Records from 2008 to 2025. Most recent: inspection, 13 August 2025.
Documentation record
Registered dimensions (L × B × D)174.7 ft × 48.0 ft × 16.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)174.7 ft × 48.0 ft × 16.0 ft
ITC tonnagegross 1,111 / net 333
BuilderMASTER BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2009
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFOURCHON, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 31 March 2026 · expires 30 April 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Net Ton
333 - Convention (Subpart B), Net Ton
99 - Regulatory (Subpart C or D), Gross Ton
1111 - Convention (Subpart B), Gross Ton
983 - Dead Weight, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
13 August 2025
MARPOL Annex VI Survey · MARPOL Annex I Examination · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8209115
14 September 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8002419
14 September 2024
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8002453
22 May 2024
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7913196
26 April 2024
Drydock Exam · Cargo Tank Internal · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7901728
7 September 2023
MARPOL Annex I Examination · In-Service Inspection · MARPOL Annex VI Survey · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7787172
11 July 2022
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7503828
1 September 2021
MARPOL Annex VI Survey · Annual Inspection · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7302855
1 September 2020
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7047839
5 July 2019
MARPOL Annex I Examination · COI Inspection · Administrative Inspection · MARPOL Annex VI Survey · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6734470
17 June 2019
Administrative Inspection · Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6716369
12 September 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6540292
23 June 2017
Administrative Inspection · Periodic Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6184731
16 June 2017
Administrative Inspection · Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6177868
6 September 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5993832
24 August 2015
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5226713
7 August 2015
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5208992
30 August 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4974317
25 June 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4356712
14 June 2012
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4342690
7 September 2011
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4139505
1 September 2010
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3839925
1 December 2008
Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3372215
01 - Certificates & Documentation › 011 - Ships Certificates › Engine International Air Pollution Prevention Certificate (EIAPP)
Issued 31 January 2024
Resolved
The revised NOx Technical Code 2008 shall be applied in the certification, testing, and measurement procedures for the standards set forth in this regulation. Vessel has required EIAPP certificates for all engines on board, except the STBD Main Engine - serial number:
S2J00634
Administrative Inspection revealed that the STBD Main Engine NOx technical file contained only an EPA issued Statement of Compliance, an accepted interim method of compliance which expired 08 JAN 2012.
Provide required EIAPP certificate for Marine Inspector review prior to sailing on an international voyage.
MARPOL(73/78) VI / 13.8
Action required: 702 - Prior to embarking on international voyage
Resolved 24 April 2024
Resolution: MSU TXC received STBD main engine EIAPP Certificate / engine package documents. Uploaded under deficiencies documents tab. 835 cleared.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 7 September 2023
Resolved
A gyro-compass heading repeater, or other means, to supply heading information visually at the emergency steering position if provided. Vessels emergency steering station compass repeater was inoperable. Make compass repeater operable prior to sailing international.
CITE: 74SOLAS(2020) V/19.2.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2023
Resolved 12 September 2023
Resolution: Received technician's report and photos displaying gyro compass repeater functionality. Def Cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Engine International Air Pollution Prevention Certificate (EIAPP)
Issued 7 September 2023
Resolved
The revised NOx Technical Code 2008 shall be applied in the certification, testing, and measurement procedures for the standards set forth in this regulation. During the annual IAPP Survey, vessel crew was unable to provide EIAPP certificates for 03 installed generators with serial numbers:
CYN00416
CYN00417
CYN00433
Each generator NOx technical file contained only an EPA issued Statement of Compliance, an accepted interim method of compliance which expired 08 JAN 2012. Provide required EIAPP certificate(s) for Marine Inspector review.
CITE: MARPOL (73/78) VI/13.8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2023
Resolved 7 December 2023
Resolution: Operator has acquired 2 out of the 3 EIAPP certificates. Final certificate is in mailing process. Operator to provide final certificate for USCG once received.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 August 2022
Resolved
No OSV that carries hazardous cargoes on deck or in integral tanks may have electrical within 3 meters of space unless instrinsically safe under 46 CFR 111.105-9. Found flood that was not intrensically safe on weather deck in haz zone. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 5 August 2022
Resolved 5 August 2022
Resolution: Haz zone circle was made around flood light to ensure no hazardous cargo is stowed near the floodlight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 July 2019
Resolved
Bridge Buoy on port side is a Deck Buoy. Replace deck buoy with appropriately weighted Bridge Buoy.
74 SOLAS (14) III/7.1.3
Condition: Improper Installation
Action required: 702 - Prior to embarking on international voyage
Due 31 July 2019
Resolved 29 July 2019
Resolution: Appropriate Bridge buoy installed on port side.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 July 2019
Resolved
Watertight doors in engineering spaces require adjusting to make it watertight. Properly adjust door to make it watertight.
46 CFR 126.430
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 July 2019
Resolved 5 July 2019
Resolution: All watertight doors dogs were properly adjusted to ensure proper seating and watertight integriry.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 July 2019
Resolved
No placard present warning of that the space contains storage of CO2 in the CO2 Storage Room. Add a sign/placard depicting the cautions needed when entering the space.
46 CFR 132.340 (a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2019
Resolved 29 July 2019
Resolution: Appropriate Placard added prior to entering space.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 5 July 2019
Resolved
EPIRB not labeled with vessel name. Label the EPIRB with the NOAA registration sticker or vessel name.
46 CFR 131.890
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 5 July 2019
Resolved 5 July 2019
Resolution: EPIRB properly labeled with vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 July 2019
Resolved
Batteries on the water-lights attached to the Bridge Buoy were expired. Replace batteries on water-lights for the Bridge Buoys.
46 CFR 131.575 (d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 July 2019
Resolved 5 July 2019
Resolution: Waterlight batteries replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Fast Rescue Boats
Issued 5 July 2019
Resolved
Retro on rescue boat was worn and faded. Replace all worn and faded retro tape with SOLAS approved tape.
46 CFR 131.855(d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 July 2019
Resolved 5 July 2019
Resolution: Reto replaced on fast rescue boat on all affected areas.
Lifesaving › Launching Appliances › Davit
Issued 23 June 2017
Resolved
Vessel had not conducted satisfactory 5 year weight test for rescue boat davit. To complete satisfactory test prior to sail.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 June 2017
Resolved 27 June 2017
Resolution: Vessel provided satisfactory weight test documentation.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 6 September 2016
Resolved
Provide proof of operation of port main engine gauges in the wheelhouse.
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 6 September 2016
Resolution: Witnessed operation of the gauges prior to completion of annual inspection.
Lifesaving › Line-Throwing Appliances › Lines
Issued 6 September 2016
Resolved
Provide messanger line of 1500 ft in length and 900lbs breaking strength
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 6 September 2016
Resolution: Vessel representative sent copy of receipt to marine inspector.
Lifesaving › Rescue Boat › Propulsion Casing/Protection
Issued 6 September 2016
Resolved
Provide propeller guard for rescue bout outboard engine.
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 6 September 2016
Resolution: Vessel representative sent picture and receipt for the guard.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 25 June 2012
Resolved
Steering system is non-operational in synch. mode. Vessel shall repair to original condition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 June 2012
Resolution: Attended vessel and operated both forward and aft steering stations on the bridge in synch mode., individual steering pumps operated, NFU tested and confirmed operations visually from the bridge and Rudder Room. All Sat.
Fire Fighting › Self-contained Breathing Apparatus › Approval
Issued 25 June 2012
Resolved
Fire fighting oxygen bottle harness not approved for fire fighting. Vessel shall replace with correct fire fighting approved equipment.
Action required: 705 - Other - as specified
Due 3 July 2012
Resolved 28 June 2012
Resolution: Recived via email receipt for the purchase of two new SCBA bottles and harnesses that are fire fighting approved equipment.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 25 June 2012
Resolved
Rescue platform is too short in length to reach waters edge. Vessel shall repair rescue platform to ensure it reaches the waters edge or remove from service.
Action required: 705 - Other - as specified
Due 3 July 2012
Resolved 28 June 2012
Resolution: Attended vessel and visually verified the rescue platform had been removed. Vessel is currently equiped with rescue boat.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 25 June 2012
Resolved
Vessel missing standard discharge connection. Vessel shall ensure standard discharge connection is onboard.
Action required: 705 - Other - as specified
Due 3 July 2012
Resolved 28 June 2012
Resolution: Attended vessel and visually verified standard discharge connection is onboard.