Records from 2009 to 2026. Most recent: inspection, 1 April 2026.
Documentation record
Registered dimensions (L × B × D)64.9 ft × 22.0 ft × 6.0 ft
Registered tonnagegross 27 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA TAXI CATAMARANS, INC. · OPA LOCKA, FL, UNITED STATES · built 2007
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeShip
Hull configurationTwin Hull
Hailing portJERSEY CITY, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Net Ton
27 - Simplified, Gross Ton
38 - Displacement, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 24
1 April 2026
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8333641
12 June 2025
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8157607
25 April 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8120253
12 June 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7932433
13 June 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7713809
6 April 2023
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7662329
13 June 2022
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7469898
13 May 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7449888
3 May 2022
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7443273
30 September 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7448517
3 March 2021
Examination of Repairs · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7149348
24 July 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7014820
12 December 2019
Damage Survey · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6872828
12 December 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6873280
17 July 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6752967
7 March 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6751147
23 January 2019
Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6614167
22 January 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6626408
13 June 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6444467
3 January 2018
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6331954
29 June 2017
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6190394
13 February 2017
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6087175
19 August 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5977573
20 July 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5946793
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 April 2026
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Placard for life jacket model # S225RT is missing, post placards.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 8 April 2026
Resolution: Rectified.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 April 2026
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests. Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly inspections of fire extinguishers were not completed and logged.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 8 April 2026
Resolution: Monthly inspection of fire extinguishers were completed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 April 2026
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Waste receptacle is constructed of plastic.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 2 April 2026
Resolution: Rectified, other means are provided to prevent a fire.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 1 April 2026
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. Replace
stbd side broken light fixture in the lazarette space.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 18 May 2026
Resolution: Deficiency rectified. Light fixture and connection were replaced with new connection and light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 April 2026
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child life preservers were not stowed separate from adult life jackets. Ensure child life jackets are stowed separately from adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 2 April 2026
Resolution: Barrier between child and adult life jackets.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 1 April 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wire found in port outboard side of Generator. Repair or remove wires.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 8 April 2026
Resolution: Dead end wire removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 June 2025
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) carrying not more than 49 passengers other than a ferry, provided that: (7) a positive shut off valve is installed at th e hull penetration. The following sea cocks were observed to be seized: Port: Forepeak, Generator Space, Fuel Tank Void, Engine Compartment, Lazarette. STBD: Forepeak, Laz. Additionally the STBD Engine compartment is unable to completely close due to proximity to bilge piping and requires modification to properly close.
46 CFR 182.520 (e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 23 June 2025
Resolution: MI observed all listed seacocks were replaced. All appeared in good order.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protected devices must be in satisfactory condition. Existing penetration in STBD forepeak is not permanently capped/terminated.
46 CFR 176.830 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 23 June 2025
Resolution: Firestop was placed in the STBD Forepeak
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 June 2025
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. STBD Engine fuel shutoff valve shielding is wasted and not providing proper shielding.
46 CFR 182.455 (b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 23 June 2025
Resolution: Vessel replaced the shielding for both Port and Stbd Fuel Shutoff valve
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 12 June 2024
Resolved
A vessel with a power driven main steering gear must be provided with the following: an independent rudder angle indicator at the operating station. MI observed in port side steering space, an emergency steering station with no rudder angle indicator. Vessel must install means of providing rudder angle indcator at that operating station.
46 CFR 182.610
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 14 June 2024
Resolution: Recieved email with photo confirmation of double clamping for bilge hoses. Additionally receieved receipt of rudder angle indcator system for e-steering position. Qualified MI reviewed photos and accepted.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 12 June 2024
Resolved
In systems and appliances where flexible hoses are permitted to be clamped, double hose clamping is required where practible. MI observed bilge dewatering system with flex hoses in both port and starboard steering flat without double clamping. Hoses must be double clamped.
46 CFR 182.410(d)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 14 June 2024
Resolution: Received photo evidence of double clamping of hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 May 2022
Resolved
The construction and arrangement vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull,protection against fire, means of escape in case of sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. On 03MAY2022, vessel reported loss of power/loss of propulsion.
Prior to passenger operations, vessel shall submit
repair plan for all impacted equipment, provide technician report attesting to operation of impacted machinery, and provide causal analysis report.
46 CFR 177.2100, 701c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2022
Resolution: A USCG Marine Inspector attended LITTLE LADY II (1194797) earlier today (13JUN2022) and cleared the remaining deficiency.
Operator sent a satisfactory causal analysis/technician report. MI documented reported under vessel’s profile. MI witnessed satisf
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 24 July 2020
Resolved
Fire Insulation is missing on overhead hatches in port and starboard enginge rooms; insulation is not fastened to overhead in port generator room.
46CFR177.410(c)(4)
Action required: 705 - Other - as specified
Due 27 July 2020
Resolved 27 July 2020
Resolution: Received email and pictures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 December 2019
Resolved
replace clutch circuit board and prove proper operation of the control system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2019
Resolution: Vessel made in kind replacement of the clutch relay circuit card and proved proper operation.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 December 2019
Resolved
fix the railing and fiberglass attachment point.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2019
Resolution: Vessel made proper repairs to the stbd fwd aluminum rail, all sat.