Records from 2007 to 2025. Most recent: inspection, 17 August 2025.
Documentation record
Registered dimensions (L × B × D)300.0 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,632 / net 1,632
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2007
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1632 - Simplified, Gross Ton
1632 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
17 August 2025
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8219328
10 May 2022
MTSA Verification · COI Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7443828
30 May 2018
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6537880
7 April 2017
Drydock Exam · Internal Structural Exam · Cargo Tank Internal · MTSA Verification · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6121979
4 April 2016
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5868258
11 March 2015
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5749998
25 July 2014
Administrative Inspection · Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4938950
13 December 2013
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4768966
27 April 2012
MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4296564
10 December 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4205674
6 January 2011
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3959936
16 April 2010
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3717141
19 January 2010
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3692664
14 January 2009
Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3393986
30 December 2008
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3390785
8 April 2008
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3179863
6 February 2008
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3142694
13 April 2007
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2908183
22 March 2007
Cargo Tank Internal · Hull Examination · MTSA Verification · Construction Oversight · Internal Structural Exam · Initial Certification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2892565
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 March 2007
Resolved
Noted improper crimp connectors on wires in terminal block distribuition box. Crimp connectors immediately changed out by yard personnel.
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 22 March 2007
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 22 March 2007
Resolved
Sheet metal screws for screen on ERL relief valve for VCS were missing. Yard personnel provided screws and installed.
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 22 March 2007
13 April 2007Routine · role: Involved in a Marine Casualty · activity 2908183
30 December 2008Routine · role: Involved in a Marine Casualty · activity 3390785
10 December 2011Routine · role: Involved in a Marine Casualty · activity 4205674
13 December 2013Routine · role: Subject to Marine Inspection · activity 4768966
17 August 2025Routine · role: Involved in a Marine Casualty · activity 8219328
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source:
IIR, through 2026.