LITTLE LADY II

LITTLE LADY II is a 2007 passenger vessel (inspected). The Coast Guard has recorded 39 inspections since 2007, most recently in April 2026, along with 62 deficiencies, 1 operational control and 5 casualty investigations between 2009 and 2022.

Records from 2007 to 2026. Most recent: inspection, 1 April 2026.

Built
2007
Last inspected
1 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE7746
869085
Flag
UNITED STATES
367397090
Maury page id
psix-869085

Inspections, by type

…with no type recorded4
Years with a record 18 calendar years (2007–2026)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.9 ft × 22.0 ft × 6.0 ft
Registered tonnagegross 27 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA TAXI CATAMARANS, INC. · OPA LOCKA, FL, UNITED STATES · built 2007
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeShip
Hull configurationTwin Hull
Hailing portJERSEY CITY, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Net Ton
27 - Simplified, Gross Ton
38 - Displacement, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE7746MMSI 367397090 · active · compulsorily equipped · granted 8 February 2019, expires 27 February 2029
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISS NEW JERSEY Passenger (Inspected) · MISLE 365120 · 12 December 2019 · activity 6873280

Inspection history · 39

1 April 2026 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8333641
12 June 2025 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8157607
25 April 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8120253
12 June 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7932433
13 June 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7713809
6 April 2023 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7662329
13 June 2022 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7469898
13 May 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7449888
3 May 2022 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7443273
30 September 2021 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7448517
3 March 2021 Examination of Repairs · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7149348
24 July 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7014820
12 December 2019 Damage Survey · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6872828
12 December 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6873280
17 July 2019 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6752967
7 March 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6751147
23 January 2019 Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6614167
22 January 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6626408
13 June 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6444467
3 January 2018 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6331954
29 June 2017 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6190394
13 February 2017 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6087175
19 August 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5977573
20 July 2016 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5946793
15 July 2015 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5190164
13 August 2014 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4953400
9 July 2012 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4372871
13 September 2011 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4144071
13 July 2009 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3533724
9 April 2009 Damage Survey · Examination of Repairs · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3449236
3 March 2009 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3426998
23 January 2009 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3398778
25 November 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3369444
17 October 2008 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3346676
4 October 2007 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3072762
30 May 2007 Deadweight Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2946465
17 May 2007 Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2952507
15 May 2007 MARPOL Annex V Examination · Hull Examination · Initial Certification · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2931350
9 January 2007 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2852615

Deficiency record · 62

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 April 2026 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Placard for life jacket model # S225RT is missing, post placards.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 8 April 2026
Resolution: Rectified.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 April 2026 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests. Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly inspections of fire extinguishers were not completed and logged.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 8 April 2026
Resolution: Monthly inspection of fire extinguishers were completed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 April 2026 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Waste receptacle is constructed of plastic.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 2 April 2026
Resolution: Rectified, other means are provided to prevent a fire.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 1 April 2026 Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. Replace stbd side broken light fixture in the lazarette space.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 18 May 2026
Resolution: Deficiency rectified. Light fixture and connection were replaced with new connection and light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 April 2026 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child life preservers were not stowed separate from adult life jackets. Ensure child life jackets are stowed separately from adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 2 April 2026
Resolution: Barrier between child and adult life jackets.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 1 April 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wire found in port outboard side of Generator. Repair or remove wires.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 8 April 2026
Resolution: Dead end wire removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 June 2025 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) carrying not more than 49 passengers other than a ferry, provided that: (7) a positive shut off valve is installed at th e hull penetration. The following sea cocks were observed to be seized: Port: Forepeak, Generator Space, Fuel Tank Void, Engine Compartment, Lazarette. STBD: Forepeak, Laz. Additionally the STBD Engine compartment is unable to completely close due to proximity to bilge piping and requires modification to properly close. 46 CFR 182.520 (e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 23 June 2025
Resolution: MI observed all listed seacocks were replaced. All appeared in good order.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protected devices must be in satisfactory condition. Existing penetration in STBD forepeak is not permanently capped/terminated. 46 CFR 176.830 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 23 June 2025
Resolution: Firestop was placed in the STBD Forepeak
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 June 2025 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. STBD Engine fuel shutoff valve shielding is wasted and not providing proper shielding. 46 CFR 182.455 (b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 23 June 2025
Resolution: Vessel replaced the shielding for both Port and Stbd Fuel Shutoff valve
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 12 June 2024 Resolved
A vessel with a power driven main steering gear must be provided with the following: an independent rudder angle indicator at the operating station. MI observed in port side steering space, an emergency steering station with no rudder angle indicator. Vessel must install means of providing rudder angle indcator at that operating station. 46 CFR 182.610
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 14 June 2024
Resolution: Recieved email with photo confirmation of double clamping for bilge hoses. Additionally receieved receipt of rudder angle indcator system for e-steering position. Qualified MI reviewed photos and accepted.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 12 June 2024 Resolved
In systems and appliances where flexible hoses are permitted to be clamped, double hose clamping is required where practible. MI observed bilge dewatering system with flex hoses in both port and starboard steering flat without double clamping. Hoses must be double clamped. 46 CFR 182.410(d)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 14 June 2024
Resolution: Received photo evidence of double clamping of hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 May 2022 Resolved
The construction and arrangement vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull,protection against fire, means of escape in case of sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. On 03MAY2022, vessel reported loss of power/loss of propulsion. Prior to passenger operations, vessel shall submit repair plan for all impacted equipment, provide technician report attesting to operation of impacted machinery, and provide causal analysis report. 46 CFR 177.2100, 701c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2022
Resolution: A USCG Marine Inspector attended LITTLE LADY II (1194797) earlier today (13JUN2022) and cleared the remaining deficiency. Operator sent a satisfactory causal analysis/technician report. MI documented reported under vessel’s profile. MI witnessed satisf
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 24 July 2020 Resolved
Fire Insulation is missing on overhead hatches in port and starboard enginge rooms; insulation is not fastened to overhead in port generator room. 46CFR177.410(c)(4)
Action required: 705 - Other - as specified
Due 27 July 2020
Resolved 27 July 2020
Resolution: Received email and pictures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 December 2019 Resolved
replace clutch circuit board and prove proper operation of the control system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2019
Resolution: Vessel made in kind replacement of the clutch relay circuit card and proved proper operation.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 December 2019 Resolved
fix the railing and fiberglass attachment point.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2019
Resolution: Vessel made proper repairs to the stbd fwd aluminum rail, all sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 July 2015 Resolved
AM01: Repair/replace STBD high level alarm light in lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2015
Resolution: Alarm tested- SAT.
Fire Fighting › Nozzles › Approval
Issued 15 July 2015 Resolved
AM02: Replace all fire hose nozzles with approved type. Current nozzles are not approved plastic type.
Due 17 July 2015
Resolved 15 July 2015
Resolution: Nozzles replaced with approved type.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 August 2014 Resolved
Prove proper operation of STBD generator fire boy shutdown and override.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 August 2014
Resolved 15 August 2014
Resolution: Witnessed correct operation of the STBD generator fire boy shutdown and override.
Fire Fighting › Fire Pumps › Pressure
Issued 13 August 2014 Resolved
Replace pressure guage on port fire pump.
Action required: 705 - Other - as specified
Due 27 August 2014
Resolved 15 August 2014
Resolution: Witnessed new pressure guage on port bilge pump and tested operation.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 13 August 2014 Resolved
Replace main exhaust hose on port engine.
Action required: 705 - Other - as specified
Due 27 August 2014
Resolved 15 August 2014
Resolution: Main exhaust hose on port engine was replace with appropiate hose.
Engineering › Bilge Water Management System › Pump
Issued 13 August 2014 Resolved
Prove proper operation of second means for bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2014
Resolution: Witnessed proper operation of the fire pump. Pump was able to get to 75 psi with steady stream. Upon closing water hose nozzle, new relief valve set for 60 psi relieved built up pressure and worked perfectly.
Construction/Loadline › Hull › Hull Plating
Issued 9 July 2012 Resolved
Properly renew port bow fiberglass damage at next drydock.
Action required: 705 - Other - as specified
Due 15 April 2013
Resolved 15 April 2013
Resolution: Vessel made repairs to bow fiberglass.
Stability › Incline Test › General
Issued 9 July 2012 Resolved
In accordance with AAWPP vessels stability is reduced to 131 of which 128 may be passengers when operating on a rivers route.
Action required: 705 - Other - as specified
Resolved 3 October 2012
Resolution: Received Stability letter from MSC.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 September 2011 Resolved
Stbd generator does not shut down when Fireboy system automatically operates. Prove proper operation of stbd generator Fireboy system.
Action required: 705 - Other - as specified
Due 21 September 2011
Resolved 20 September 2011
Resolution: Fireboy system is operating properly.
Communications › Alarms/Indicators › Fire Alarm
Issued 13 September 2011 Resolved
Audible alarm on stbd engine Fireboy system is inoperable. Prove proper operation of audible alarm.
Action required: 705 - Other - as specified
Due 21 September 2011
Resolved 20 September 2011
Resolution: Fireboy alarm system is operating properly.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 13 September 2011 Resolved
Electrical cables are bundled with fuel hoses in port and stbd generator room. Re-route cables separetely from hoses.
Action required: 705 - Other - as specified
Due 21 September 2011
Resolved 20 September 2011
Resolution: Cables were re-routed.
Navigation › Piloting/Steering › Magnetic Compass
Issued 13 July 2009 Resolved
Replace light on magnetic compass.
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 17 July 2009
Resolution: Light replaced and operational. Deficiency cleared.
Lifesaving › Hand Flares › Quantity
Issued 13 July 2009 Resolved
Provide one red hand flare.
Action required: 705 - Other - as specified
Resolved 17 July 2009
Resolution: Additional red hand flare provided. Deficiency cleared.
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 July 2009 Resolved
Replace port side raw water intake hose.
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 17 July 2009
Resolution: Intake hose replaced. Deficiency cleared.
Engineering › Steering Gear System › Power Unit
Issued 13 July 2009 Resolved
Prove proper operation of vessel's steering system and conduct man overboard drill.
Action required: 705 - Other - as specified
Resolved 17 July 2009
Resolution: Witnessed satisfactory drill and proper operation of steering system from void. Deficiency cleared.
Documentation › Certificates/Documents › FCC SSL
Issued 17 October 2008 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 28 March 2009
Resolved 9 March 2009
Personnel › Training › First Aid/CPR
Issued 17 October 2008 Resolved
Provide training and certification for CPR and Basic First Aid for 50% of the ships crew.
Action required: 705 - Other - as specified
Due 28 March 2009
Resolved 9 March 2009
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 October 2008 Resolved
Cleanout console underneath the pilot house controls and remove all trash and all other nonessential equipment.
Action required: 705 - Other - as specified
Due 17 November 2008
Resolved 25 November 2008
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 17 October 2008 Resolved
Provide a life jacket donning instruction placard on the upper passenger deck.
Action required: 705 - Other - as specified
Due 17 November 2008
Resolved 25 November 2008
Stability › Weathertight Integrity › General
Issued 14 June 2007 Resolved
Submit plans to Sector New York delaining how the port and stbd doors will be made weathertight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2007
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 14 June 2007 Resolved
Submit plans to Sector New York detaining the structural fire protection for the machinery spaces IAW 46CFR177.410(c)(4).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 June 2007 Resolved
Provide shields in way of the port & stbd generators and port & stbd main engine fuel shut off valves at the tank IAW 46CFR182.455(a)(4).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 June 2007 Resolved
Ensure 2nd deck stern rail meets the height requirement in 46CFR179.900. (39.5")
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 June 2007 Resolved
Ensure rail port fwd main deck meets the height requirement in 46CFR177.900.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 14 June 2007 Resolved
Install the tank (nozzle) in way of the port and stbd fixed fire extinguishers in the machinery spaces IAW the manufactures instructions (nozzles must face the opposite bulkhead).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 June 2007 Resolved
Provide corrosion resistant clip in way of ring buoy floating waterlight lanyard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2007
Fire Fighting › Means of Escape › Escape Route Signs
Issued 14 June 2007 Resolved
Mark instructions for opening the emergency escape hatch on the main deck from the inside.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2007
Fire Fighting › Fixed Fire Detection System › Approval
Issued 7 June 2007 Resolved
Submit plans for the fire and smoke detection system IAW 46CFR177.202(b)(6)(iii) for review and approval by the local OCMI.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 June 2007 Resolved
In accordance with 46CFR177.202(b)(5) submit a plan showing the lifesaving equipment locations and installation for review and approval by the local OCMI.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Fire Fighting › Ventilation Systems › Ducts
Issued 7 June 2007 Resolved
In accordance with 46CFR177.202(b)(3)(iii) submit plans of the ventilation systems onboard the vessel (natural and mechanical) for review and approval by the local OCMI.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 7 June 2007 Resolved
In accordance with 46CFR177.202(b)(6)(v) submit plans showing the portable fire extinguishers types, sizes, & locations for review and approval by the local OCMI.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 7 June 2007 Resolved
In accordance with 46CFR181.420(a)(4) have the manufacturer's instructions for the pre engineered fixed fire extinguishing system available for review during the COI.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 7 June 2007 Resolved
In accordance with 46CFR177.202(b)(10) provide proof of the marine sanitations device is of the approved type.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 June 2007 Resolved
Submit as built amendments of the following plans for local approval: 1) AC Distribution - Helm. 2) DC Helm Station Encl 6. 3) AC Helm Station Encl 7.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 6 June 2007 Resolved
Provide a framed chart of the smoke detector locations IAW 46CFR181.400(c)(2) - 46CFR76.33-20.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 6 June 2007 Resolved
The wire for the smoke detector heads from the main deck DC panel room to the detector heads is solid conductor. Replace replace the solid conductor wire with stranded wire IAW 46CFR183.340(b)(1).
Action required: 705 - Other - as specified
Resolved 18 July 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 May 2007 Resolved
Make modifications to the electrical as needed to match the approved plans.
Action required: 705 - Other - as specified
Resolved 6 June 2007
Resolution: Re-issued a detailed requirement this date.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 18 May 2007 Resolved
Prove proper operation of the engine control system IAW 46CFR184.620(c). A loss of power to the propulsion control system must not result in an increase in shaft speed.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 18 May 2007 Resolved
Provide independent means of for shutting down the propulsion engines IAW 46CFR620(b).
Action required: 705 - Other - as specified
Resolved 18 July 2007
Engineering › Fuel Oil Service System › Valve
Issued 18 May 2007 Resolved
Install fuel shut off valves at the propulsion engines and generators IAW 46CFR182.455(b)(4).
Action required: 705 - Other - as specified
Resolved 18 July 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 May 2007 Resolved
Submit electrical load analysis for review to the local [name withheld] 46CFR177.202(b)(4)(ix).
Action required: 705 - Other - as specified
Resolved 18 July 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 15 May 2007 Resolved
Mark emergency escape hatch on upper deck "Emergency Escape Keep Clear" IAW 46 CFR 185.606.
Action required: 705 - Other - as specified
Due 18 August 2007
Resolved 19 July 2007
Construction/Loadline › Structures › Superstructure
Issued 15 May 2007 Resolved
Address/repair leaks in main deck windows and overhead.
Action required: 705 - Other - as specified
Due 18 August 2007
Resolved 19 July 2007
Documentation › Certificates/Documents › FCC SSL
Issued 15 May 2007 Resolved
Provide FCC Safety Certificate onboard vessel.
Action required: 705 - Other - as specified
Due 18 August 2007
Resolved 19 July 2007
Fire Fighting › Firemans Outfit › Axe
Issued 15 May 2007 Resolved
Mark fire axe with vessel's name.
Action required: 705 - Other - as specified
Due 18 August 2007
Resolved 19 July 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 15 May 2007 Resolved
Mark stairtower leading to upper deck with max passenger capacity in accordance with 46 CFR 185.604(g).
Action required: 705 - Other - as specified
Due 18 August 2007
Resolved 19 July 2007
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 May 2007 Resolved
Provide Certificate of Documentation onboard vessel.
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 9 October 2007

Casualty record · 5

21 August 2009Routine · role: Involved in a Marine Casualty · activity 3572729
19 August 2016Routine · role: Involved in a Marine Casualty · activity 5977573
22 January 2019Routine · role: Involved in a Marine Casualty · activity 6626408
12 December 2019Routine · role: Involved in a Marine Casualty · activity 6873280
13 May 2022Routine · role: Involved in a Marine Casualty · activity 7449888
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.