MAURY USCG vessel records
← All vessels

MMLP 222

Built
1968
Last inspected
9 September 2011
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 9 September 2011
…with no type recorded24
Operational controls None recorded without a removal date
Years with a record 30 calendar years (1981–2011)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-45877

Documentation record

Registered dimensions (L × B × D)175.0 ft × 50.0 ft × 11.7 ft
Registered tonnagegross 960 / net 960
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGRETNA MACHINE IRON WORKS · HARVEY LA, UNITED STATES · built 1968
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCORPUS CHRISTI, TX
Endorsements, as the file codes themcw_un
DocumentationExpired · issued 30 June 2004
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it960 - Regulatory (Subpart C or D), Gross Ton
960 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 66 inspections, each with its date, unit and type; 35 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

AUDREY HARRIS Towing Vessel · MISLE 158620 · 10 August 1999 · activity 55375

Inspection history · 66

9 September 2011 MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4142866
27 November 2010 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3900173
27 November 2010 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3902882
30 September 2010 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3859112
17 September 2009 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3595746
22 May 2009 Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3482000
23 October 2008 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3348689
9 November 2007 Hull Examination · MTSA Verification · Internal Structural Exam · COI Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3094027
11 October 2006 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2797210
11 August 2005 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2459602
20 August 2004 MTSA Verification · Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2173921
14 April 2004 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2043993
9 January 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1728019
18 December 2002 Internal Structural Exam · Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1681074
26 September 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426670
18 October 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401347
25 October 1999 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1129193
13 October 1999 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1457706
12 October 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 720076
24 September 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 63678
10 August 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 55375
17 May 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 770940
7 May 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 211077
29 April 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1130110
8 February 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 729339
4 February 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 4215
4 February 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1128941
29 September 1998 Examination of Repairs · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1420002
21 October 1997 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1111728
12 September 1997 Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1398750
26 November 1996 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1181141
20 June 1996 COI Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1428647
16 May 1996 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 760723
14 May 1996 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 207247
14 May 1996 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1422681
16 August 1995 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1455278
6 December 1994 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 442020
8 August 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 869374
21 June 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1363009
28 July 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1356364
3 August 1992 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1259766
3 July 1991 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1244829
6 June 1991 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1234715
28 June 1990 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 921717
15 November 1989 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 919968
17 October 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1347825
8 September 1989 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1036583
29 August 1989 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1203234
21 August 1989 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1200505
26 July 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1043994
12 July 1989 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1345020
29 June 1989 COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1038452
15 November 1988 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 527775
19 August 1988 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1345117
23 December 1987 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1005958
27 August 1987 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315038
2 July 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1023194
20 October 1986 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 499354
16 September 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1313438
7 August 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295066
20 February 1986 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 493373
5 July 1985 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1291347
24 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975719
8 July 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276917
3 June 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271747
10 July 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278325

Deficiency record · 35

Deck/Cargo › Holds/Tanks › Bulkhead
Issued 27 November 2010 Resolved
Found pin hole leak in on the fwd bulkhead in the #1 Port cargo tank on the raised trunk.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2010
Resolved 6 December 2010
Resolution: 3'''''''' X 40'''''''' insert on the fwd bulkhead of the #1 port and stbd cargo tanks.
Construction/Loadline
Issued 18 October 2000 Resolved
01. PROVIDE 30 YEAR GAUGINGS AS REQUIRED BY 46CFR 31.10-21 (a).
Condition: Unknown
Due 7 November 2000
Resolved 22 November 2000
Deck/Cargo
Issued 13 October 1999 Resolved
Replace #2S relief valve, #1S 8" opening and diesel tank flame screens.
Condition: Unknown
Due 13 October 1999
Resolved 13 October 1999
Construction/Loadline
Issued 13 October 1999 Resolved
Properly paint draft marks.
Condition: Unknown
Due 13 October 1999
Resolved 13 October 1999
Construction/Loadline
Issued 13 October 1999 Resolved
Replace or properly lubricate all hatch dogs so they freely rotate and properly close hatches.
Condition: Unknown
Due 13 October 1999
Resolved 13 October 1999
Navigation
Issued 13 October 1999 Resolved
Properly mount stbd sector screen.
Condition: Unknown
Due 13 October 1999
Resolved 13 October 1999
Navigation
Issued 4 February 1999 Resolved
MAKE PERMANENT REPAIRS TO STARBOARD SIDE RUNNING LIGHT HOLDER, HOLDER IS BROKEN OFF AT THE BASE AND IS HELD UP WITH LINE.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Deck/Cargo
Issued 4 February 1999 Resolved
PROVE PROPER OPERATION OF THE CLOSED GUAGING SYSTEM FOR ALL SIX TANKS. THESYSTEM CONSISTS OF INDIVIDUAL TANK LEVEL INDICATORS UTILIZING STICK_x001C_ READINGS.
Condition: Unknown
Due 14 February 1999
Resolved 8 February 1999
Deck/Cargo
Issued 29 September 1998 Resolved
PRIOR TO CONDUCTING FURTHER TRANFER OPERATIONS DETERMINE CAUSE OF DIESEL FUEL IN THE BOW RAKE.
Condition: Unknown
Due 29 September 1998
Resolved 30 September 1998
Deck/Cargo
Issued 29 September 1998 Resolved
PROVE PROPER OPERATION OF EMERGENCY SHUTDOWN OF CARGO PUMP PRIMEMOVER.
Condition: Unknown
Due 29 September 1998
Resolved 30 September 1998
Construction/Loadline
Issued 29 September 1998 Resolved
REPLACE ROMAN NUMERAL II WITH ARABIC NUMBER 2 ON ALL HULL MARKINGS TO COINCIDE WITH DOCUMENTATION CERTIFICATE.
Condition: Unknown
Due 29 September 1998
Resolved 30 September 1998
Construction/Loadline
Issued 20 June 1996 Resolved
MAKE PERMANENT REPAIRS TO BOW CENTER CLEAT.
Condition: Unknown
Due 1 July 1996
Resolved 1 July 1996
Deck/Cargo
Issued 20 June 1996 Resolved
MAKE PERMANENT REPAIRS TO #1 PORT CARGO TANK LOADING VALVE TURNING WHEEL.
Condition: Unknown
Due 1 July 1996
Resolved 1 July 1996
Deck/Cargo
Issued 20 June 1996 Resolved
MAKE PERMANENT REPAIRS TO PORT SIDE MAIN SUCTION VALVE WHEEL.
Condition: Unknown
Due 1 July 1996
Resolved 1 July 1996
Construction/Loadline
Issued 20 June 1996 Resolved
PLACE TWO MISSING HATCH COVER DOGS ON PORT SIDE VOID HATCHES.
Condition: Unknown
Due 1 July 1996
Resolved 1 July 1996
Lifesaving
Issued 20 June 1996 Resolved
RE-STENCIL "DANGER KEEP OUT" SIGNS ON CARGO HATCHES.
Condition: Unknown
Due 1 July 1996
Resolved 1 July 1996
Deck/Cargo
Issued 28 July 1993 Resolved
GAS FREE #1 PORT CARGO TANK MAKE READY FOR AIR TEST. PRODUCT IN #1 PORT VOID, AIR UP VOID TO TEST CARGO TANK FOR LEAKS, PRIOR TO LOADING ANY CARGOES.
Condition: Unknown
Due 28 August 1993
Resolved 29 July 1993
Construction/Loadline
Issued 6 June 1991 Resolved
MAKE PERMANENT REPAIRS TO 10" FRACTURE IN WAY OF THE #4 PORT WING VOID DECKKNUCKLE. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Construction/Loadline
Issued 6 June 1991 Resolved
PROPERLY MARK DRAFT MARKS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Deck/Cargo
Issued 6 June 1991 Resolved
REPLACE FLAME SCREENS IN WAY OF THE NUMBER ONE PORT AND STARBOARD HULLAGE HATCHES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Deck/Cargo
Issued 26 July 1989 Resolved
GAS FREE AND INSTALL AN INSPECTION PORT AT LEAST SIX INCHES IN DIAMETER ON TOP OF EACH DECK TANK TO THE SATISFACTION OF THE COGNIZANT [name withheld] NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 26 July 1989
Resolved 26 July 1989
Deck/Cargo
Issued 12 July 1989 Resolved
MAKE BOTH DECK TANKS AVAILABLE FOR AN INTERNAL EXAMINATION.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Deck/Cargo
Issued 12 July 1989 Resolved
PROVIDE APPROVAL PLANS FOR 2 DECK TANKS.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Lifesaving
Issued 29 June 1989 Resolved
REPAINT ALL SIGNS AND MARKINGS AND STENCILS.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Construction/Loadline
Issued 2 July 1987 Resolved
UPON DISCH OF PRESENT CARGO PROCEED DIRECTLY TO A SHIPYARD TO GAS FREE AND DRYDOCK THE VESSEL TO COMPLETE REPAIRS AS DIRECTED BY THE ATTENDING CG INSPECTOR. NO FURTHER CARGO IS TO BE LOADED UNTIL PERMANENT REPAIRS HAVE BEEN MADE. LIMITED TO RIVERS SERVICE UNTIL COMPLETION.
Condition: Unknown
Due 2 July 1987
Resolved 2 July 1987
Deck/Cargo
Issued 7 August 1986 Resolved
INSTALL 30X30 MESH FLAME SCREEN (CORROSION RESISTENT) ON #1 AND #4 PORT WING GOOSE NECK VENTS.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Deck/Cargo
Issued 7 August 1986 Resolved
PROVIDE LETTER INDICATING THAT CARGO PIPING HAS SATISFACTORILY PAST A HYDROTEST TO 1 1/2 MAWP. ALSO, THAT THE CARGO HEADER PRESSURE GAGE IS OPERABLE AND ACCURATE TO WITHIN 10 PERCENT.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Deck/Cargo
Issued 7 August 1986 Resolved
REPLACE FLEXIBLE CARGO HOSE BETWEEN PIPING AND CARGO BOOM. THIS HOSE AND CARGO BOOM PIPE MUST BE HYDRO TESTED TO 725 PSI. THE ABOVE CARGO HOSE MAY BE REMOVED FROM THE BARGE AND THE CARGO PIPING BLANKED OFF AS AN ALTERNATE REPLACEMENT.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Deck/Cargo
Issued 7 August 1986 Resolved
PROVIDE A COMPLETE AND LEGIBLE COPY OF APPROVED TRANSFER PROCEDURES ON BOARD THE VESSEL.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Deck/Cargo
Issued 7 August 1986 Resolved
PAINT "DANGER KEEP OUT" WITH CONSTASTING COLOR ON TANK DOMES.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Deck/Cargo
Issued 7 August 1986 Resolved
PROVIDE CAP FOR DO. FUEL TANK FILL. ALSO, FOR TANK'S BOTTOM DRAIN.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Navigation
Issued 7 August 1986 Resolved
PAINT LIGHT SCREENS FLAT BLACK.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Unknown
Issued 3 June 1983 Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL, IBCO 1202, DN514372
Condition: Unknown
Due 3 June 1983
Resolved 3 June 1983
Construction/Loadline
Issued 3 June 1983 Resolved
GAS FREE AND MAKE PERMANENT REPAIRS TO CRACK IN WAY OF PORT SIDE BOW KNUCKLE APPROX. 8" BELOW RAKE DECK PLATE. REPAIRS ARE TO BE COMPLETED TO
Condition: Unknown
Due 3 June 1983
Resolved 3 June 1983
Construction/Loadline
Issued 3 June 1983 Resolved
(REQUIREMENT 1 CONTINUED) THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 3 June 1983
Resolved 3 June 1983

Ownership record