Records from 2007 to 2026. Most recent: inspection, 22 April 2026.
Documentation record
Registered dimensions (L × B × D)154.7 ft × 34.0 ft × 12.1 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)154.7 ft × 34.0 ft × 12.1 ft
ITC tonnagegross 625 / net 235
BuilderGLADDING-HEARN SHIPBUILDING · SOMERSET, MA, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it235 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
625 - Convention (Subpart B), Gross Ton
96 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 32
22 April 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8354152
21 January 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8299286
24 April 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8118273
9 May 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7908837
13 March 2024
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7878627
13 March 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7881641
29 February 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7871807
2 May 2023
MTSA/ISPS Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7679474
8 April 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7664989
7 April 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7665055
31 May 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7464438
30 March 2022
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7421563
28 February 2022
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7405221
1 June 2021
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7212173
19 May 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7055186
10 April 2020
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6941240
7 May 2019
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6678504
21 December 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6601693
15 October 2018
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6561365
13 October 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6560418
13 October 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6565925
23 May 2018
COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6420699
16 March 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6392349
31 October 2017
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6298215
17 May 2017
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6147214
9 June 2016
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5901859
2 March 2016
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5829001
25 July 2012
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4389172
24 August 2011
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4124886
28 September 2010
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3860504
15 September 2008
Deficiency Check · In-Service Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3325168
9 October 2007
Deficiency Check · Initial Certification · Construction Oversight · Inclining Experiment
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3075997
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 9 May 2024
Resolved
A self propelled vessel must meet the applicable requirements for main and axillary steering apparatus in sub chapters F and J. Indication of the rudder angle must be provided both at the main steering station in the pilothouse and in the steering gear compartment. The axillary steering station did not have rudder angle indication. 46 CFR 119.600/ 46 CFR 58.25-25(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 17 May 2024
Resolution: MI received photographic evidence clearing the deficiency.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 March 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull... Operator notified this office that the vessel made contact with the Broadway Bridge, sustaining damage to the pilothouse. Vessel must receive inspection from CG MI, submit a repair plan for approval, and make satisfactory repairs IAW approved repair plan prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2024
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 2 May 2023
Resolved
Fire Protection Equipment: Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. If the storage cylinders are separate from the protected space, the instructions must also include a schematic diagram of the system and instructions detailing alternate methods of releasing the extinguishing agent should the local manual release or stop valve controls fail to operate.
Instructions for fire suppression system did not indicate correct operation for manual operation of CO2 system. Crew could not identify stop valves noted on instructions. Label stop valves, correct instructions and provide training to the crew on the new instructions.
Action required: 705 - Other - as specified
Due 16 May 2023
Resolved 9 May 2023
Resolution: Received picture of new labels and crew was provided training
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 May 2019
Resolved
Identified vital backup issue. 12 volt panel does not power vital equipment including VHF radios and bilge alarms when ship is placed in deadship electrical status. Vessel must be able to place ship in deadship status and prove full functionality of all vital systems served on 12 and 24 volt panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 15 May 2019
Resolution: Replace backup batteries
Construction/Loadline › Structures › Door
Issued 15 September 2008
Resolved
Install an indicator light at the operating station that will indicate when the watertight door located IWO frame 49 is open in accordance with 46 CFR 170.255(e).
Action required: 705 - Other - as specified
Due 1 October 2008
Resolved 20 October 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 August 2008
Resolved
Conduct Underway Drills
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 15 September 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 August 2008
Resolved
Conduct new to zone inspection
Due 15 September 2008
Resolved 15 September 2008
Personnel › Training › Fire Fighting Basic
Issued 29 August 2008
Resolved
Provide and post the station bill
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 15 September 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 29 August 2008
Resolved
Provide documentation the crew is enrolled in an approved drug and alcohol program
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 15 September 2008
Navigation › Piloting/Steering › Marine Charts
Issued 29 August 2008
Resolved
Provide appropriate logs, charts, navigation pubs, tide and current tables to the satisfaction of the local OCMI
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 15 September 2008
Stability › Incline Test › General
Issued 29 August 2008
Resolved
Provide and post the stability letter.
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 4 September 2008
Resolution: Stability letter posted.
Construction/Loadline › Penetrations › Pipe Flange
Issued 9 October 2007
Resolved
Complete attached 4 item worklist prior to departing Somerset, MA but no later than 3 Sep 08.
Complete installation of drains in the aft void and steering compartment.
Prove operation of the fire alarm horns and lights in the engine room, upper crew space, mens room, head passageway and the handicap head.
Install window safety devices.
Install deck plates in the machinery space.
Action required: 705 - Other - as specified
Due 3 September 2008