 48.0 ft × 16.0 ft
Registered tonnagegross 1,342 / net 402
ITC dimensions (L × B × D)214.4 ft × 48.0 ft × 16.0 ft
ITC tonnagegross 1,342 / net 402
BuilderEASTERN SHIPBUILDING INC · PANAMA CITY, FL, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 31 March 2026 · expires 30 April 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1342 - Convention (Subpart B), Gross Ton
402 - Convention (Subpart B), Net Ton
1868 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF7773MMSI 366677000 · active · compulsorily equipped · granted 17 March 2021, expires 28 April 2031
WCZ2334MMSI 369533000 · cancelled · compulsorily equipped · granted 3 March 2009, cancelled 1 April 2011
WCY9909MMSI 338444000 · cancelled · compulsorily equipped · granted 12 April 1999, cancelled 9 April 2003
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 13

Inspection history · 56

25 June 2026 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8392924
9 July 2025 ACP Periodic Oversight · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8168788
14 August 2024 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7981033
12 June 2024 Administrative Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7933343
11 October 2023 Deficiency Check · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7806221
22 June 2023 Administrative Inspection · MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7719461
3 February 2023 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7631771
28 March 2022 MARPOL Annex IV Survey · Drydock Exam · COI Inspection · MTSA/ISPS Verification · Cargo Tank Internal · MARPOL Annex VI Survey · Internal Structural Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7419755
8 July 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7249089
30 April 2020 Periodic Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6946045
23 July 2019 Administrative Inspection · MARPOL Annex VI Survey · MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6759268
21 May 2019 Administrative Inspection · Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6689745
16 April 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6392223
13 April 2018 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6390902
28 March 2018 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6380817
25 March 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6381488
14 September 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6266411
13 April 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6123580
12 April 2017 Administrative Inspection · COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6122267
3 April 2017 Internal Structural Exam · Cargo Tank Internal · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6113847
24 January 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6075863
11 April 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5852003
9 October 2015 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5739809
28 August 2015 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5228637
2 May 2012 Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4300237
1 December 2009 Type not recorded
No type recorded · Commandant (CG-INV) · Activity 4043320
6 July 2009 Annual Inspection · Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Activities Europe · Activity 3533204
6 March 2009 Type not recorded
No type recorded · Activities Europe · Activity 3428535
5 March 2009 Damage Survey
Physical examination · Activities Europe · Activity 3428086
21 February 2009 Type not recorded
No type recorded · Activities Europe · Activity 3426723
21 February 2009 Type not recorded
No type recorded · Activities Europe · Activity 3428532
6 January 2009 Type not recorded
No type recorded · Activities Europe · Activity 3417140
17 July 2008 Periodic Inspection
Physical examination · Activities Europe · Activity 3277388
16 July 2007 Annual Inspection
Physical examination · Activities Europe · Activity 2955163
20 August 2006 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Activities Europe · Activity 2709083
1 May 2006 Deficiency Check · MARPOL Annex I Examination · COI Inspection
Physical examination · Activities Europe · Activity 2607138
16 February 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2586284
22 March 2005 MARPOL Annex I Examination · MTSA/ISPS Verification · Ballast Water Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2317016
21 March 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2315427
23 July 2004 Internal Structural Exam · Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2130776
7 June 2004 MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2066560
25 August 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1950105
24 July 2003 Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1855757
5 September 2002 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1671373
14 August 2002 Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1661532
20 August 2001 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1462253
12 July 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 52107
15 May 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439204
16 February 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1058663
19 October 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 823296
19 October 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1054975
20 June 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1050660
12 June 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427847
21 December 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 824714
29 June 1999 Initial Construction-Excluding Oversight
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1056505
29 June 1999 Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1405008

Deficiency record · 84

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 June 2026 Resolved
Each davit, winch and fall must be thoroughly inspected at least once a year. Annual servicing not completed. Last service for rescue boat davit was on 04/03/2025. 46 CFR 131.575(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2026
Resolution: Received service report from authorized servicing dealer (added to documents).
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 June 2024 Resolved
The internal structural members of an OSV must be examined at the same intervals required for drydocking by paragraph (a) of this section. Worklist Item's as follows. 1. Main engine room: Emergency escape STBD Side bondo on ladder rung. 2. Main engine room: Emergency escape STBD side door gasket. 3. #4 Port Ballast: Sounding tube wasted. 4. Main Deck: 02 deck P/S doors unable to open. 5. Hull: P/S prop nuts need replacement. 6. Main deck: Standpipes need to be replaced. 7. #3: Striker plate needs to be replaced.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 16 July 2024
Resolution: Worklist item's completed
05 - Radio Communications › N/A - No Subsystem › Operation of GMDSS equipment
Issued 22 June 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2023
Resolved 27 August 2023
Resolution: Vessel Rep provided receipt and FCC tech report stating installiation and testing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2020 Resolved
Lifebuoys fitted with self-igniting lights must be approved under 161.010. Multiple lifebuoy lights' batteries found to be expired. 46 CFR 133.70 (a)(4)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2020
Resolved 1 May 2020
Resolution: Installed new batteries.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 30 April 2020 Resolved
Nonmetallic flexible hose must be in accordance with SAE J1942. Found 2 unapproved flexible hoses serving the fuel supply and return line to the emergency generator. 46 CFR 56.60-25(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2020
Resolved 20 May 2020
Resolution: Received pictures of approved supply and return hoses.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 April 2020 Resolved
Vessels > 1,000 GTs but < 1500 GTs must be equipped with 2 independently driven fire pumps. The vessels main fire pump did not operate properly. 46 CFR 95.10-5(a)
Action required: 10 - Deficiency Rectified
Due 30 April 2020
Resolved 30 April 2020
Resolution: Fixed on spot.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 30 April 2020 Resolved
In spaces where the general emergency alarm signal cannot be heard over the background noise, there must be a red flashing light or rotting beacon in addition to the emergency alarm signal. Beacon in rudder room discovered to be out and not working. 46 CFR 113.25-10(a)
Action required: 10 - Deficiency Rectified
Due 30 April 2020
Resolved 30 April 2020
Resolution: Fixed on spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 July 2019 Resolved
Locks for CO2 system lockout valves were missing. The Master must ensure all lockout valves are installed and locked in the open position unless maintenance is being performed on the system.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2019
Resolved 26 July 2019
Resolution: Cleared
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 23 July 2019 Resolved
Ground detection in E-Gen space inoperable. There must be operating ground detection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2019
Resolved 26 July 2019
Resolution: Cleared
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 July 2019 Resolved
Fire alarm panel on bridge contains a fault. Panel must be tested and function IAW manufacturer's instructions.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2019
Resolved 26 July 2019
Resolution: Cleared
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 23 July 2019 Resolved
Each survival craft must be stripped clean, and repaired as needed. Ensure rescue boat is repaired and ready for operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2019
Resolved 26 July 2019
Resolution: Cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 July 2019 Resolved
Expansion joints must be examined externally at every inspection for physical damage. Nonmetallic expansion joint installed on bow thruster prime mover has a cut and is damaged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 26 July 2019
Resolution: Cleared
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 23 July 2019 Resolved
E-gen space door is missing gaskets and securing bolt was rusted shut. Where natural ventilation is provided for spaces protected by CO2, provisions shall be made for easily and effectively closing off ventilation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2019
Resolved 26 July 2019
Resolution: Cleared
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 23 July 2019 Resolved
Life raft installations must be made such that there is 100% capacity for total number of persons on board with the ability to lose the largest survival craft on one side. Transferable life raft to fulfill the requirement must be provided with side to side transfer capability.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2019
Resolved 26 July 2019
Resolution: Cleared
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 July 2019 Resolved
Watertight escape hatch between mess deck and 01 deck had improper gasketing, and multiple watertight doors between engine room and bow thruster room required adjustments. IAW 46 CFR 131.520, all watertight openings and exposed hatches shall be made watertight by proper use of gasketing and fittings.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2019
Resolved 26 July 2019
Resolution: Cleared
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 23 July 2019 Resolved
The spotlight for the rescue boat was not operable. The spotlight should be constructed and marked IAW ASTM F1014 and one spare set of batteries must be provided.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2019
Resolved 26 July 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 July 2019 Resolved
Entrance to fixed CO2 fire extinguishing storage room did not have any signs warning of hazards in space. Space must be marked IAW 46 CFR 97.37-11.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 26 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 July 2019 Resolved
Two (02) self-activating smoke signals attached to bridge buoys on board were not marked with a expiration date from manufacturer. IAW 46 CFR 160.057-5(b)(1), the smoke signals shall be marked with the service life expiration date, month and year, by the manufacturer. Owner shall provide proof of manufacturer's expiration date for smoke floats.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2019
Resolved 26 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 July 2019 Resolved
Installation of fireproof/watertight penetration was incorrect on starboard side bridge in cabinet containing fire-men's outfit. Installation of penetration must be made IAW manufacturer's instruction to ensure watertight integrity and fire safety of vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 26 July 2019
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 11 April 2016 Resolved
vessel has sufficent lifesaving onboard, however the side to side transferable life raft needs to be lifted too far per the one foot height requirement to be launched. required vsl rep to provide a repair proposal to fix the issue to the attending inspector prior to completion of the next drydock.
Action required: 705 - Other - as specified
Resolved 23 July 2019
Resolution: Configuration was altered to prevent the need to lift the life raft.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 2 May 2012 Resolved
VESSEL HAS A NON TANK VESSEL RESPONSE PLAN BUT IS NOT AUTHORIZED FOR SECTOR SAN JUAN ZONE.
Due 2 May 2012
Resolved 3 July 2013
Resolution: Vessel has a non tank vessel response plan with an authorized san jaun cotp zone.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 12 August 2009 Resolved
The following Class certificates are expired: Class, Loadline, Safety Construction and Safety Radio.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2009
Engineering › Generator (propulsion/auxiliary-electric) › Generator Voltage Regulator Circuitry
Issued 12 August 2009 Resolved
Prove proper operation of Port SSDG, to include testing of all alarms and shutdowns
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 12 August 2009 Resolved
Conduct testing of the CO2 fixed firefighting system in the presences of the USCG
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2009
Communications › Long Range Identification and Tracking (LRIT) › Software Package Update
Issued 12 August 2009 Resolved
Prove proper operation of the LRIT installation (Conformity Report). SOLAS Safety Equipment cannot be endorsed until proven.
Due 12 September 2009
Resolved 12 August 2009
Construction/Loadline › Structures › Door
Issued 12 August 2009 Resolved
Replace gasket on stbd. Engine room escape hatch cover.
Due 12 September 2009
Resolved 12 August 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 12 August 2009 Resolved
Repair port and starboard MDE & SSDG exhaust lagging insulation.
Due 12 October 2009
Resolved 9 October 2009
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 July 2009 Resolved
Replace damaged IMO life saving signage throughout vessel as necessary
Due 12 September 2009
Resolved 12 August 2009
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 6 July 2009 Resolved
Obtain documentation and mark Port side liferaft hydrostatic release units.
Due 12 September 2009
Resolved 12 August 2009
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 July 2009 Resolved
Remove all debris from bilge and pump the same proving oil record book entries.
Due 12 September 2009
Resolved 12 August 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 6 July 2009 Resolved
Prove wiring compliance with IEEE and ABS rules (plastic vs. metal banding). (60 days to complete)
Action required: 705 - Other - as specified
Due 12 November 2009
Resolved 1 October 2009
Electrical › Electric Generation Source (service) › Panelboard
Issued 6 July 2009 Resolved
Repair port and starboard shaft tachometers.
Due 12 September 2009
Resolved 12 August 2009
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 6 July 2009 Resolved
Replace matting at Main Switchboard.
Due 12 September 2009
Resolved 12 August 2009
Electrical › Lighting (service) › Conductor
Issued 6 July 2009 Resolved
Remove bailing wire from stbd aft steering lighting and attach properly.
Due 12 September 2009
Resolved 12 August 2009
Electrical › Lighting (service) › Conductor
Issued 6 July 2009 Resolved
Remove bailing wire from inboard compressor pressure switch .
Due 12 September 2009
Resolved 12 August 2009
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 6 July 2009 Resolved
Replace shroud on inboard air compressor.
Due 12 September 2009
Resolved 12 August 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 6 July 2009 Resolved
Ensure all engine room lights wires are properly in packing glands.
Action required: 705 - Other - as specified
Due 12 October 2009
Resolved 9 October 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 6 July 2009 Resolved
Hard wire light in the thruster room.
Due 12 September 2009
Resolved 12 August 2009
Electrical › Electrical Distribution System (service) › Cable
Issued 6 July 2009 Resolved
Remove portable cable from the potable water pump and repair/replace with marine grade wiring.
Action required: 705 - Other - as specified
Due 12 September 2009
Resolved 26 August 2009
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 6 July 2009 Resolved
Prove local alarm bell/light on stbd MDE.
Due 12 September 2009
Resolved 1 October 2009
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 6 July 2009 Resolved
Update circuit directories to reflect ampacity of breakers and appropriate circuit assignment.
Due 12 October 2009
Resolved 9 October 2009
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 6 July 2009 Resolved
Prove emergency fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2009
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 July 2009 Resolved
Prove proper operation of OWS.
Due 12 September 2009
Resolved 12 August 2009
Lifesaving › Rescue Boat Equipment › First Aid Kit
Issued 6 July 2009 Resolved
Provide approved equipment for rescue boat i.a.w. 46CFR 199.175.
Due 12 September 2009
Resolved 9 October 2009
Lifesaving › Rescue Boat › Markings
Issued 6 July 2009 Resolved
Properly mark rescue boat i.a.w. 46CFR 199.176. (vessel name on both sides and number of persons allowed)
Due 12 September 2009
Resolved 12 August 2009
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 6 July 2009 Resolved
Properly conduct operational readiness, maintenance and inspection of lifesaving equipment i.a.w. 46CFR 199.190 to include the use of proper checklists, weekly, monthly and annual inspections and tests as required. Properly maintain all lifesaving maintenance records as required. Clearded via email. Verify at next visit. Item cleared via email, verify at next attendance.
Due 1 August 2010
Resolved 15 July 2010
Resolution: vessel''s SMS was followed & tracking lifesaving inspection and equipment i.a.w. 46CFR199.190.
Lifesaving › Rescue Boat Equipment › Searchlight
Issued 6 July 2009 Resolved
Properly secure rescue boat equipment i.a.w. 46CFR 199.175
Due 12 September 2009
Resolved 12 August 2009
Documentation › Logs/Records › Logbook (official)
Issued 6 July 2009 Resolved
Use authorized official log book on bridge and submit to USCG for review as required. Clearded via email. Verify at next visit
Action required: 705 - Other - as specified
Due 1 August 2010
Resolved 15 July 2010
Resolution: Official log book in use as required.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 6 July 2009 Resolved
Provide documentation that the rescue boat hook release is USCG approved or replace it. If replaced, conduct proper load test.
Action required: 705 - Other - as specified
Due 12 October 2009
Resolved 9 October 2009
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 6 July 2009 Resolved
Prove proper operation of davit winch brake system.
Due 12 September 2009
Resolved 1 October 2009
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 6 July 2009 Resolved
Remove old OWS system (bilge boy). Old unit is OOC and not in use.
Action required: 705 - Other - as specified
Due 12 November 2009
Resolved 1 October 2009
Construction/Loadline › Hull › Hull Plating
Issued 5 March 2009 Resolved
Complete permanent repairs to the satisfaction of the attending USCG inspector to the crack located in #3 STBD Fuel Tank. Prior to the permanent repair soundings must be completed and recorded in the official log every 12 hours. If there is any change in the condition of the tank or the temporary repair this office must be notified as soon as possible.
Due 30 June 2009
Resolved 12 August 2009
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 July 2008 Resolved
Provide written documentation regarding the replacement of the OWS. Including timeline of installation. Remove all installed fixed piping / portable bilge pumps running from the port & stbd EMD’s to the fire main overboard discharge. Remove the quick connect coupling from the top of the oil content meter. Retain all oily waste onboard in authorized waste tanks until the new installation is approve
Action required: 705 - Other - as specified
Due 31 December 2008
Resolved 1 November 2008
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 17 July 2008 Resolved
Replace the stbd SART battery. Rcvd email from captain stating that the item has been corrected, verify at next CG visit.
Due 1 August 2009
Resolved 12 August 2009
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 17 July 2008 Resolved
Provide approved fire extinguisher for the FRC. Rcvd email from captain stating that the item has been corrected, verify at next CG visit.
Due 1 August 2009
Resolved 26 August 2009
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 17 July 2008 Resolved
Properly secure the welding machine power cable connection in the engine room. Rcvd email from captain stating that the item has been corrected, verify at next CG visit.
Due 1 August 2009
Resolved 12 August 2009
Lifesaving › Launching Appliances › Davit
Issued 17 July 2008 Resolved
Conduct proper annual servicing of the FRC launching appliance and release gear by an approved manufacturer or representative. Rcvd email from Captain stating that item has been cleared, to be verfied at the next CG attendance.
Due 1 August 2009
Resolved 12 August 2009
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 17 July 2008 Resolved
Properly secure / remove the unknown hose port side engine room in overhead. Rcvd email from captain stating that the item has been corrected, verify at next CG visit.
Due 1 August 2009
Resolved 12 August 2009
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 17 July 2008 Resolved
Provide written documentation on the estimated delivery / installation of the new rescue boat & engine room supply blower. Rcvd email from Captain that item was cleared, to be verified at next CG attendance.
Due 1 August 2009
Resolved 12 August 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 17 July 2008 Resolved
Provide documentation that the nitrogen CO2 local release bottles for the engine room are satisfactory.
Due 10 September 2008
Resolved 19 September 2008
Lifesaving › Lifebuoys › Stowage
Issued 17 July 2007 Resolved
Repair / replace lifering bracket on the STBD side main deck. Item reported cleared via E-mail dated 23 July 07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2008
Resolved 17 July 2008
Fire Fighting › Fire Hydrants › Condition
Issued 16 July 2007 Resolved
Repair valve handles on mud tanks and fire stations on the main deck. Item reported cleared via E-mail dated 23 July 07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2009
Resolved 12 August 2009
Construction/Loadline › Structures › Door
Issued 16 July 2007 Resolved
Provide and properly install gaskets in water tight doors. Item reported cleared via E-mail dated 23 July 07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2008
Resolved 17 July 2008
Fire Fighting › Fire Pumps › Gland Sealing
Issued 16 July 2007 Resolved
Replace mechanical seal on the fire pump. Item reported cleared via E-mail dated 20 September 07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 1 August 2008
Resolved 17 July 2008
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 16 July 2007 Resolved
Provide SOPEP approval letter for 2004-2009. Item reported cleared via E-mail dated 23 July 07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 1 August 2008
Resolved 17 July 2008
Navigation › Piloting/Steering › Compass Deviation Table
Issued 1 May 2006 Resolved
Calibrate magnetic compass and provide new deviation card. Item cleared via e-mail dated June 6, 2006. Compliance date extended to 8/1/2007 (90 days after the anniversary date) pending on-scene verification by next attending [name withheld] #2607138 for details.
Action required: 705 - Other - as specified
Due 1 August 2007
Resolved 20 August 2006
Resolution: Sighted new deviation.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 1 May 2006 Resolved
Clean the entire length of the dryer and galley vents. Item cleared via e-mail dated May 9, 2006. Compliance date extended to 8/1/2007 (90 days after the anniversary date) pending on-scene verification by next attending [name withheld] #2607138 for details.
Action required: 705 - Other - as specified
Due 1 August 2007
Resolved 20 August 2006
Resolution: Cleared
Communications › Radio Communications › Satellite Communications Capability
Issued 1 May 2006 Resolved
Demonstrate proper operation of the Inmarsat-C system. Item cleared via e-mail dated May 9, 2006. Compliance date extended to 8/1/2007 (90 days after the anniversary date) pending on-scene verification by next attending [name withheld] #2607138 for details..
Action required: 705 - Other - as specified
Due 1 August 2007
Resolved 20 August 2006
Resolution: Vessel had undergone a Radio survey with no def. Captain operated it, Sat.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 1 May 2006 Resolved
Demonstrate the proper operation of the rudder angle indicators in the wheelhouse and rudder room. Item cleared via e-mail dated June 6, 2006. Compliance date extended to 8/1/2007 (90 days after the anniversary date) pending on-scene verification by next attending [name withheld] #2607138 for details.
Action required: 705 - Other - as specified
Due 1 August 2007
Resolved 20 August 2006
Resolution: Tested, sat.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 1 May 2006 Resolved
Place valid and original Cargo Ship Safety Radio Certificate aboard the vessel. Item cleared via e-mail dated June 6, 2006. Compliance date extended to 8/1/2007 (90 days after the anniversary date) pending on-scene verification by next attending [name withheld] #2607138 for details..
Action required: 705 - Other - as specified
Due 1 August 2007
Resolved 20 August 2006
Resolution: ABs issued new Cert after Radio survey completed.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 1 May 2006 Resolved
Paint amidships load line and plimsol mark a contrasting color to the hull. Item cleared via e-mail dated May 9, 2006. Compliance date extended to 8/1/2007 (90 days after the anniversary date) pending on-scene verification by next attending [name withheld] #2607138 for details.
Action required: 705 - Other - as specified
Due 1 August 2007
Resolved 20 August 2006
Resolution: Done.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 1 May 2006 Resolved
Demonstrate proper operation of the oily water separator, content meter and alarms. Item cleared via e-mail dated May 9, 2006. Compliance date extended to 8/1/2007 (90 days after the anniversary date) pending on-scene verification by next attending [name withheld] #2607138 for details.
Action required: 705 - Other - as specified
Due 1 August 2007
Resolved 17 July 2007
Lifesaving › Rescue Boat › Carriage Requirement
Issued 1 May 2006 Resolved
Add third thermal protective aid to fast rescue boat. Item cleared via e-mail dated June 6, 2006. Compliance date extended to 8/1/2007 (90 days after the anniversary date) pending on-scene verification by next attending [name withheld] #2607138 for details.
Action required: 705 - Other - as specified
Due 1 August 2007
Resolved 20 August 2006
Resolution: done.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 1 May 2006 Resolved
Demonstrate proper operation of the fast rescue boat's search and navigation lights. Item cleared via e-mail dated May 9, 2006. Compliance date extended to 8/1/2007 (90 days after the anniversary date) pending on-scene verification by next attending [name withheld] #2607138 for details.
Action required: 705 - Other - as specified
Due 1 August 2007
Resolved 20 August 2006
Resolution: Done.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 1 May 2006 Resolved
Submit plans of the fixed CO2 gas system to Coast Guard MIO Europe for approval.
Action required: 705 - Other - as specified
Due 15 June 2006
Resolved 15 June 2006
Resolution: System confirmed as approved by Mitch Eanes (MSC) under approval number E1-9803087.
Lifesaving › Launching Appliances › Falls
Issued 23 July 2004 Resolved
Replace rescue boat davit falls and load test davit after renewal of falls.
Action required: 705 - Other - as specified
Due 23 August 2004
Resolved 26 July 2004
Resolution: New falls were installed and load tested this date. Load test sat.
Lifesaving › Line-Throwing Appliances
Issued 14 August 2002 Resolved
Vessel had non CG/SOLAS approved line throwing appliance onboard.
Due 3 September 2002
Resolved 14 August 2002
Resolution: Received attestation from the master ([name withheld]) that four (SOLAS approved) IKAROS #C13461P line thowing devices were placed onboard.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 3 August 2002 Resolved
Vessel had no echo depth sounder recorder. Vessel unable to retrofit to existing echo depth sounding device. New echo depth sounding device with recorder and new transducer on hull to be installed at next drydocking. LEGACY COMPONENT DESC: Echo-sounding Device Recorder
Due 29 June 2004
Resolved 23 July 2004
Resolution: Vessel installed new tansducer during dry dock.
Documentation
Issued 29 June 1999 Resolved
Prior to the carriage of cargo/inductrial personnel or sailing foriegn, vslshall have on board original Certificate of Documentation.
Condition: Unknown
Due 29 July 1999
Resolved 30 June 2000
Documentation
Issued 29 June 1999 Resolved
Provide on board vessel as per 33 CFR 151.25, an Oil Record Book.
Condition: Unknown
Due 29 July 1999
Resolved 30 June 2000
Documentation
Issued 29 June 1999 Resolved
Post all pages of Certificate of Inspection as per 46 CFR 126.240.
Condition: Unknown
Due 29 July 1999
Resolved 30 June 2000
Documentation
Issued 29 June 1999 Resolved
Provide to cognizant OCMI's representitive on board the vessel the originalCertificate of Financial Responsibilty.
Condition: Unknown
Due 29 July 1999
Resolved 30 June 2000
Lifesaving
Issued 29 June 1999 Resolved
Provide documentation that vessel Emergency Position Indicating Radio Beacon has been properly registered w/NOAA as required, and the registration decal placed on the EPIRB.
Condition: Unknown
Due 29 July 1999
Resolved 30 June 2000
Unknown
Issued 29 June 1999 Resolved
Reference USCG Marine Safety Centers approval Ltr Dtd 8APR99, Ser# E2- 9901108, items 2,4,5,6,7,9&11 must be addressed and satisfied/approved by MSC & cognizant OCMI prior to endorsement of vsl's COI Conditions of Operation as a Dual Certified OSV/Freight Vsl.
Condition: Unknown
Due 29 June 1999
Resolved 29 June 1999

Casualty record · 5

6 January 2009Routine · role: Subject to Marine Inspection · activity 3417140
21 February 2009Routine · role: Involved in a Marine Casualty · activity 3426723
7 March 2013Routine · role: Acknowledged Pollution Source · activity 4545487
15 November 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 5025363
25 March 2018Routine · role: Involved in a Marine Casualty · activity 6381488
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

HONDO RIVER (2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.