Records from 1992 to 2026. Most recent: inspection, 6 March 2026.
Inspection history · 59
6 March 2026
MARPOL Annex VI Survey · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8312355
3 February 2026
Vessel Attendance · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8305453
16 January 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8066994
7 June 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7932058
2 August 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7758696
25 April 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7675701
31 March 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7660583
14 October 2022
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7577385
15 August 2022
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7534303
25 March 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7418766
7 December 2020
Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7109052
16 August 2016
Deficiency Check · Administration
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5974649
15 May 2016
Administration · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5903232
26 April 2016
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5862078
7 December 2015
Deficiency Check · Administration · Marine Casualty Follow Up
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5777070
13 May 2015
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5141603
6 May 2015
Damage Survey · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5119130
1 May 2015
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5119019
9 July 2014
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4925490
16 December 2013
Industry Initiated Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4768298
25 May 2011
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4023208
29 April 2011
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4057319
18 January 2011
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3928428
18 June 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3773499
21 January 2009
Administration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3397907
14 October 2008
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3344211
4 October 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3344165
23 August 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2761100
15 June 2005
MTSA Verification · Uninspected Other
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2393398
18 January 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2276685
5 January 2003
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1731361
18 August 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1663771
19 July 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1649772
23 June 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1650731
15 May 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1633174
12 December 2001
Type not recorded
No type recorded · USCGC ADAK (WPB 1333) · USCG Northeast District (CGD-NE) · Activity 1523946
12 December 2001
Type not recorded
No type recorded · USCGC ADAK (WPB 1333) · USCG Northeast District (CGD-NE) · Activity 1523962
19 October 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 60863
20 September 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1480732
15 September 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1073519
29 August 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 142847
10 April 2001
Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1415572
26 September 2000
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 112489
14 June 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 70855
25 August 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1115475
25 February 1999
Uninspected Towing Vessel
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1388734
11 February 1999
Uninspected Towing Vessel
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1129690
15 November 1998
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 162296
7 November 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 57793
19 October 1998
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 183631
27 June 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 187267
14 April 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 59856
3 February 1997
Uninspected Towing Vessel
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1181458
21 November 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 4262
29 May 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1088266
26 January 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 26536
1 January 1995
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 146694
20 April 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 644861
9 July 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 67433
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 March 2026
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. [...] If a dedicated storage cabinet is provided it must be secured to the vessel so that it does not move and must be either:
(1) A flammable liquid storage cabinet that satisfies UL 1275 (incorporated by reference, see § 136.112 of this subchapter); or (2) A flammable liquid storage cabinet that satisfies FM Approvals Standard 6050 (incorporated by reference, see § 136.112 of this subchapter); or (3) Another suitable steel container that provides an equivalent level of protection.
Vessel has a plastic paint storage locker on deck, O/O to shift stored products to acceptable location or supply compliant storage cabinet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2026
Resolved 15 April 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Vessel BNWAS had a DC Power Failure. Vessel to investigate and rectify battery issue.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2026
Resolved 15 April 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 January 2025
Resolved
Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Signage was missing for fuel shut off in the crew galley space.
46CFR143.260(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2025
Resolved 27 January 2025
Resolution: Received photo evidence of of the Emergency Fuel Shut Off plaque that was installed in the crew galley space per the deficiency noted in 46 CFR 143.260 (e)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 March 2023
Resolved
A towing vessel that is exposed to salt water more than 6 months in any 12 month period must undergo a drydock and internal structural examination at least twice every 5 years, nor to exceed 36 months. MARIE H did not undergo drydock exam and ISE IAW due date of 31MAR2023 on vessel's COI. Complete credit drydock and ISE prior to towing operations.
Cite: 46CFR137.300, 46CFR137.302
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 April 2023
Resolved 15 August 2023
Resolution: Documentation for drydock reviewed. Accepting ABS loadline survey as required drydock inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 7 April 2022
Resolved
Line throwing appliance - 2 lines and charges were onboard at time of inspection. Acquire and maintain 4 lines and 4 charges within 30 days.
46 CFR 141.385
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2022
Resolved 12 October 2022
Resolution: Vessel representative provided photographic evidence of four line throwing appliances.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 April 2022
Resolved
Hatch gasket on 2nd deck starboard side found not to maintain watertight integrity. Repair within 30 days.
46 CFR 140.605 (b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2022
Resolved 15 August 2022
Resolution: Hatch gasket was replaced. Hatch now maintains watertight integrity.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 April 2022
Resolved
Both ships start air receiver's relief valves found not to relieve pressure at less than 10% above MAWP. Demonstrate relief valves relieve at proper set point within 30 days.
46 CFR 143.300 (a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2022
Resolved 15 August 2022
Resolution: Pressure relief valve replaced; proper relief within 10% of MAWP was demonstrated.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 25 March 2022
Resolved
Vessel was unable to get underway to conduct drills at time of inspection. Make vessel available to conduct drills within 30 days.
46 CFR 136.200(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2022
Resolved 7 April 2022
Resolution: Vessel was made available to conduct drills, all SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 March 2022
Resolved
Make vessel available for inspection of all machinery and navigational equipment within 30 days.
46 CFR 136.200(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2022
Resolved 8 April 2022
Resolution: Vessel provided evidence of alarm testing in 2020 from a 3rd party testing service. Per regulation vessel is not required to test at each annual.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2022
Resolved
Forward breaker panel in wheelhouse was found to have an opening in the face, cover unused openings within 30 days.
46 CFR 143.560(a)(2)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2022
Resolved 8 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2022
Resolved
Daisy chaining of extension cords is taking place in wheelhouse, potentially overloading 120V receptacles/circuits. Rectify unsafe condition within 30 days.
46 CFR 143.205(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2022
Resolved 7 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2022
Resolved
Wires were found to be terminating throughout wheelhouse space, covered with electrical tape. Correct unsafe condition within 30 days.
46 CFR 143.205(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2022
Resolved 7 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2022
Resolved
Ring buoy located at portside wheelhouse found to have flashing light duct taped to hand rail, not allowing ring buoy to be easily thrown. Deficiency rectified upon discovery.
46 CFR 136.200(b)(2)&(3)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 April 2022
Resolved 25 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2022
Resolved
Starboard side wheelhouse ring buoy missing, replace ring buoy in proper location within 30 days.
46 CFR 141.360(b)(2)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2022
Resolved 8 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 25 March 2022
Resolved
One single line throwing apparatus was found onboard with no spares and no extra shots provided. Acquire and maintain an auxiliary line.
46 CFR 141.385
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2022
Resolved 8 April 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 March 2022
Resolved
Acquire and maintain unexpired items in first aid kit within 30 days.
46 CFR 140.435
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2022
Resolved 7 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 25 March 2022
Resolved
Acquire and maintain full complement of immersion suits onboard within 30 days.
46 CFR 141.350
Action required: 60 - Rectify deficiencies prior to movement
Due 25 April 2022
Resolved 7 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 25 March 2022
Resolved
Distribute complement of life jackets and immersion suits throughout vessel into applicable spaces; i.g. operating stations & living quarters. Rectify within 30 days.
46 CFR 141.340 & .350
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 25 April 2022
Resolved 7 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2022
Resolved
Demonstrate means of testing reverse power relay to prevent motorization of paralleled generator. Reverse power relay or interlock to prevent paralleling is required. Rectify within 30 days.
46 CFR 143.555(a)(2)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 25 April 2022
Resolved 7 April 2022
Resolution: O/o hired marine electrician to install interlock to prevent paralleling of generators. Interlock is internal to bus tie breakers. Syncroscope removed as well.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 March 2022
Resolved
Simple, complete operating instructions not provided at CO2 operating station. Post or provide clear instructions at CO2 operating station within 30 days.
46 CFR 136.10
46 CFR 95.16-50(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2022
Resolved 15 August 2022
Resolution: Simple operating instructions were posted at the CO2 operating station.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 March 2022
Resolved
Goose necks/tank vents/space vents on deck are not labeled. Effectively label vents on deck within 30 days.
46 CFR 143.250 (c)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2022
Resolved 15 August 2022
Resolution: All goose necks, tank vents, and space vents have been appropriately marked with space and service.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 25 March 2022
Resolved
Provide means of locking/disabling actuation of MSD effluent overboard discharge line at last valve. Rectify within 30 days.
33 CFR 159.7
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2022
Resolved 7 April 2022
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 25 March 2022
Resolved
Provide evidence that galley renovation will not effect weight change in excess of 2% to determine whether stability test must be conducted. Provide prior to cargo operations.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 April 2022
Resolved 7 April 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 March 2022
Resolved
Each carbon dioxide or clean agent fire extinguishing alarm must be conspicuously marked: "WHEN ALARM SOUNDS VACATE AT ONCE. CARBON DIOXIDE OR CLEAN AGENT BEING RELEASED.". Sign missing.
46 CFR 136.10
46 CFR 78.47-9
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2022
Resolved 15 August 2022
Resolution: A sign with the above verbiage has been conspicuously posted in the engine room.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 March 2022
Resolved
Each space storing CO2 cylinders shall be posted with - "CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERNING. A HIGH CONCENTRATION CAN OCCURE IN THIS AREA AND CAN CAUSE SUFFOCATION.". Sign missing.
46 CFR 136.10
46 CFR 78.47-11(A)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2022
Resolved 15 August 2022
Resolution: Sign with the above verbiage has been conpsicuously posted in the engine room.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 7 December 2020
Resolved
Replace missing WTD winch engine room to aft deck.
46 CFR 137.220
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 7 December 2020
Resolved
Replace missing vent closures 02 located FWD main deck Port, and 01 Main Deck Amidship STBD.
46 CFR 137.220 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 22 March 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 December 2020
Resolved
Install fire hose at STBD Main Deck fire station.
46 CFR 142.235.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 December 2020
Resolved
Provide third party report attesting to proper operation or demonstrate proper operation of engine alarms required by 46 CFR 143.230.
46 CFR 143.230
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 22 March 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 December 2020
Resolved
Make watertight unused cable penetrations on aft bulkhead of winch engine space.
46 CFR 143.230
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 22 March 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 December 2020
Resolved
Provide annual service report for servicing of fixed CO2 system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 26 March 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 December 2020
Resolved
Make serviceable extinguished anchor light.
46 CFR 140.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 22 March 2021
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 7 December 2020
Resolved
Mount fire axe on exterior of vessel as required by 46 CFR 142.227.
46 CFR 142.227
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 22 March 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 December 2020
Resolved
Vessel required to maintain Declaration of Inspection for last 30 days, retain and provide proof of retention.
33 CFR 156.150 (f)
Action required: 703 - Prior to bunkering operations
Resolved 22 March 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 December 2020
Resolved
Label audible alarm indicating discharge of CO2 as required by 46 CFR 78.47-9.
46 CFR 78.47-9
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 22 March 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 December 2020
Resolved
Permanently wire battery chargers on aft engine room bulkhead into electrical system.
46 CFR 143.400
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 22 March 2021
08 - Alarms › N/A - No Subsystem › General alarm
Issued 7 December 2020
Resolved
Replace engine room placard for general alarm as required and described in 46 CFR 143.225 (a)(3).
46 CFR 143.225 (a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 22 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 7 December 2020
Resolved
Label emergency fwd and aft emergency exits on both sides as required and described in 46 CFR 144.150(f).
46 CFR 144.150(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 22 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 7 December 2020
Resolved
Label watertight doors and hatches on both sides as required and described in 46 CFR 144.150(f).
46 CFR 144.150(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 22 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 December 2020
Resolved
Mark life rings with name of vessel as required by 46 CFR 141.360 (b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 22 March 2021
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 7 December 2020
Resolved
Provide updated compass deviation chart for magnetic compass.
46 CFR 140.725
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 22 March 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 December 2020
Resolved
Provide day shapes as required by 46 CFR 140.720.
46 CFR 140.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 22 March 2021
Navigation
Issued 10 April 2001
Resolved
REPAIR CRACK IN STEERING ARM JOINING PIN._x001C_ CLEARED VIA FAX RECIEVED 11APR01. SEE NARRATIVE SUPPLIMENT.
Condition: Unknown
Due 16 April 2001
Resolved 16 April 2001
Accommodation/Occupational Safety
Issued 10 April 2001
Resolved
MSD NOT MOUNTED TO MANUFACTURERS SPECIFICATION. CLEARED VIA FAX RECIEVED 11APR01.
Condition: Unknown
Due 16 April 2001
Resolved 16 April 2001
Electrical
Issued 10 April 2001
Resolved
INSTALL RUBBER ELECTRICAL MATTING BEHING SWITCHBOARD IN ENGINE ROOM._x001C_ CLEARED VIA FAX RECIEVED 11APR01
Condition: Unknown
Due 16 April 2001
Resolved 16 April 2001
Lifesaving
Issued 25 February 1999
Resolved
INSTALL METAL PAINT LOCKER WITH EXTINGUISHER NEXT SHIPYARD PERIOD. 30JUN99
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999