MAURY USCG vessel records
← All vessels

650-6

Built
2009
Last inspected
8 January 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 8 January 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 18 calendar years (2007–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9369368
877598
Flag
UNITED STATES
Maury page id
psix-877598

Documentation record

Registered dimensions (L × B × D)559.8 ft × 74.0 ft × 40.1 ft
Registered tonnagegross 11,147 / net 11,147
ITC dimensions (L × B × D)559.8 ft × 74.0 ft × 40.1 ft
ITC tonnagegross 13,462 / net 8,791
BuilderVT HALTER MARINE INC · PASCAGOULA, MS, UNITED STATES · built 2009
Hull materialSteel
PropulsionNone
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 17 June 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13462 - Convention (Subpart B), Gross Ton
11147 - Regulatory (Subpart C or D), Gross Ton
8791 - Convention (Subpart B), Net Ton
27023 - Dead Weight, Ton
11147 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 33 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

COMMITMENT Towing Vessel · MISLE 870714 · 8 August 2015 · activity 5219113COMMITMENT Towing Vessel · MISLE 870714 · 23 July 2013 · activity 4662267COMMITMENT Towing Vessel · MISLE 870714 · 4 December 2011 · activity 4201741

Inspection history · 33

8 January 2026 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8292464
12 June 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8158729
4 October 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8014349
6 March 2024 COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7875060
12 September 2023 Bulk Liquid Transfer Monitor
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7790480
7 March 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7650228
8 April 2022 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7416133
14 October 2021 Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7327837
2 June 2021 Periodic Inspection · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7214099
18 June 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6980114
10 December 2018 COI Inspection · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6606613
21 May 2018 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6422761
27 April 2017 DAPI Audit · Periodic Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6129117
22 February 2017 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6134238
26 September 2016 Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6011343
27 May 2016 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5900592
22 October 2015 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5748549
8 August 2015 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5219113
7 May 2015 MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5118343
22 November 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5028396
14 September 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4982757
22 January 2014 Drydock Exam · MTSA Verification · COI Inspection · Internal Structural Exam · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4789899
23 July 2013 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4662267
19 October 2012 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4467628
17 August 2012 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4414051
23 May 2012 MARPOL Annex I Examination · Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4320536
9 May 2012 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4312545
7 March 2012 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4258818
4 December 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4201741
17 November 2011 Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4190664
22 March 2010 MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3700351
16 March 2009 Ballast Water Examination · Plan Review (Other than "T") · Construction Oversight · MARPOL Annex II Examination · Deadweight Survey · MARPOL Annex I Examination · MTSA/ISPS Verification · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3434426
18 December 2007 Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3117660

Deficiency record · 13

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 June 2025 Resolved
All installations must be of marine type engines suitable for the intended service, designed and constructed in conformance with the requirements of this subchapter. Identified fuel leaks coming from the fuel rail on the #1 and #2 cylinders.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 July 2025
Resolution: Received ABS Class report attesting to repairs made to generator. Attending surveyor tested at full load with no leaks observed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 June 2025 Resolved
All installations must be of marine type engines suitable for the intended service, designed and constructed in conformance with the requirements of this subchapter. Fuel line on hotel generator was dry rotted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 July 2025
Resolution: Received ABS Class report attestsing to replacement of fuel line. Attending surveyor tested at full load with no leaks observed.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 21 May 2018 Resolved
Non-metallic expansion joints showed significant signs of fatigue and deterioration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2018
Resolved 21 May 2018
Resolution: All non-metallic expansion joints replaced prior to CG team departing.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 5 May 2017 Resolved
Amend barge fire control plans to remove foam system storage tanks, and submit new plan to OCMI for review.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 17 May 2017
Resolution: See Narrative.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 27 April 2017 Resolved
Provide replacement/ equivilant for fixed foam system on deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2017
Resolution: Equivalency properly installed/operational, see narrative.
Deck/Cargo › Cargo Heating › General
Issued 27 April 2017 Resolved
Repair motor controller for thermal fluid heater, restricted from thermal fluid heater operation until motor repaired.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 5 May 2017
Resolution: See Narrative.
Communications › Audible Communications › Horn/Whistle
Issued 27 April 2017 Resolved
Secure cargo high level alarm [loose connection] located on port machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 5 May 2017
Resolution: See Narrative.
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 27 April 2017 Resolved
Provide satisfactory testing of all pressure vessels, internals, and relief valves.
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 28 April 2017
Resolution: See Narrative.
Construction/Loadline › Structures › End Bulkhead
Issued 26 September 2016 Resolved
Identify and provide authorized repairs for source of product weepage from cargo tank into #3P Ballast tank. Pin hole leak located in #3P Ballast tank, near aft bulkhead, on deep well pump reservoir, overhead weld seam.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2016
Resolution: Identified pin hole leak in cargo tank #3. Back gouged, and rewelded full penetration seam. Mag particle passed NDT, and air pressure test of tank at 1 PSI passed. ABS witness, submitted tech report.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 7 May 2015 Resolved
Vessel shall provide line diagrams of vessel's transfer piping and vapor collection system piping to include in the transfer procedures IAW 33CFR155.750.
Condition: Invalid
Due 7 June 2015
Resolved 8 May 2015
Resolution: Port Engineer provided copy of line diagram of vessel''s transfer piping arrangements.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 7 May 2015 Resolved
Vessel shall install a synchronizing lamp for paralleling generators IAW 46 CFR 111.30-25(d)(3).
Condition: Invalid
Due 11 November 2015
Resolved 22 October 2015
Resolution: Company provided syncronizing lamps.
Electrical › Electric Supply System (service) › Reverse Current Protection
Issued 7 May 2015 Resolved
Vessel shall prove operation of the reverse power relay for paralleling generators IAW 46 CFR 111.12-11(f).
Condition: Invalid
Due 7 June 2015
Resolved 8 May 2015
Resolution: Chief Engineer provided evidence that satisfactory test of reverse power relay was conducted.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 7 May 2015 Resolved
Vessel removed relief valves on discharge side of cargo pumps. Provide relief valves or proof that cargo pumps are not capable of providing pressure above the maximum allowable working pressure of the system IAW 46 CFR 56.07-10(b).
Condition: Invalid
Due 7 June 2015
Resolved 8 May 2015
Resolution: Vessel provided approval letter from Marine Safety Center approving the removal of the cargo pump relief valves. Letter E1-1203488.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.