Records from 1981 to 2017. Most recent: inspection, 13 June 2017.
Inspection history · 72
13 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6175000
5 October 2014
PI Safety Exam · CCSSC Examination · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4999194
30 March 2014
ISPS II Exam · CCSSC Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4825599
18 June 2012
PII Safety Exam · ISPS II Exam · CCSSC Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4347444
11 December 2011
ISPS II Exam · PII Safety Exam · CCSSC Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4205814
2 February 2011
PII Safety Exam · Ballast Water Examination · CCSSC Examination · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3937950
4 January 2011
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3919946
5 December 2010
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3904950
9 November 2010
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3887700
31 October 2010
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3881522
31 October 2010
PII Safety Exam · Ballast Water Examination · ISPS II Exam · CCSSC Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3881529
1 December 2009
Type not recorded
No type recorded · Commandant (CG-INV) · Activity 4043320
15 January 2009
MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3401428
30 March 2008
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3177529
30 January 2008
Cargo Tank Internal · Internal Structural Exam · Examination of Repairs · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3138885
12 December 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3114218
7 December 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3111426
16 February 2007
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2873260
19 January 2007
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2858615
16 February 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2586329
14 February 2006
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2584480
20 December 2004
Examination of Repairs · Cargo Tank Internal · Re-Inspection · Internal Structural Exam · MTSA Verification · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2262488
2 November 2004
Drydock Extension
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2235032
16 March 2004
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2025810
17 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1950250
21 January 2003
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1733100
4 March 2002
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1494559
11 December 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1077233
5 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1068040
22 February 2001
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1059055
11 January 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 813844
7 December 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406607
23 September 1999
Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1122043
8 January 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 797645
1 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783882
25 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 776440
28 March 1997
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1096689
13 March 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1335660
5 March 1997
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1097400
19 November 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 681793
26 September 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 108562
26 September 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 231693
5 March 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424200
6 June 1995
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 884353
1 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 757874
22 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 192358
22 April 1995
Permit to Proceed · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1454191
13 March 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449793
23 January 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 163092
3 November 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1173572
20 April 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1405535
7 December 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 849598
11 March 1993
Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1136670
20 November 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324332
2 October 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1270516
13 July 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 951088
23 December 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 957084
29 January 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 917101
23 April 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 901952
10 January 1990
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 906724
12 January 1989
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 888856
28 December 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1343167
13 January 1988
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1322605
13 January 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1336805
19 December 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314196
6 June 1986
Damage Survey
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988260
8 January 1986
Damage Survey · Examination of Repairs
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302983
17 December 1985
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985423
27 November 1985
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1305188
7 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272181
29 September 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968502
23 November 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273791
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 5 October 2014
Resolved
Arrangements should be made to satisfaction of the administration for embarkation into survival craft should include means for illuminating the stowage position. Lighting for embarkation of survival found inoperable.
Action required: 705 - Other - as specified
Due 5 November 2014
Resolved 6 October 2014
Resolution: Bulbs replaced in embarkation lighting.
Engineering › Fuel Oil Service System › Valve, Control
Issued 5 October 2014
Resolved
In a ship in which oil fuel iws used the arrangements for storage should be such as to ensure the safety of the ship and its crew. Vessel's port side fuel tank is leaking at the tanks vacuum valve creating a hazardous condition. CCSSC 13.19.2
Action required: 705 - Other - as specified
Due 5 November 2014
Resolved 7 November 2014
Resolution: Valve on port side fuel tank was replaced with new valve. No leaking.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 5 October 2014
Resolved
Each vessel must have an echo depth sounding device. Vessel's echo depth sounding device is inoperable. 33CFR164.35(h)
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2014
Resolved 6 October 2014
Resolution: Confirmed echo depth sounder is fully operational.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 5 October 2014
Resolved
The Safety Management System shall be maintained in accordance with the provisions of the International Safety Management Code. The validity of the Safety Management Certificate should be subject to at least one intermediate verification by the administration. The ship's Safety Management Certificate issued 16MAY2011 does not have an intermediate verification.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2014
Resolved 6 October 2014
Resolution: Email received containing explanation and SMC with signature confirming intermediate verification was completed 15NOV13.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 5 October 2014
Resolved
Each vessel must have marine charts of the area to be transited. Vessel does not have charts of areas transited onboard.
Action required: 705 - Other - as specified
Due 5 November 2014
Resolved 6 October 2014
Resolution: Vessel obtained and has on board charts for areas being transited (Tortola, BVI).
Navigation › Piloting/Steering › US Coast Pilot
Issued 30 March 2014
Resolved
Missing US Coast Pilot. Sailing directions, coast gurad light list, and tide tables are out of date.
Action required: 705 - Other - as specified
Due 13 April 2014
Resolved 10 April 2014
Resolution: Vessel agent provided receipt for purchase of current navigation publications.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 9 November 2010
Resolved
Owner/operator failed to prepare and submit a nontank vessel response plan IAW 33 U.S.C 1321(j)(5).
Action required: 705 - Other - as specified
Resolved 5 December 2010
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 31 October 2010
Resolved
Cargo Securing Manual missing sections.
Condition: Improper/Lack of Maintenance
Due 1 December 2010
Resolved 5 December 2010
Lifesaving › Inflatable Liferafts › Boarding Ramp/Ladder
Issued 31 October 2010
Resolved
Provide suitable hand rails for embarkation area
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 December 2010
Resolved 8 December 2010
Resolution: Hand rail welded to deck.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 January 2007
Resolved
Oily water seperator not functioning. Repair or replace unit
Action required: 705 - Other - as specified
Due 19 February 2007
Resolved 16 February 2007
Resolution: OWS repaired and tested sat.
Electrical › Electric Generation Source (service)
Issued 16 March 2004
Resolved
Port Generator, found broken wire going to electrical solenoid on engine.
Action required: 705 - Other - as specified
Due 16 March 2004
Resolved 16 March 2004
Resolution: Broken wire repaired with new wire connector and reconnected to solenoid.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 16 March 2004
Resolved
Excessive water leakage from starboard shaft packing gland
Action required: 705 - Other - as specified
Due 16 March 2004
Resolved 16 March 2004
Resolution: Tightened shaft packing, tested shaft satisfactorily
Lifesaving › Lifejacket/PFD (General)
Issued 16 March 2004
Resolved
Found two lifejackets no longer serviceable LEGACY COMPONENT DESC: Condition
Action required: 705 - Other - as specified
Due 16 March 2004
Resolved 16 March 2004
Resolution: Life jackets rejected and destroyed
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 16 March 2004
Resolved
Personal marker light defective
Action required: 705 - Other - as specified
Due 16 March 2004
Resolved 16 March 2004
Resolution: Removed and destroyed marker light
Documentation › Safety Management System
Issued 13 February 2003
Resolved
PROVIDE APPROVED AUTOMATION TEST PROCEDURES. LEGACY COMPONENT DESC: Conformity Maintenance Procedures
Action required: 705 - Other - as specified
Due 13 March 2003
Resolved 18 February 2003
Resolution: APPROVED AUTOMATION TEST PROCEDURES.
Navigation › Piloting/Steering
Issued 13 February 2003
Resolved
PROVIDE 2003 COAST PILOT. LEGACY COMPONENT DESC: US Coast Pilot
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2003
Resolved 17 February 2003
Communications › Alarms/Indicators › Fire Alarm
Issued 13 February 2003
Resolved
PROPERLY LABEL FIRE ALARM PANEL.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2003
Resolved 13 February 2003
Electrical › Lighting (emergency)
Issued 13 February 2003
Resolved
INSTALL EMERGENCY LIGHTING NEAR PORT AND STARBOARD ENGINEROOM EXITS. LEGACY COMPONENT DESC: Battery Operated Lantern
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2003
Resolved 17 February 2003
Engineering › Lubricating Oil Storage/Transfer System › Pump
Issued 13 February 2003
Resolved
PROVIDE SAFET COUPLING GUARD FOR DIRTY OIL PUMP.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2003
Resolved 13 February 2003
Electrical › Electric Supply System (service)
Issued 13 February 2003
Resolved
PROVIDE NEW BATTERY FOR EMERGENCY POWER. LEGACY COMPONENT DESC: Battery Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2003
Resolved 17 February 2003
Documentation
Issued 7 December 1999
Resolved
Provide copy of GMDSS Shore Based Maintenance Agreement.
Condition: Unknown
Due 7 December 1999
Resolved 7 December 1999
Documentation
Issued 7 December 1999
Resolved
Provide copy of USCG approved Engineering Automation Test Procedures.
Condition: Unknown
Due 7 December 1999
Resolved 7 December 1999
Navigation
Issued 5 March 1996
Resolved
INSTALL AND TEST TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR THE EQUIPMENT REQUIRED BY 47CFR80 IE: VHF AND SSB POWER SUPPLY, NAVTEX_x001C_ RECEIVER, 406 EPIRB, 9GHZ TRANSPONDER, SURVIVAL CRAFT 2 WAY RADIOS.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Fire Fighting
Issued 13 January 1988
Resolved
RENEW 2 CO2 EXTINGUSHERS IN ACCOMMONDATION SPACE WITH A-II TYPE EXTINGUSHERS.
Condition: Unknown
Due 13 January 1988
Resolved 13 January 1988
Unknown
Issued 29 September 1983
Resolved
THE FOLLOWING DEFECIENCY PERTAIN TO THE VESSEL JUANITA PATRICK, DN588735.
Condition: Unknown
Due 29 September 1983
Resolved 29 September 1983
Engineering
Issued 29 September 1983
Resolved
REPLACE BRASS FITTINGS VALVES IN FUEL OIL SERVICE PIPING.
Condition: Unknown
Due 29 September 1983
Resolved 29 September 1983