Records from 2007 to 2026. Most recent: inspection, 13 January 2026.
Documentation record
Registered dimensions (L × B × D)214.4 ft × 48.0 ft × 16.0 ft
Registered tonnagegross 1,342 / net 402
ITC dimensions (L × B × D)214.4 ft × 48.0 ft × 16.0 ft
ITC tonnagegross 1,342 / net 402
BuilderEASTERN SHIPBUILDING · PANAMA CITY, FL, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 31 March 2026 · expires 30 April 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1342 - Convention (Subpart B), Gross Ton
402 - Convention (Subpart B), Net Ton
1868 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
13 January 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8296196
29 November 2025
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8274989
20 October 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8255603
3 September 2025
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8225055
30 July 2025
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8199369
24 March 2025
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8103920
23 March 2025
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8098219
19 March 2025
Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8096433
27 February 2025
Drydock Exam · Administrative Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8085812
29 January 2024
MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7857535
6 June 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7704292
19 April 2022
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7433975
23 February 2022
MTSA/ISPS Verification · Cargo Tank Internal · Internal Structural Exam · Examination of Repairs · COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7396878
13 January 2022
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7379496
29 April 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7185366
27 April 2020
Periodic Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6944351
30 March 2020
Administrative Inspection · Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6933215
3 June 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6702606
2 March 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6364822
25 January 2018
Administrative Inspection · Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6343355
18 April 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6126991
22 March 2017
Administrative Inspection · MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6108082
14 March 2017
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6104787
6 February 2017
Administrative Inspection · MTSA/ISPS Verification · MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6083200
22 July 2016
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5952949
28 January 2016
Annual Inspection · Damage Survey · MTSA/ISPS Verification · Administrative Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5805651
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 March 2025
Resolved
The conditions of the ship and its equipment shall be maintained to ensure ship in all respects in fit to proceed to sea without danger to ship or persons on board.
Drain pipe in #1 fuel tank leading from galley to overboard was found cracked and leaking fuel. Vsl will return to Port Fourchon for investigation and repair to satisfaction of OCMI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2025
Resolved 27 March 2025
Resolution: Witnessed hydro test of pipe, all sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 29 January 2024
Resolved
A fire drill must be held on each vessel, normally on alternating weeks. It must not be held as part of the abandon-ship drill, nor immediately before or after the abandon ship drill. Vessel was conducting fire drills and abandon-ship drills consecutively on the same day. Master and crew were educated on proper practices for conducting and recording fire and abandon-ship drills.
46 CFR 131.535(a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 30 January 2024
Resolved 30 January 2024
Resolution: USCG Inspectors provided training on regulations pertaining to when to conduct fire and abandon-ship drills.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 April 2021
Resolved
Not less than one half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights complying with the requirements of paragraph 2.1.2 of the Code; 02 waterlight batteries were expired. 74 SOLAS (14) III/7.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 3 May 2021
Resolution: Vessel representative replaced expired waterlight batteries with new batteries.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 April 2021
Resolved
Tests must be conducted at periodic intervals specified by the Coast Guard to confirm that vital systems and safety features continue to operate in a safe, reliable manner; PSTPs have not been completed since 27APR20.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 6 May 2021
Resolution: Vessel rep sent PSTP report completed by Nautical Electric.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 29 April 2021
Resolved
Each vessel must be fitted with a compass suitable for the intended service of the vessel. Except aboard a vessel limited to daytime operation, the compass must be illuminated; light for the magnetic compass was inoperable.
Action required: 10 - Deficiency Rectified
Resolved 29 April 2021
Resolution: New light bulb for magnetic compass was installed prior to the completion of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2021
Resolved
Each OSV must carry lifebuoys approved under approval series 160.150; Retro-reflective tape on 03 lifebuoys were wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 3 May 2021
Resolution: New retro-reflective tape was applied to the ring buoys.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 April 2021
Resolved
The inspection for certification is made by a marine inspector to determine whether the vessel is in a safe and seaworthy condition; Exhaust for the stern thruster had a crack in it.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 May 2021
Resolution: Installed new exhaust conncetion for the stern thruster prime mover.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 27 April 2020
Resolved
Vessel compass must be fitted with a light. Vessel compass light is out. 46 CFR 130.340
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2020
Resolved 15 May 2020
Resolution: Installed new light.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 27 April 2020
Resolved
Vessel emergency generator must take on electric load in no more than 45 seconds. Emergency generator did not take on the load in 45 seconds after first try, and was tripping offline due to a blow starter circuit fuse on subsequent tries. 46 CFR 112.25-10
Action required: 10 - Deficiency Rectified
Due 27 April 2020
Resolved 27 April 2020
Resolution: Fixed on spot.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 June 2019
Resolved
The emergency fire pump continues to trip off-line on emergency generator power.
Action required: 30 - Ship detained
Resolved 5 June 2019
Resolution: The fire pump module was replaced and tested sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 June 2019
Resolved
Excessive oil in the engine room bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2019
Resolution: Oil was cleaned from the bilge.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 3 June 2019
Resolved
The 01 deck stateroom false bulkhead is no longer secured in place as designed and gives way to the HVAC room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 June 2019
Resolution: Secured the bulkhead in place.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2019
Resolved
Both of the Bridge Ring Buoy's have line for the smoke and the light that is secured to the grab line versus around the body of the ring buoy. Secure the line to the ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2019
Resolution: Removed and installed the line around the body of the buoy.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2019
Resolved
The MOB drill was poorly executed. Train and run the drill again in the presence of a Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2019
Resolution: RE-conducted the MOB drill and it was satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2019
Resolved
The stbd side tire fender is in the way of launching the rescue boat causing the rescue boat to tip and submerge the vessel in the water. Remove the tire or re-locate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 June 2019
Resolution: Moved the tire fender back 4ft and it is now out of the way of the rescue boat launching.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 January 2018
Resolved
OWS was not working properly. To be cleared by ABS when they endorse the IOPP.
Action required: 705 - Other - as specified
Due 2 February 2018
Resolved 26 January 2018
Resolution: ABS Verified operation
Navigation › Collision/Grounding Avoidance › Radar
Issued 6 February 2017
Resolved
Starboard Radar inoperable. Prove proper operation to the satisfaction of attending USCG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2017
Resolved 22 March 2017
Resolution: Witnessed proper operation of stbd radar.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 6 February 2017
Resolved
Bow Thruster Space is a Class "A" Machinery Space. A-60 boundary to mess deck above is missing 18 in X 24 in. section
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2017
Resolved 22 March 2017
Resolution: Inspected A-60 boundary in bow thruster space and saw repaired/replaced sections.
Navigation › Piloting/Steering › Maneuverability Rating
Issued 28 January 2016
Resolved
After notification that your vessel is experiencing reduced maneuberability in extended high water conditions, your vessel is restricted to Venice Dock, MM 11 until you provide a transit plan for review and approval, describing the procedures, equipment, and/or personnel that will be employed to mitigate all potential risks.
Action required: 705 - Other - as specified
Resolved 29 January 2016
Resolution: Received transit plan. Vessel allowed to proceed upriver to ship yard.
Engineering › Reduction Gearing/Clutches › Clutch Plate
Issued 28 January 2016
Resolved
#2 Port MDE engine failed to clutch in due to low lube oil pressure. Prior to movement, provide technician's report attesting to proper operation of the #2 reduction gear system.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2016
Resolved 29 January 2016
Resolution: Received tech report attesting to proper operation of port reduction gear and clutch.
Engineering › Steering Gear System › Rudder
Issued 28 January 2016
Resolved
Starboard rudder keyway damaged, vessel may proceed to Harvey Bollinger for repairs. Upon repair, prove proper operation of rudder to attending marine inspector. Vessel to repair prior to departing the lower Missiissippi River.
Action required: 705 - Other - as specified
Due 28 February 2016
Resolved 10 February 2016
Resolution: Repaired to the satisfaction of the attending marine inspector.