← All vessels
INDUSTRIAL DESTINY
INDUSTRIAL DESTINY is a 2006 freight ship. The Coast Guard has recorded 36 inspections since 2007, most recently in June 2026, along with 11 deficiencies and 5 operational controls, 1 with no removal date recorded.
Records from 2007 to 2026. Most recent: inspection, 16 June 2026.
- Built
- 2006
- Last inspected
- 16 June 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 11 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
Identity
9347839 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V2CD7
865605
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-865605
Inspections, by type
…with no type recorded6
Years with a record
14 calendar years (2007–2026)
The 36 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it7968 - Dead Weight, Metric Ton
12372 - Displacement, Metric Ton
7223 - Convention (Subpart B), Gross Ton
2918 - Convention (Subpart B), Net Ton
12372 - Displacement, Metric Ton
7223 - Convention (Subpart B), Gross Ton
2918 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 36
16 June 2026
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8406269
10 June 2026
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8397537
11 May 2026
Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8370780
18 December 2025
Deficiency Check · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8285108
18 October 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8254944
15 October 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8253164
8 October 2025
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8246023
4 October 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8246250
12 July 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8183736
31 March 2025
PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8102382
22 October 2023
PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7809069
22 October 2023
Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7811134
15 December 2022
Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7609466
2 December 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7603090
9 June 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7472816
8 April 2022
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7427143
24 July 2021
PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7266096
1 May 2020
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6946783
18 December 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6873383
14 December 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6873859
21 July 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6486218
16 July 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6481039
24 June 2012
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4353865
29 May 2012
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4327934
28 May 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4326004
5 January 2012
COE-Offshore
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4216445
4 December 2011
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4201196
11 August 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4107084
16 July 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4079106
6 December 2010
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3905360
13 November 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3890670
6 February 2010
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3676421
28 April 2009
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3462416
14 April 2008
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3183809
16 December 2007
ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3116444
8 March 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2883985
Deficiency record · 11
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 11 May 2026
Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code.
The company should ensure that all personnel involved in the company's Safety Management System have an adequate understanding of relevant rules, regulations, codes, and guidelines.
PSCO observed 04 crewmembers working aloft at heights exceeding 02 meters without required safety harnesses, and without filling out the required working aloft permit as required by the SMS. An internal audit report satisfactory to the OCMI must be submitted prior to clearance of deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 18 December 2025
Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7, 8, 9 OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION.
PSCO OBSERVED VDR DISPLAY SHOWING FAULT FOR FLOAT FREE NO RECORDING AND FLOAT FREE CANNOT FIND.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 18 December 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 October 2025
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions. PSCO observed a degradation of an A-60 boundary in the escape trunk.
74SOLAS(04) II-2/14.2.1.1.1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2025
Resolved
All electrical apparatus shall be so constructed and so installed as to not cause injury, when handled or touched in the normal manner. PSCO observed exposed wiring on the starboard fuel oil filter monitor.
74SOLAS(04)II-1/45.1.3
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 October 2025
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm. PSCO observed smoke detector zip-tied together, when zip-ties were removed the detector came apart exposing cut wires.
74SOLAS(04) II-2/14.2.1.1.2
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 October 2025
Resolved
Where a fixed gas fire-extinguishing system is used, openings which may admit air to, or allow gas to escape from, a protected space shall be capable of being closed from outside the protected space. PSCO observed missing fire caps from cargo holds.
74SOLAS(04) II-2/10.4.2
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 8 April 2022
Resolved
The company is responsible for ensuring that adequate resources and shore based support are provided to enable the designated person or persons to carry out their functions (3.3). The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company (10.1). In meeting these requirements, the company should ensure that: any non-conformity is reported, with its cause, if known (10.2.2), and apporpriate corrective action is taken (10.2.3).
Ship's policies and procedures manual, section 9.1 gives guidance on procedures for reporting non-conformities regarding vessel's navigational equipment. Ship's SMS maintenance form 2M-0701 provides guidance stating the activation of 25% of all detectors or call points and check that the panel responds to the alarm.
As dilineated in deficiency 02, the company failed to provide adequate resources and shore based support for making repairs to the vessel's voyage data recorder. Deficiency 03 provides objective evidence that the vessel failed in making reports of non-conformities found.
An internal audit of the ship's SMS procedures is required focusing on company responsibility and resources, and rep orting non-conformities, with possible cause, if known.
74SOLAS(20) IX/3.1, ISM Code 3.3, ISM Code 10.1, ISM Code 10.2.2, ISM Code 10.2.3
Action Taken: 105ac - Rectify deficiencies within 90 days
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 8 April 2022
Resolved
To assist in casualty investigations, ships when engaged on international voyages shall be fitted with a voyage data recorder (VDR).
PSCO observed VDR inoperable. Master provided documentation from comapny showing VDR has been inoperable since December 2021. Master has contacted company several times and was advised to "keep the problem on low profile." System remains inoperable with no current plans on how and when equipment will be rectified.
74SOLAS(20) V/20.1
Action Taken: 17ac
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 April 2022
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems.
PSCO observed 01 smoke detector in engine control room inoperable. Crew replaced smoke detector and tested operation; all satisfactory. PSCO observed successful operation of multiple smoke detectors in engine room.
74SOLAS(09) II-2/14.2.1.1.2
Action Taken: 17c, 10c.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2021
Resolved
the conditions of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed modifications made to the main diesel engine's port side at the double bottom deck of the engine room.
74 SOLAS (20) I/II(a)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.