Records from 2007 to 2014. Most recent: inspection, 7 August 2014.
Inspection history · 9
7 August 2014
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4858878
1 March 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4809088
11 July 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4375849
9 July 2012
COC-MODU Annual · Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4373210
16 May 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4312895
9 September 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4144200
3 March 2010
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3702958
12 December 2008
COC-MODU Renew
Type not classified · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3367148
11 January 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2854121
Lifesaving › Launching Appliances › Davit
Issued 8 August 2014
Resolved
Provide proper operation of lifeboat davit winch.
Due 14 August 2014
Resolved 13 August 2014
Resolution: Received email verificaton.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 8 August 2014
Resolved
Repair structrual integrity of hole in generator room.
Due 28 August 2014
Resolved 20 August 2014
Resolution: Received email verificaton.
Construction/Loadline › Structures › Manhole
Issued 8 August 2014
Resolved
P4 and S4 watertight hatch covers are missing indicators. Provide hatches with indicators.
Due 7 September 2014
Resolved 12 August 2014
Resolution: Received email verificaton.
Lifesaving › Lifeboat › Hull
Issued 7 August 2014
No resolution recorded
Repair rubber stops and associated damage on sides of all four lifeboats.
Due 8 August 2014 — due date passed with no resolution recorded
Lifesaving › Launching Appliances › Release Mechanism
Issued 9 July 2012
Resolved
Vsl could not supply proof of a release gear weight test for the rescue boat. Vsl must provide proof that this test was conducted by a competent third party representative
Action required: 705 - Other - as specified
Due 5 August 2012
Resolved 11 July 2012
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 9 July 2012
Resolved
APC fixed firefighting system activation handle has a broken glass tube that holds the handle in place. Have activation handle serviced and show that the glass rod is in place and unbroken.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 August 2012
Resolved 11 July 2012
Resolution: Received pictures from OIM showing newly installed glass tube.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 9 July 2012
Resolved
Battery Start system on E-Gen is inoperable. Replace/Repair batteries and connections to return the battery start to operational condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2012
Resolved 31 July 2012
Resolution: Received email stating that the battery installation is complete and working properly from [name withheld] (BS)
Construction/Loadline › Structures › Door
Issued 12 December 2008
Resolved
Prove proper operation of pump room watertight doors (107, 108) in all modes of operation including alarms to the satisfaction of classification society.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2008
Resolved 19 December 2008
Resolution: Received DNV report dated 17DEC08 attesting to satisfaction with watertight doors.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 12 December 2008
Resolved
Prior to drilling operations, prove proper operation of driller house pressure differential alarm system.
Action required: 705 - Other - as specified
Due 12 January 2009
Resolved 24 April 2009
Resolution: Via DNV report
Electrical › Electrical Distribution System (service) › Panelboard
Issued 12 December 2008
Resolved
Prior to drilling operations, prove proper operation of CMC control panel purge alarm system.
Action required: 705 - Other - as specified
Due 12 January 2009
Resolved 24 April 2009
Resolution: Via DNV report
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 12 December 2008
Resolved
Prior to drilling operations, fix broken door knob on forward side of driller house.
Action required: 705 - Other - as specified
Due 12 January 2009
Resolved 24 April 2009
Resolution: Via DNV Report
Fire Fighting › Ventilation Systems › Fans
Issued 12 December 2008
Resolved
Prior to drilling operations, prove proper operation of shaker room blowdown system including fusible links, automated dampers and fans.
Action required: 705 - Other - as specified
Due 12 January 2009
Resolved 24 April 2009
Resolution: Via DNV report
Fire Fighting › Structural - A Class Divisions › Doors
Issued 12 December 2008
Resolved
Prior to drilling operations, replace missing door closer between mud pit & mud pump room
Action required: 705 - Other - as specified
Due 12 January 2009
Resolved 24 April 2009
Resolution: Via DNV report
Communications › Alarms/Indicators › General Alarm
Issued 12 December 2008
Resolved
Repair damaged/disassembled GA alarm light in starboard pump room.
Action required: 705 - Other - as specified
Due 12 January 2009
Resolved 24 April 2009
Resolution: Via DNV report