Records from 2007 to 2026. Most recent: inspection, 11 July 2026.
Inspection history · 73
11 July 2026
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8437045
5 November 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8264390
12 June 2025
Deficiency Check · Annual Inspection · ACP Annual Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8141877
4 October 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8014312
5 September 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7998021
7 May 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7908329
5 April 2024
COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7890097
7 March 2023
Annual Inspection · ACP Annual Oversight · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7654732
8 November 2022
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7591420
28 March 2022
Drydock Exam · ACP Handover Survey · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7422327
4 February 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7390936
25 October 2021
Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7337012
2 June 2021
Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7214785
4 March 2021
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7151123
19 February 2021
Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7142706
18 February 2021
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7142919
18 June 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6980209
16 January 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6624282
10 December 2018
MTSA/ISPS Verification · Drydock Exam · Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6633095
21 May 2018
MTSA/ISPS Verification · MARPOL Annex I Examination · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6416984
11 September 2017
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6264170
11 September 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6271171
27 April 2017
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6129134
22 February 2017
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6134235
14 November 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6040807
14 November 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6041067
9 October 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6020435
26 May 2016
Annual Inspection · Deficiency Check · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5895565
22 October 2015
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5748545
8 August 2015
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5219113
7 May 2015
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5118575
22 October 2014
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5011568
22 October 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5012766
18 September 2014
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4990193
6 June 2014
Damage Survey · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4881303
28 February 2014
MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4809393
12 February 2014
Examination of Repairs · In-Service Inspection · Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4798693
9 February 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4797328
22 January 2014
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4789895
31 July 2013
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4671312
23 July 2013
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4662129
23 July 2013
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4662267
18 July 2013
Damage Survey · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4658034
18 July 2013
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4662227
13 March 2013
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4545686
18 February 2013
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4535421
7 September 2012
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4438559
27 August 2012
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4423887
14 June 2012
Plan Review (Other than "T")
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4344435
23 May 2012
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4319179
7 March 2012
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4258455
15 December 2011
Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4209076
14 December 2011
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4208547
14 December 2011
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4212252
4 December 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4201741
4 December 2011
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4204893
21 November 2011
Hull Examination · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4186652
10 November 2011
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4193849
27 September 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4167139
17 March 2011
Periodic Inspection · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3969035
12 March 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3963785
21 December 2010
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3914321
9 October 2010
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 3866779
9 October 2010
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3869133
28 July 2010
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3808649
28 July 2010
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3808825
28 July 2010
Damage Survey · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3810246
7 April 2010
Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3711631
22 March 2010
Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3700347
29 October 2009
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3626538
14 August 2009
Excursion Permit
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3609155
6 March 2009
MARPOL Annex I Examination · Initial Certification · Security Plan Review - VSP · Ballast Water Examination · MTSA/ISPS Verification · Inclining Experiment · Plan Review (Other than "T") · DAPI Audit · Construction Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3428931
18 December 2007
Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3117657
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 November 2025
Resolved
Auxiliary machinery vital to the main propulsion system must be provided in duplicate unless the system served is provided in independent duplicate, or otherwise provides continued or restored propulsion capability in the event of a failure or malfunction of any single auxiliary component. Vessel reported one of two auxiliary diesel generators inoperable.
Provide causal analysis and make proper repairs prior to ATB cargo operations.
One tug escort required while moving inbound and around San Francisco Bay OCMI/COTP Zone.
46 CFR 58.01-35
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2025
Resolution: RO (ABS) attended vessel and determined that starboard generator starter was defective and replaced with spare as appropriate. Starts and performance capabilities for both generators were tested and verified to be in good order.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 June 2025
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that: any non-conformity is reported, with its possible cause, if known; appropriate corrective action is taken; and records of these activities are maintained. Deficiencies 2, 3, 4, 5, and 6 were identified by attending inspectors and associated internal non-conformities were not available. Company shall conduct an internal vessel audit focused on these findings within 3 months. 74 SOLAS (20) IX/3.1 ISM CODE 10.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2025
Resolved 22 September 2025
Resolution: Audit provided and training completed.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 12 June 2025
Resolved
Every person designated to take charge of medical care onboard vessels subject to the STCW Convention must hold an MMC endorsed as Person in Charge of Medical Care. Vessel sailed without PIC medical care designated or qualified crew member during the previous voyage. 46CFR15.404(i)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 17 June 2025
Resolution: Verified designation on newly signed on Captain.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 June 2025
Resolved
The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and life raft embarkation deck.02 emergency escape hatches (01 engine room and 01 forward stores) found not easily operable to allow a swift means of escape. Forward stores hatch noted as having an outstanding work order for repair from July of 2024. 74SOLAS(20)II-2/13
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 16 June 2025
Resolution: Accepted by RO.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 12 June 2025
Resolved
Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. Vessel found utilizing Periodic Safety Test Procedures which had been modified multiple times after approval without resubmittal. Records were not available to indicate procedures had been completed during the previous calendar year. 74SOLAS(20)II-1/46.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 9 September 2025
Resolution: Witnessed satisfactory testing of revised PSTPs.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 12 June 2025
Resolved
It shall be the duty of the master or other person in charge of the vessel to see that all of the provisions of the certificate of inspection are strictly adhered to. Vessel found utilizing outdated conditional occupancy policy. Vessel records indicate canceled CG-CVC Policy 16-04 in use in lieu of requirements found in NVIC02-81 CH2. 46CFR97.50-1(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 12 July 2025
Resolution: Accepted documentation satisfying 835.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 June 2025
Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. Two dead end live green wires under port bridge console and approximately 4 non-energized wires under starboard bridge console were identified. 74SOLAS(20)II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 16 June 2025
Resolution: Accepted/cleared by RO.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 12 June 2025
Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out in a manner having due regard to ensuring reliability of such appliances. Line throwing rockets all found expired. 74SOLAS(20)III/20.3.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 16 June 2025
Resolution: Accepted/cleared by RO.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 June 2025
Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. Panel boards throughout vessel found with multiple circuit directories missing information or breakers not matching installed breakers.74SOLAS(20) II-1/45.6.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 16 June 2025
Resolution: Accepted/cleared by RO.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 12 June 2025
Resolved
In order to achieve the fire safety objectives set out in paragraph 1, the following functional requirements are embodied in the regulations of this chapter as appropriate: ready availability of fire-extinguishing appliances. Fire and safety lockers found disorganized hindering ready access to critical safety equipment. 74 SOLAS (20) II-2/2.1.7
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 16 June 2025
Resolution: Accepted/cleared by RO.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 12 June 2025
Resolved
All general alarm bells shall be identified by red lettering at least ½ inch high: GENERAL ALARM – WHEN BELL RINGS TO GO YOUR STATION. Required signage in AC Flat found painted over. 46 CFR97.37-7
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 June 2025
Resolution: Crew installed new signage.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 June 2025
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: the ignitability of combustible materials shall be restricted. Exhaust fan for purifier room found coated in oily buildup. 74 SOLAS (20) II-2/4.1.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 16 June 2025
Resolution: Accepted/cleared by RO.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 June 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Lagging at emergency fuel oil shutoff air supply line in AC flat to upper purifier requires repair. 74SOLAS(20)I-11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 16 June 2025
Resolution: Accepted/cleared by RO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 June 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Leak found on fuel oil vent containment drain line in the ER overhead. Patch found on jacket water holding tank vent line.?Leak found on the salt water inlet flange for the foam system.?74SOLAS(20)I-11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 16 June 2025
Resolution: Accepted/cleared by RO.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 12 June 2025
Resolved
(a) On a merchant vessel of the United States the construction of which began after March 4th, 1915..(5) each crew berthing area shall be equipped with information regarding-(A) vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, and drug and alcohol usage; and (B) procedures and resources to report crimes, including sexual assault and sexual harassment, including information-(i) on the telephone number, website address, and email address for reporting allegations of sexual assault and sexual harassment to the Coast Guard;(ii) on vessel owner or company procedures to report violations of company policy and access resources; (iii) on resources provided by outside organizations such as sexual assault hotlines and counseling;(iv) on the retention period for surveillance video recording after an incident of sexual harassment or sexual assault is reported; and (v) additional items specified in regulations issued by, and at the discretion of, the Secretary of the department in which the Coast Guard is operating. (d) In each washing space in a visible location there shall be information regarding procedures and resources to report crimes upon the vessel, including sexual assault and sexual harassment, and vessel owner or company policies prohibiting sexual assault and and sexual harassment, retaliation, and drug and alcohol usage. Vessel missing required signage in crew berthing areas. 46 U.S. Code 11011
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 17 June 2025
Resolution: Accepted updated sheet with required SASH info posted in berthing.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 12 June 2025
Resolved
(a) In General.-The owner of a vessel subject to inspection under section 3301 shall-(1) ensure that such vessel is equipped with a vessel master key control system, manual or electronic, which provides controlled access to all copies of the vessel's master key of which access shall only be available to the individuals described in paragraph (2); (2) establish a list of all crew, identified by position, allowed to access and use the master key and maintain such list upon the vessel, within owner records and included in the vessel safety management system; (3) record in a log book information on all access and use of the vessel's master key, including- (A) dates and times of access; (B) the room or location accessed; and (C) the name and rank of the crew member that used the master key; and (4) make the list under paragraph (2) and the log book under paragraph (3) available upon request to any agent of the Federal Bureau of Investigation, any member of the Coast Guard, and any law enforcement officer performing official duties in the course and scope of an investigation. Vessel found not complying with shipboard Master [name withheld] document, sections 5.2 and 5.3. 46 U.S. Code 3106
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 12 July 2025
Resolution: Accepted documentation satisfying 835.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 March 2019
Resolved
Provide vessel with proper flammable liquid storage (paint is stored in bosun locker)
Action required: 705 - Other - as specified
Resolved 21 May 2019
Resolution: Paint stored in proper flammable liquid lockers located on 02 deck, starboard side.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Emergency shutdown
Issued 21 May 2018
Resolved
Stbd ship service generator taken off line due to failure metal shavings found in oil.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 May 2018
Resolved 21 May 2018
Resolution: Stbd ship service generator has been replaced in kind.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 21 May 2018
Resolved
Non metallic expansion joints on the port MDE and the stbd ssdg found detreated and cracked.
Action required: 10 - Deficiency Rectified
Due 21 May 2018
Resolved 21 May 2018
Resolution: Non metallic expansion joints on the port MDE and the stbd ssdg have been renewed.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 21 May 2018
Resolved
Class A doors 01 deck of stair tower would not close as required.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 May 2018
Resolved 21 May 2018
Resolution: Crew made adjustments to door closing meconium
Operations/Management › Pollution › Control of Garbage
Issued 21 May 2018
Resolved
vessel has been discharging food waste into the sea in the Gulf of Mexico no grinder installed.The Gulf of Mexico is a no discharge area unless food waste is processed threw a grinder.
Action required: 10 - Deficiency Rectified
Due 21 May 2018
Resolved 21 May 2018
Resolution: Vessel was instructed to hold all food waste on board until arrangements are made to send waste ashore or install food grinder before discharge at sea.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 21 May 2018
Resolved
Safety management system contains outdated garbage management plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 31 May 2019
Resolution: Sighted updated plan.
Engineering › Diesel Engine (propulsion-electric) › Governor
Issued 11 September 2017
Resolved
Vessel is to remain at achorage 9 and complete repairs on reported port engine governor control. Provide technician report. 46CFR91.45-5
Action required: 705 - Other - as specified
Resolved 12 September 2017
Resolution: Received technician report that a screw was loose on the governor drive. Issue addressed, full load test completed with satisfactory results.
Stability › Watertight Integrity › General
Issued 27 April 2017
Resolved
Ensure proper operation & fitting for watertight door as i.d. on vessel drawings
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 5 May 2017
Resolution: Def cleared
Engineering › Pressure Vessel › Relief Valve
Issued 27 April 2017
Resolved
Replace relief valve as indicated to ensure valve does not reliefe above MAWP/250 as i.d. on ship service air.
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 5 May 2017
Resolution: Def cleared
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 14 November 2016
Resolved
Repair Port Engine prior to vessel movement. If vessel needs to move, vessel is required to contact local Marine Inspections office. All items to be completed to the satisfaction of the cognizant OCMI
Due 14 November 2016
Resolved 16 November 2016
Resolution: The vessel had effected repairs to the port MDE cylinder #6 fuel pump follower as per manufacturer representative recommendations. The main engine was then tested both ahead, astern and clutched out at maximum operational rpm. All appeared satisfactory.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 27 May 2016
Resolved
Rudder angle indicators are not consistent between the bridge and engine room. Align indicators to match.
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 27 May 2016
Resolution: Indicators were adjusted to align.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 27 May 2016
Resolved
Include reverse power relay testing procedure in Periodic Safety Test Procedures IAW; 46CFR62.01-5 (b)(1), Applicability, 46CFR62.20-1(a)(7), Plans for approval and 46CFR61.40-10(a), Test procedure details .
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 31 May 2019
Resolution: Sighted updateed reauirement and operational test of equipment IAW PSTP.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 7 May 2015
Resolved
46 CFR 58.25-25(b): Rudder angle indictor at local control station in engine room reading off by 10 degrees in right rudder direction. Properly calibrate rudder indicators.
Due 30 June 2015
Resolved 8 May 2015
Resolution: Received emailed tech report indicating proper repair of the rudder angle indicator.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 7 May 2015
Resolved
46 CFR 111.12-11(f): Port generator reverse power relay not functioning. Crew to not operate in parallel except to switch generators until repaired. Repair port generator reverse power relay.
Due 7 June 2015
Resolved 8 May 2015
Resolution: 3rd party vendor, Elite Electrical, on board and effect repairs to the port generator reverse power relay. Function tests conducted with no further incident.
Electrical › Electric Supply System (service) › Cable
Issued 7 May 2015
Resolved
46 CFR 111.60-17: Dead end electrical cable coiled above engine room alarm and monitoring panels not properly terminated. Properly terminate dead end wiring.
Due 7 June 2015
Resolved 8 May 2015
Resolution: Dead end electrical cables properly secured with wire nuts and terminated in J-box. See pictures attached.
Electrical › Electric Generation Source (service) › Panelboard
Issued 7 May 2015
Resolved
46 CFR 111.30-25(d): Main switchboard equipped with synchroscope but no synchronizing lamp. Provide synchronizing lamp.
Due 11 November 2015
Resolved 22 October 2015
Resolution: Operator installed lamps.
Construction/Loadline › Hull › Bottom Plating
Issued 12 February 2014
Resolved
A 6'' fracture has developed in the starboard #2 fuel oil day tank. The bottom of the tank forms the bottom hull plating. The fracture is located on the bottom plating above the starboard shaft strut where the outboard bulkhead joins the bottom plating. The fracture has completely breeched the hull.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2014
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 12 February 2014
Resolved
The starboard propeller shaft seal has spun inside its collar rendering the starboard shaft out of commission.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2014
Engineering › Steering Gear System › Pump
Issued 23 July 2013
Resolved
On 23JULY2013 vessel reported that the #1 steering gear pump was not working. Vessel switched to #2 pump and sailed into Port Angeles for repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2013
Resolution: Problem was found in the port side rudder. Potentiometer and associated wiring was renewed and tested. All sat.
Engineering › Steering Gear System › Follow-up Assembly
Issued 18 July 2013
Resolved
Upon completion of repairs to the steering gear follow-up controller and prior to getting underway, conduct steering gear test in the presence of the attending Coast Guard Marine Inspector. Test to be conducted in accordance with 33 CFR § 164.25
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2013
Resolved 19 July 2013
Resolution: Attended vessel after tech reps made repairs. Conducted satisfactory steering gear tests in all modes.
Engineering › Lubricating Oil Service System › Piping
Issued 15 December 2011
Resolved
Vessel may not operate until proper operation of the main engine and related systems are witnessed by the attending Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Camshaft
Issued 4 December 2011
Resolved
Renew/repair port engine camshaft speed sensor with satisfactory test.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2011
Resolution: Speed sensor renewed, tested sat. ABS class report verifacation #ABSID 09176691
Engineering › Steering Gear System › Valve, Control
Issued 7 April 2010
Resolved
Make effective repairs to to vessel's steering system.
Perform post-repair operation of the steering system in the presence of the attending Marine Inspector.
Conduct U/W operational test of the steering system under normal U/W loads on the rudders.
Upon successful completion of test notify attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2010
Lifesaving › Rescue Boat › Propulsion Engine
Issued 22 March 2010
Resolved
Prove that rescue boat engine is SOLAS compliant prior to sailing on an international voyage.
Due 31 March 2010
Resolved 22 March 2010
Resolution: Received email containing scan of engine paperwork.