Records from 2009 to 2026. Most recent: inspection, 9 July 2026.
Documentation record
Registered dimensions (L × B × D)154.7 ft × 34.0 ft × 12.1 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)154.7 ft × 34.0 ft × 12.1 ft
ITC tonnagegross 625 / net 235
BuilderDUCLOS CORP · SOMERSET, MA, UNITED STATES · built 2009
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it625 - Convention (Subpart B), Gross Ton
96 - Regulatory (Subpart C or D), Gross Ton
235 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 32
9 July 2026
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8433910
2 February 2026
Annual Inspection · MSP Additional Oversight - Risk Assessment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8304760
19 March 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8095781
6 February 2025
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8075358
23 October 2024
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8022805
20 March 2024
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7872294
25 April 2023
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7609082
7 April 2023
Administrative Inspection · Damage Survey · Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7664837
7 April 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7665055
15 March 2023
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7650953
28 April 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7439733
3 March 2022
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7405977
21 April 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7179597
23 March 2021
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7160887
22 June 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6989120
4 October 2019
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6829864
3 October 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6829550
2 April 2019
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6654134
14 March 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6642306
21 December 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6601684
16 December 2018
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6598735
16 December 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6598794
28 March 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6384221
31 October 2017
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6298203
12 April 2017
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6123174
28 February 2017
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6096064
7 April 2016
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5848485
15 July 2015
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5184991
9 May 2012
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4306419
8 August 2011
Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4119573
22 April 2009
Deficiency Check · In-Service Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3464186
5 February 2009
Deadweight Survey · Deficiency Check · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3412736
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 March 2025
Resolved
"Each carbon dioxide extinguishing system installed or altered affter July 9, 2013 must have an approved odorizing unit to produce the scent of wintergreen." MI observed missing odorizing unit. Address the unit.
46 CFR 118.410
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 March 2025
Resolution: Vessel found to not require wintergreen.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 March 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Identified the vessel's engine unable to start after testing the CO2 system due to engine safety start interlock.
46 CFR 119.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2024
Resolution: Electrician cycled power to reset ECU and tested all terminals and circuits. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 March 2024
Resolved
Gauges to indicate engine revolutions per minute (RPM)... must be provided for all propulsion engines installed in the vessel. Identified RPM gauge in engine room for starboard engine to be inoperable. Outfit vessel with working gauge.
46 CFR 119.410
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2024
Resolution: Purchase invoice received and confirmed installation through objective photo evidence.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2024
Resolved
Equipment mounted on a hinged door of an enclosure must be constructed or shielded so that a person will not accidentally contact energized parts of the door mounted equipment when the door is open and the circuit energized. Identified distribution panel near concession stand to be open and exposing energized parts. Outfit vessel's exposed distribution panel with blanks.
46 CFR 120.330
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2024
Resolution: Objective photo evidence of installation received.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 March 2024
Resolved
Each vessel must be provided with bilge pumps in accordance with § 56.50–55 in sub chapter F of this chapter. Identified screw down valve in the forepeak to be hard to turn. Crew fixed the valve and exercised it multiple times in front of attending inspector.
46 CFR 119.520
Action required: 10 - Deficiency Rectified
Resolved 20 March 2024
Resolution: Screw down valve fixed and exercised all sat.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 March 2024
Resolved
Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. In addition, the penetration must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated. Identified penetration above the ladder in the engine room entrance from the main deck to be without fire stop. Vessel applied fire stop to the penetration.
46 CFR 116.415
Action required: 10 - Deficiency Rectified
Resolved 20 March 2024
Resolution: Fire stop used to plug cable penetration.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 20 March 2024
Resolved
Provisions shall be made by means of plugs, covers, etc, to prevent admission of air into the space protected. Identified port aft accordion style fire damper did not exercise when pulled. Crew investigated and found debris collected in accordion tracks. Cleaned out and exercised again. Attending MI witnessed actuating of fire damper after cleaning.
46 CFR 181.20-35 OLD T
Action required: 10 - Deficiency Rectified
Resolved 20 March 2024
Resolution: Accordian style damper track cleaned and exercised.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 25 April 2023
Resolved
Fire damper must be capable of manual operation from outside the space, foward stbd engine room damper does noit close tight. Must adjust to satifaction of CG MI.
46 CFR 116.610(g)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2023
Resolution: Adjusted and added heat solder link 165 degrees
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 25 April 2023
Resolved
Two means of escape muswt be provided. Escape from bridge to main deck fwd was blocked with trash can and anchor chain.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2023
Resolution: Crew moved bloackage.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 April 2023
Resolved
Proper means of storage must be provided for gas cylenders. CO2 bottle for soda system is not secured on main deck.
46 CFR 147
Action required: 705 - Other - as specified
Resolved 2 May 2023
Resolution: Installed bracket
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 25 April 2023
Resolved
Upper deck bar beer lines and lower deck snack bar is unsanitary with mold present. Any loose warmers or tables on wheels must be secured.
46 CFR 115.818
Action required: 705 - Other - as specified
Resolved 2 May 2023
Resolution: Beer lines removed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 April 2023
Resolved
2nd deck port fwd door leading to outside bridge wing is wasted at bottom so it is not weather tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2023
Resolution: Placed sheet metal over hole of door both sides.
Construction/Loadline › Penetrations › Valve Flange
Issued 28 February 2017
Resolved
1. Replace 01 through hull fitting valve prior to credit dry dock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 2 March 2017
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 8 August 2011
Resolved
Vessel rep called SPV Section Chief to inform that prop was lost at pier. Vessel to replace propeller and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2011
Resolution: Received fax from captain attesting to proper installation and operation of starboard propeller. Blueing indicated 80% contact. Operational sea trial full ahead and astern with no unusual performance.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 February 2009
Resolved
Prior to carrying passengers prove enrollment in an approved drug and alcohol program.
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 22 April 2009
Resolution: Proof of enrollment in drug program was verified.
Documentation › Logs/Records › Logbook (official)
Issued 5 February 2009
Resolved
Prior to carrying passengers provide the appropriate log books
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 22 April 2009
Resolution: All log books were provided.
Navigation › Piloting/Steering › Marine Charts
Issued 5 February 2009
Resolved
Prior to carrying passengers provide the appropriate charts, coast pilot, tide and current table and rules of the road to the satisfaction of the local OCMI.
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 22 April 2009
Resolution: Applicable charts and publications were provided.
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 February 2009
Resolved
Prior to carrying passengers properly conduct underway drills
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 22 April 2009
Resolution: Satisfactory fire drill, man overboard and security drills were completed as part of the new to zone inspection.
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 February 2009
Resolved
Prior to carrying passengers conduct new to zone inspection
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 22 April 2009
Resolution: New to zone inspection was conducted on April 22, 2009.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 5 February 2009
Resolved
Prior to carrying passengers provide a non tank vessel response plan
Action required: 705 - Other - as specified
Due 22 May 2009
Resolved 5 May 2009
Resolution: Received fax dated 5/5/2009 from Commandant CG-5431 giving temporary compliance for submission until final approval of the plan.
Communications › Public Address System › Broadcast Location
Issued 5 February 2009
Resolved
Prior to departing Somerset, MA prove proper operation of the PA system
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 15 April 2009