CIRCLE LINE QUEENS

CIRCLE LINE QUEENS is a 2009 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 2009, most recently in July 2026, along with 21 deficiencies and 3 casualty investigations between 2018 and 2023.

Records from 2009 to 2026. Most recent: inspection, 9 July 2026.

Built
2009
Last inspected
9 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE8154
941067
Flag
UNITED STATES
367402210
Maury page id
psix-941067

Inspections, by type

…with no type recorded3
Years with a record 15 calendar years (2009–2026)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)154.7 ft × 34.0 ft × 12.1 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)154.7 ft × 34.0 ft × 12.1 ft
ITC tonnagegross 625 / net 235
BuilderDUCLOS CORP · SOMERSET, MA, UNITED STATES · built 2009
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it625 - Convention (Subpart B), Gross Ton
96 - Regulatory (Subpart C or D), Gross Ton
235 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE8154MMSI 367402210 · active · compulsorily equipped · granted 20 February 2019, expires 1 April 2029
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CIRCLE LINE MANHATTAN Passenger (Inspected) · MISLE 869665 · 7 April 2023 · activity 7665055

Inspection history · 32

9 July 2026 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8433910
2 February 2026 Annual Inspection · MSP Additional Oversight - Risk Assessment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8304760
19 March 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8095781
6 February 2025 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8075358
23 October 2024 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8022805
20 March 2024 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7872294
25 April 2023 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7609082
7 April 2023 Administrative Inspection · Damage Survey · Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7664837
7 April 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7665055
15 March 2023 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7650953
28 April 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7439733
3 March 2022 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7405977
21 April 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7179597
23 March 2021 Administrative Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7160887
22 June 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6989120
4 October 2019 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6829864
3 October 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6829550
2 April 2019 MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6654134
14 March 2019 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6642306
21 December 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6601684
16 December 2018 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6598735
16 December 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6598794
28 March 2018 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6384221
31 October 2017 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6298203
12 April 2017 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6123174
28 February 2017 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6096064
7 April 2016 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5848485
15 July 2015 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5184991
9 May 2012 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4306419
8 August 2011 Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4119573
22 April 2009 Deficiency Check · In-Service Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3464186
5 February 2009 Deadweight Survey · Deficiency Check · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3412736

Deficiency record · 21

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 March 2025 Resolved
"Each carbon dioxide extinguishing system installed or altered affter July 9, 2013 must have an approved odorizing unit to produce the scent of wintergreen." MI observed missing odorizing unit. Address the unit. 46 CFR 118.410
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 March 2025
Resolution: Vessel found to not require wintergreen.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 March 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Identified the vessel's engine unable to start after testing the CO2 system due to engine safety start interlock. 46 CFR 119.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2024
Resolution: Electrician cycled power to reset ECU and tested all terminals and circuits. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 March 2024 Resolved
Gauges to indicate engine revolutions per minute (RPM)... must be provided for all propulsion engines installed in the vessel. Identified RPM gauge in engine room for starboard engine to be inoperable. Outfit vessel with working gauge. 46 CFR 119.410
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2024
Resolution: Purchase invoice received and confirmed installation through objective photo evidence.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2024 Resolved
Equipment mounted on a hinged door of an enclosure must be constructed or shielded so that a person will not accidentally contact energized parts of the door mounted equipment when the door is open and the circuit energized. Identified distribution panel near concession stand to be open and exposing energized parts. Outfit vessel's exposed distribution panel with blanks. 46 CFR 120.330
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2024
Resolution: Objective photo evidence of installation received.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 March 2024 Resolved
Each vessel must be provided with bilge pumps in accordance with § 56.50–55 in sub chapter F of this chapter. Identified screw down valve in the forepeak to be hard to turn. Crew fixed the valve and exercised it multiple times in front of attending inspector. 46 CFR 119.520
Action required: 10 - Deficiency Rectified
Resolved 20 March 2024
Resolution: Screw down valve fixed and exercised all sat.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 March 2024 Resolved
Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. In addition, the penetration must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated. Identified penetration above the ladder in the engine room entrance from the main deck to be without fire stop. Vessel applied fire stop to the penetration. 46 CFR 116.415
Action required: 10 - Deficiency Rectified
Resolved 20 March 2024
Resolution: Fire stop used to plug cable penetration.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 20 March 2024 Resolved
Provisions shall be made by means of plugs, covers, etc, to prevent admission of air into the space protected. Identified port aft accordion style fire damper did not exercise when pulled. Crew investigated and found debris collected in accordion tracks. Cleaned out and exercised again. Attending MI witnessed actuating of fire damper after cleaning. 46 CFR 181.20-35 OLD T
Action required: 10 - Deficiency Rectified
Resolved 20 March 2024
Resolution: Accordian style damper track cleaned and exercised.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 25 April 2023 Resolved
Fire damper must be capable of manual operation from outside the space, foward stbd engine room damper does noit close tight. Must adjust to satifaction of CG MI. 46 CFR 116.610(g)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2023
Resolution: Adjusted and added heat solder link 165 degrees
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 25 April 2023 Resolved
Two means of escape muswt be provided. Escape from bridge to main deck fwd was blocked with trash can and anchor chain.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2023
Resolution: Crew moved bloackage.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 April 2023 Resolved
Proper means of storage must be provided for gas cylenders. CO2 bottle for soda system is not secured on main deck. 46 CFR 147
Action required: 705 - Other - as specified
Resolved 2 May 2023
Resolution: Installed bracket
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 25 April 2023 Resolved
Upper deck bar beer lines and lower deck snack bar is unsanitary with mold present. Any loose warmers or tables on wheels must be secured. 46 CFR 115.818
Action required: 705 - Other - as specified
Resolved 2 May 2023
Resolution: Beer lines removed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 April 2023 Resolved
2nd deck port fwd door leading to outside bridge wing is wasted at bottom so it is not weather tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2023
Resolution: Placed sheet metal over hole of door both sides.
Construction/Loadline › Penetrations › Valve Flange
Issued 28 February 2017 Resolved
1. Replace 01 through hull fitting valve prior to credit dry dock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 2 March 2017
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 8 August 2011 Resolved
Vessel rep called SPV Section Chief to inform that prop was lost at pier. Vessel to replace propeller and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2011
Resolution: Received fax from captain attesting to proper installation and operation of starboard propeller. Blueing indicated 80% contact. Operational sea trial full ahead and astern with no unusual performance.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 February 2009 Resolved
Prior to carrying passengers prove enrollment in an approved drug and alcohol program.
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 22 April 2009
Resolution: Proof of enrollment in drug program was verified.
Documentation › Logs/Records › Logbook (official)
Issued 5 February 2009 Resolved
Prior to carrying passengers provide the appropriate log books
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 22 April 2009
Resolution: All log books were provided.
Navigation › Piloting/Steering › Marine Charts
Issued 5 February 2009 Resolved
Prior to carrying passengers provide the appropriate charts, coast pilot, tide and current table and rules of the road to the satisfaction of the local OCMI.
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 22 April 2009
Resolution: Applicable charts and publications were provided.
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 February 2009 Resolved
Prior to carrying passengers properly conduct underway drills
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 22 April 2009
Resolution: Satisfactory fire drill, man overboard and security drills were completed as part of the new to zone inspection.
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 February 2009 Resolved
Prior to carrying passengers conduct new to zone inspection
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 22 April 2009
Resolution: New to zone inspection was conducted on April 22, 2009.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 5 February 2009 Resolved
Prior to carrying passengers provide a non tank vessel response plan
Action required: 705 - Other - as specified
Due 22 May 2009
Resolved 5 May 2009
Resolution: Received fax dated 5/5/2009 from Commandant CG-5431 giving temporary compliance for submission until final approval of the plan.
Communications › Public Address System › Broadcast Location
Issued 5 February 2009 Resolved
Prior to departing Somerset, MA prove proper operation of the PA system
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 15 April 2009

Casualty record · 3

16 December 2018Routine · role: Involved in a Marine Casualty · at BROADWAY BRIDGE · activity 6598794
3 October 2019Routine · role: Involved in a Marine Casualty · activity 6829550
7 April 2023Routine · role: Involved in a Marine Casualty · activity 7665055
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.