Inspection history · 41
8 May 2026
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8369345
19 July 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8189464
9 June 2025
MARPOL Annex I Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8155600
18 October 2024
Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8022006
30 August 2024
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7992568
29 June 2024
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7945011
17 April 2024
Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7897515
25 November 2023
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7829719
11 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7806650
21 March 2023
COI Inspection · MARPOL Annex II Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7654628
28 December 2022
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7609778
14 December 2022
Internal Structural Exam · Hull Examination · Drydock Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7608402
9 December 2022
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7607064
23 June 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7233526
21 July 2020
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7012540
26 July 2018
Cargo Tank Internal · MTSA Verification · COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6490938
12 September 2017
MARPOL Annex II Examination · MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6264966
21 October 2016
MTSA Verification · Internal Structural Exam · MARPOL Annex I Examination · Examination of Repairs · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6022631
30 June 2016
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5933412
13 January 2016
MARPOL Annex II Examination · MARPOL Annex I Examination · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5797096
4 December 2014
MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5034251
30 August 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4974317
29 August 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4978586
29 January 2014
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4790927
28 January 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4790727
10 November 2013
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4763768
19 September 2013
COI Inspection · Cargo Tank Internal · Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4718549
25 September 2012
MTSA Verification · MARPOL Annex I Examination · Annual Inspection · MARPOL Annex II Examination · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4460995
15 June 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4344659
10 June 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4340624
24 February 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4252713
20 January 2012
MARPOL Annex V Examination · MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex II Examination · Deficiency Check · Periodic Inspection · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4228286
5 January 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4224211
28 October 2011
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4177743
28 October 2011
MARPOL Annex II Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4189913
18 August 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4119543
18 June 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3773499
19 January 2010
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3662771
24 June 2009
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3512854
13 May 2009
Administrative Inspection · Construction Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3488309
1 November 2007
MTSA Verification · Construction Oversight · COI Inspection · Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3170561
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 June 2025
Resolved
The applicable standards established by the ABS Marine Vessel Rules (incorporated by reference, see § 58.03-1), may be used as the standard for the design, construction, and testing of main and auxiliary machinery except as modified in this subchapter. Generator unable to shutdown due to loss of lube oil pressure as detected from sensor. Demonstrate proper alarm and shutdown of generator to the satisfaction of the marine inspector.
46 CFR 58.01-05
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 June 2025
Resolution: Recieved video evidence of proper alarm and shutdown of generator.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 1 July 2024
Resolved
All machinery associated with cargo loading, unloading, or cooling shall be capable of being shut down from a remote location. Fix shut down on STBD cargo pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2024
Resolution: Attending MI witnessed correction of deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 1 July 2024
Resolved
Except as provided in paragraph (d) of this section, no person may use any equipment listed in paragraph (c) of this section for transfer operations unless the vessel or facility operator, as appropriate, tests and inspects the equipment in accordance with paragraphs (b), (c) and (f) of this section and the equipment is in the condition specified in paragraph (c) of this section. Complete hose hydrostatic test in accordance with this section.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2024
Resolution: Attending MI witnessed correction of deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 July 2024
Resolved
Spaces containing cargo pumps, compressors, and piping are considered as equivalent to a tank vessel pumproom, and no electrical devices, except Coast Guard approved intrinsically safe devices, shall be installed in these spaces. Fix dead in cable on fwd mast, replace 04 vapor tight packing nuts on FW Delev indicator panels
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2024
Resolution: Attending MI witnessed correction of deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 1 July 2024
Resolved
Each hose also must be marked IAW this part. Mark hoses accordingly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2024
Resolved 24 July 2024
Resolution: MI Received photo evidence of the repair of deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 July 2024
Resolved
All exposed and dangerous places such as gears and machinery shall be properly protected with covers, guards or rails in order that the danger of accidents may be minimized. Provide cover for Port cargo pump prime mover turbo.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2024
Resolved 24 July 2024
Resolution: MI Received photo evidence of the repair of deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2024
Resolved
Each battery charger enclosure must meet § 111.01-9. Additionally, each charger must be suitable for the size and type of battery installation that it serves. Chargers incorporating grounded autotransformers must not be used. Replace battery charger amperage indicator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2024
Resolved 24 July 2024
Resolution: MI Received photo evidence of the repair of deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 1 July 2024
Resolved
Cargo pump relief valves shall be tested at least once each year to determine that they function satisfactorily at the pressure at which they are set to open
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2024
Resolved 11 July 2024
Resolution: MI received docuemntation stating that these pumps did not meed the relief valve requirement due to them being centrifugal.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 June 2024
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel must complete a annual inspection before it can do cargo operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2024
Resolution: MI attended vessel and perfomed annual exam.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 29 June 2024
Resolved
Oil tankers and offshore oil barges with an overall length of less than 400 feet must carry appropriate equipment and supplies for the containment and removal of on-deck oil spills of at least 7 barrels. Provide complete SOPEP equipment and inventory list IAW this part.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2024
Resolution: Attending MI witnessed correction of deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 29 June 2024
Resolved
Cargo pump pressure gage shall be tested at least once a year for accuracy
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2024
Resolved 24 July 2024
Resolution: MI Received photo evidence of the repair of deficiency.
14 - Pollution Prevention › 142 - MARPOL Annex II › Other (MARPOL Annex II)
Issued 29 June 2024
Resolved
Every ship of 150 gross tons and above certified to carry Noxious liquid substances in bulk shall carry onboard a shipboard marine pollution emergency plan for Noxious liquid substances approved the administration. MARPOL Annex II/17
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2024
Resolved 29 August 2024
Resolution: CAA amended to restrict vessel from carrying NLS cargoes.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 29 June 2024
Resolved
Each cargo tank of a tankship must be equipped with an intrinsically safe high-level alarm and a tank overfill alarm. Activate an alarm in the event of loss of power to the alarm system and Activate an alarm during the failure of electrical circuitry to the tank level sensor. Provide proof that these features are installed on system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2024
Resolution: Attending MI witnessed correction of deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 2 May 2024
Resolved
No extensive repairs to the hull or machinery which affect the safety of a vessel shall be made without the approval of the Officer in Charge, Marine Inspection (OCMI). Before such repairs are carried out, copies of plans and specifications for the work involved shall be forwarded to the OCMI. Vessel suffered a cargo pump room fire on the starboard side and must work with the local OCMI through the repair process to bring the vessel back to fit for service as required by the COI. A temporary repair plan has been submitted, reviewed, and approved by both ABS and USCG. The temporary plan must be followed in its entirety while conducting cargo operations. Any changes or modifications must have the approval of the [name withheld] final repairs are complete, they must be witnessed and verified by USCG marine inspector prior to deviating from the temporary arrangements.
Action required: 705 - Other - as specified
Due 18 May 2024
Resolved 21 October 2024
Resolution: Attending Mi witnessed the repair of the outstanding deficiency.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 28 March 2023
Resolved
Each area enclosed by the coaming required must have a mechanical means of closing each drain and scupper in the enclosed deck area. Mechanical plugs missing from all peripheral coaming.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2023
Resolved 11 April 2023
Resolution: Installed mechanical plugs in all peripheral coaming.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 21 March 2023
Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 mm (.5 in) diameter and is at least 1 in long. It must be located st the top of the flange face midway between boltholes, and in line with the bolt pattern. Port and starboard vapor control connections missing required studs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2023
Resolved 11 April 2023
Resolution: Installed required studs in vapor control connections.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 21 March 2023
Resolved
Port and starboard tank barge liquid overfill protection alarm male plug connectors missing labeling of "Connector for Barge Overflow Control System", total inductance and capacitance of the connected switches and cabling.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2023
Resolved 11 April 2023
Resolution: Installed proper box and labeling of "Connector for Barge Overflow Control System"
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 21 March 2023
Resolved
Double flame screens of 20 × 20 corrosion-resistant wire mesh with a 1/2-inch corrosion-resistant separator on a single screen of 30 × 30 corrosion-resistant wire mesh shall be fitted on all openings to atmosphere.High velocity PV valve missing flame screens on two lower drain pipe openings.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2023
Resolved 11 April 2023
Resolution: Installed 30 x 30 flame screens on high velocity p/v valve.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 July 2020
Resolved
Vessel has missed the window for the past two annual inspections. The vessel representative need to submit a request for a new COI inspection prior to resuming normal operation to carry any cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2023
Resolution: Completed COI Inspection.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 8 August 2018
Resolved
In tank vessels carrying Grade A, B, C, or D liquid cargo, cargo pumps shall be isolated from source of vapor ignition by gastight bulkheads. Starboard side cargo pump bellow was not found to be vaportight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2018
Resolved 10 August 2018
Resolution: Sector New York recieved photos of new bellow installed on barge. Deficiency cleared.
Documentation › Manuals/Policy Documentation › Procedures and Arrangements Manual (NLS)
Issued 13 January 2016
Resolved
P and A Manual on board not updated to reflect new cargoes added in 2013.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 February 2016
Resolved 30 June 2016
Resolution: Vessel provided an approval letter C1-1601143 of an updated P & A Manual.
Construction/Loadline › Hull › Bottom Plating
Issued 29 January 2014
Resolved
ABS inspected barge DBL76 grounded on January 28th 2014 and requires ABS survey before continuing operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2014
Resolution: ABS conducted survey of all ballast tanks and conducted a underwater survey. All Sat.