Inspection record

Last inspected 16 June 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9347839
865605
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-865605

Documentation record

Tonnage as PSIX records it7968 - Dead Weight, Metric Ton
12372 - Displacement, Metric Ton
7223 - Convention (Subpart B), Gross Ton
2918 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

16 June 2026 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8406269
10 June 2026 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8397537
11 May 2026 Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8370780
18 December 2025 Deficiency Check · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8285108
18 October 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8254944
15 October 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8253164
8 October 2025 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8246023
4 October 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8246250
12 July 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8183736
31 March 2025 PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8102382
22 October 2023 PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7809069
22 October 2023 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7811134
15 December 2022 Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7609466
2 December 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7603090
9 June 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7472816
8 April 2022 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7427143
24 July 2021 PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7266096
1 May 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6946783
18 December 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6873383
14 December 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6873859
21 July 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6486218
16 July 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6481039

Deficiency record · 11

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 11 May 2026 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. The company should ensure that all personnel involved in the company's Safety Management System have an adequate understanding of relevant rules, regulations, codes, and guidelines. PSCO observed 04 crewmembers working aloft at heights exceeding 02 meters without required safety harnesses, and without filling out the required working aloft permit as required by the SMS. An internal audit report satisfactory to the OCMI must be submitted prior to clearance of deficiency.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2026
Resolved 10 June 2026
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 18 December 2025 Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7, 8, 9 OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. PSCO OBSERVED VDR DISPLAY SHOWING FAULT FOR FLOAT FREE NO RECORDING AND FLOAT FREE CANNOT FIND.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 18 December 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 October 2025 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions. PSCO observed a degradation of an A-60 boundary in the escape trunk. 74SOLAS(04) II-2/14.2.1.1.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2025
Resolved 10 October 2025
Resolution: A-60 Boundary in escape trunk examined to be renewed and in proper working order
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2025 Resolved
All electrical apparatus shall be so constructed and so installed as to not cause injury, when handled or touched in the normal manner. PSCO observed exposed wiring on the starboard fuel oil filter monitor. 74SOLAS(04)II-1/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2025
Resolved 10 October 2025
Resolution: Exposed wiring secured to proper junction box.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 October 2025 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm. PSCO observed smoke detector zip-tied together, when zip-ties were removed the detector came apart exposing cut wires. 74SOLAS(04) II-2/14.2.1.1.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2025
Resolved 10 October 2025
Resolution: Smoke detector was replaced and in proper working order.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 October 2025 Resolved
Where a fixed gas fire-extinguishing system is used, openings which may admit air to, or allow gas to escape from, a protected space shall be capable of being closed from outside the protected space. PSCO observed missing fire caps from cargo holds. 74SOLAS(04) II-2/10.4.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2025
Resolved 10 October 2025
Resolution: Fire caps to cargo hold condensation drain lines installed and in ready to operate condition.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 8 April 2022 Resolved
The company is responsible for ensuring that adequate resources and shore based support are provided to enable the designated person or persons to carry out their functions (3.3). The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company (10.1). In meeting these requirements, the company should ensure that: any non-conformity is reported, with its cause, if known (10.2.2), and apporpriate corrective action is taken (10.2.3). Ship's policies and procedures manual, section 9.1 gives guidance on procedures for reporting non-conformities regarding vessel's navigational equipment. Ship's SMS maintenance form 2M-0701 provides guidance stating the activation of 25% of all detectors or call points and check that the panel responds to the alarm. As dilineated in deficiency 02, the company failed to provide adequate resources and shore based support for making repairs to the vessel's voyage data recorder. Deficiency 03 provides objective evidence that the vessel failed in making reports of non-conformities found. An internal audit of the ship's SMS procedures is required focusing on company responsibility and resources, and rep orting non-conformities, with possible cause, if known. 74SOLAS(20) IX/3.1, ISM Code 3.3, ISM Code 10.1, ISM Code 10.2.2, ISM Code 10.2.3 Action Taken: 105ac - Rectify deficiencies within 90 days
Action required: 705 - Other - as specified
Due 7 July 2022
Resolved 11 June 2022
Resolution: Received documentation in regards to an internal audit of the ships sms being in compliance. Document is uploaded in misle.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 8 April 2022 Resolved
To assist in casualty investigations, ships when engaged on international voyages shall be fitted with a voyage data recorder (VDR). PSCO observed VDR inoperable. Master provided documentation from comapny showing VDR has been inoperable since December 2021. Master has contacted company several times and was advised to "keep the problem on low profile." System remains inoperable with no current plans on how and when equipment will be rectified. 74SOLAS(20) V/20.1 Action Taken: 17ac
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2022
Resolved 11 June 2022
Resolution: Received class report attesting to the successful installation of a new VDR. Document uploaded in MISLE.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 April 2022 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. PSCO observed 01 smoke detector in engine control room inoperable. Crew replaced smoke detector and tested operation; all satisfactory. PSCO observed successful operation of multiple smoke detectors in engine room. 74SOLAS(09) II-2/14.2.1.1.2 Action Taken: 17c, 10c.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 8 April 2022
Resolution: Crew replaced smoke detector and tested operation; PSCO observed all satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2021 Resolved
the conditions of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed modifications made to the main diesel engine's port side at the double bottom deck of the engine room. 74 SOLAS (20) I/II(a)
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 July 2021
Resolution: Modification was removed and verified by NKK