MAURY USCG vessel records Sign in
← All vessels

NOBLE DRILLER

NOBLE DRILLER is a 1976 mobile offshore drilling unit. The Coast Guard has recorded 9 inspections since 2007, most recently in August 2014, along with 14 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 2007 to 2014. Most recent: inspection, 7 August 2014.

Built
1976
Last inspected
7 August 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8752192 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
869110
Flag
LIBERIA
—
Maury page id
psix-869110

Inspections, by type

…with no type recorded3
…past their stated due date1
Years with a record 6 calendar years (2007–2014)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it13265 - Convention (Subpart B), Gross Ton
3980 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GOL RAVEN Offshore Supply Vessel · MISLE 924996 · 9 September 2011 · activity 4144200

Inspection history · 9

7 August 2014 COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4858878
1 March 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4809088
11 July 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4375849
9 July 2012 COC-MODU Annual · Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4373210
16 May 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4312895
9 September 2011 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4144200
3 March 2010 COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3702958
12 December 2008 COC-MODU Renew
Type not classified · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3367148
11 January 2007 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2854121

Deficiency record · 14

Lifesaving › Launching Appliances › Davit
Issued 8 August 2014 Resolved
Provide proper operation of lifeboat davit winch.
Due 14 August 2014
Resolved 13 August 2014
Resolution: Received email verificaton.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 8 August 2014 Resolved
Repair structrual integrity of hole in generator room.
Due 28 August 2014
Resolved 20 August 2014
Resolution: Received email verificaton.
Construction/Loadline › Structures › Manhole
Issued 8 August 2014 Resolved
P4 and S4 watertight hatch covers are missing indicators. Provide hatches with indicators.
Due 7 September 2014
Resolved 12 August 2014
Resolution: Received email verificaton.
Lifesaving › Lifeboat › Hull
Issued 7 August 2014 No resolution recorded
Repair rubber stops and associated damage on sides of all four lifeboats.
Due 8 August 2014 — due date passed with no resolution recorded
Lifesaving › Launching Appliances › Release Mechanism
Issued 9 July 2012 Resolved
Vsl could not supply proof of a release gear weight test for the rescue boat. Vsl must provide proof that this test was conducted by a competent third party representative
Action required: 705 - Other - as specified
Due 5 August 2012
Resolved 11 July 2012
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 9 July 2012 Resolved
APC fixed firefighting system activation handle has a broken glass tube that holds the handle in place. Have activation handle serviced and show that the glass rod is in place and unbroken.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 August 2012
Resolved 11 July 2012
Resolution: Received pictures from OIM showing newly installed glass tube.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 9 July 2012 Resolved
Battery Start system on E-Gen is inoperable. Replace/Repair batteries and connections to return the battery start to operational condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2012
Resolved 31 July 2012
Resolution: Received email stating that the battery installation is complete and working properly from [name withheld] (BS)
Construction/Loadline › Structures › Door
Issued 12 December 2008 Resolved
Prove proper operation of pump room watertight doors (107, 108) in all modes of operation including alarms to the satisfaction of classification society.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2008
Resolved 19 December 2008
Resolution: Received DNV report dated 17DEC08 attesting to satisfaction with watertight doors.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 12 December 2008 Resolved
Prior to drilling operations, prove proper operation of driller house pressure differential alarm system.
Action required: 705 - Other - as specified
Due 12 January 2009
Resolved 24 April 2009
Resolution: Via DNV report
Electrical › Electrical Distribution System (service) › Panelboard
Issued 12 December 2008 Resolved
Prior to drilling operations, prove proper operation of CMC control panel purge alarm system.
Action required: 705 - Other - as specified
Due 12 January 2009
Resolved 24 April 2009
Resolution: Via DNV report
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 12 December 2008 Resolved
Prior to drilling operations, fix broken door knob on forward side of driller house.
Action required: 705 - Other - as specified
Due 12 January 2009
Resolved 24 April 2009
Resolution: Via DNV Report
Fire Fighting › Ventilation Systems › Fans
Issued 12 December 2008 Resolved
Prior to drilling operations, prove proper operation of shaker room blowdown system including fusible links, automated dampers and fans.
Action required: 705 - Other - as specified
Due 12 January 2009
Resolved 24 April 2009
Resolution: Via DNV report
Fire Fighting › Structural - A Class Divisions › Doors
Issued 12 December 2008 Resolved
Prior to drilling operations, replace missing door closer between mud pit & mud pump room
Action required: 705 - Other - as specified
Due 12 January 2009
Resolved 24 April 2009
Resolution: Via DNV report
Communications › Alarms/Indicators › General Alarm
Issued 12 December 2008 Resolved
Repair damaged/disassembled GA alarm light in starboard pump room.
Action required: 705 - Other - as specified
Due 12 January 2009
Resolved 24 April 2009
Resolution: Via DNV report