Records from 2007 to 2026. Most recent: inspection, 11 February 2026.
Inspection history · 49
11 February 2026
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8309439
6 March 2025
Annual Inspection · DAPI Audit · MTSA/ISPS Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8089442
6 November 2023
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7820973
7 September 2023
MARPOL Annex VI Survey · MARPOL Annex I Examination · Drydock Exam · Administrative Inspection · COI Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7787152
2 February 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7630978
20 January 2023
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7619277
15 December 2022
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7609406
9 May 2022
In-Service Inspection · Plan Review (Other than "T") · Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7446687
22 February 2022
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7399665
19 October 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7335130
23 September 2021
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7318818
2 February 2021
Periodic Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · MTSA/ISPS Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7134438
5 August 2020
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7024515
2 April 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6934488
24 October 2019
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6840867
9 October 2019
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6831710
19 September 2019
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6815578
29 July 2019
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6766535
20 May 2019
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6698062
22 October 2018
MARPOL Annex IV Survey · MARPOL Annex II Examination · Internal Structural Exam · MARPOL Annex I Examination · Drydock Exam · Examination of Repairs · MTSA/ISPS Verification · MARPOL Annex VI Survey · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6565566
27 September 2018
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6549863
23 February 2018
MTSA/ISPS Verification · MARPOL Annex I Examination · MARPOL Annex VI Survey · Annual Inspection · SIP Inspection/Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6357980
18 January 2018
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6339619
2 January 2018
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6331203
22 November 2017
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6311507
13 June 2017
In-Service Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6174706
26 April 2017
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6132915
22 February 2017
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6095322
9 January 2017
Annual Inspection · MARPOL Annex I Examination · Deficiency Check · SIP Inspection/Audit · MTSA/ISPS Verification · MARPOL Annex VI Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6065637
10 November 2016
Examination of Repairs · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6038879
17 October 2016
Drydock Extension
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6024019
20 June 2016
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5917627
27 December 2015
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5798142
26 October 2015
SIP Initial Entry · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5751108
21 October 2015
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5748105
28 October 2014
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5013690
25 August 2014
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4967767
5 June 2014
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4880977
4 June 2014
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4880970
27 May 2014
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4871078
28 March 2014
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4824942
3 January 2012
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4232802
21 July 2011
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4085844
15 September 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3874208
4 March 2010
Annual Inspection · SIP Inspection/Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3688686
8 July 2009
In-Service Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3534672
9 April 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3493095
17 January 2008
Construction Oversight · Initial Certification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3194562
17 October 2007
Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3077887
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2023
Resolved
The main steering gear must be—Of adequate strength for and capable of steering the vessel at maximum ahead service speed, which must be demonstrated to the satisfaction of the cognizant Officer in Charge, Marine Inspection. Vessel was unable to demonstrate adequate steering. 46 CFR 58.25-10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2023
Resolution: Vessel repaired hoses and rudder angle indicators. in the EOS the port indicator still sticks during operation and CE will put request though thier maintenace system(NS5) to replace it.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 23 October 2023
Resolved
A personnel alarm must be provided and must annunciate on the bridge if not routinely acknowledged at the ECC or in the machinery spaces. Screen needed to use alarm is inoperative and others are locked out. Conduct risk assessment per SMS.
46 CFR 62.50-20
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2023
Resolution: Vessel provided approved risk assessment. Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 October 2023
Resolved
An approved automatic fire detection and alarm system must be provided to monitor all machinery spaces. The system must activate all alarms at the ECC, the navigating bridge, and throughout the machinery spaces and engineers' accommodations. The ECC and bridge alarms must visually indicate which machinery space is on fire, as applicable. Multiple fire detection heads did not operate when tested. 46 CFR 62.50-20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2023
Resolved 6 November 2023
Resolution: Cleared tested
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2023
Resolved
The status of automatically or remotely controlled vital auxiliaries, power sources, switches, and valves must be visually indicated in the machinery spaces or the cognizant remote control location, as applicable. Main Switchboard breaker indicator shows shore power and generator closed at same time, while shore power was open. 46 CFR 62.25-20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 10 January 2024
Resolution: Replaced Breaker
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 October 2023
Resolved
General arrangement plans showing for each deck the various fire sections enclosed by fire resisting bulkheads. The A-60 boundary in the Fidley space did not meet the structural fire protection requirements according to the approved Fire Control Plan. 46 CFR 91.55-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 24 October 2023
Resolution: Structural fire protection was installed correctly. Deficiency rectifed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 October 2023
Resolved
All required fire pump remote control locations must include the controls necessary to charge the firemain and— (1) A firemain pressure indicator; Fire pressure main gauge does not meet the requirements of PSTP task 4.6.4 46 CFR 62.35-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 6 November 2023
Resolution: Cleared
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2023
Resolved
Equipment for interior locations not requiring exceptional degrees of protection must be manufactured to at least NEMA 250 Type 1 with drip shield or IEC 60529:2013 IP 11. Drip shields missing from 3 e-generator battery chargers. 46 CFR 111.01-9
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 24 October 2023
Resolution: Drip shields placed over battery chargers.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 23 October 2023
Resolved
Each cargo vessel must carry an immersion suit approved under approval series 160.171 of an appropriate size for each person on board. Missing 1 immersion suit. 46 CFR 199.273
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 24 October 2023
Resolution: Vessel has all required immersion suits on board. Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 23 October 2023
Resolved
A minimum of two two-way portable radiotelephone apparatus for each fire party for fire-fighter’s communication shall be carried on board and be of an explosion-proof type or intrinsically safe. Fire-fighter’s radios were not of an explosion-proof type or intrinsically safe. 74 SOLAS (2020 Cons) II-2/10.10.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 24 October 2023
Resolution: Vessel demonstrated that battery packs are intrinsically safe from mfg cetrifcated even though not marked by UL.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 October 2023
Resolved
Certain material is incorporated by reference in this part with the approval of the Director of the Federal Register under 5 U.S.C. 552(a) and 1 CFR part 51. (b)(7) Resolution A.760(18), Symbols Related to Life-saving Appliances and Arrangements, adopted November 4, 1993, IBR approved for §§ 199.70; 199.90. 46 CFR 199.05
Missing required placards
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 24 October 2023
Resolution: Missing placards were placed in service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2023
Resolved
Test procedure documents must be in a step-by-step or checkoff list format. Each test instruction must specify equipment status, apparatus necessary to perform the tests, safety precautions, safety control and alarm setpoints, the procedure to be followed, and the expected test result. Automation test procedures has multiple errors such as ME set points, location and number of smoke detectors, RPM thruster J/W pressure, alarms are to be conducted, and others. Test procedure shall be conducted in its entirety and corrections submitted to the Marine Safety Center. 46 CFR 61.40-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 6 November 2023
Resolution: Cleared
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 18 January 2018
Resolved
Leak present in transverse bulkhead at frame 62 in way of starboard fuel oil day tank (#18) and starboard ballast tank (#20), allowing ballast water to leak into fuel tank.
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 8 January 2019
Resolution: Observed proper repairs.
Engineering › Fuel Oil Service System › Piping
Issued 21 October 2015
Resolved
Make permanent repairs to starboard main diesel engine fuel line piping so that it operates as required by CFR regulations. Additionally, please provide technical report detailing causal reasoning for failure of fuel line system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2015
Resolution: Proper repairs were made to starboard main diesel engine fuel line.
Construction/Loadline › Hull › Stiffener
Issued 5 June 2014
Resolved
Provide repair proposal for inset, buckled frames (transverse/longitunal) side shell plating, etc IWO fr 84, void #22 portside aft.
Due 13 June 2014
Resolved 12 June 2014
Resolution: Receive repair proposal to make permenant with 90days.
Construction/Loadline › Structures › Deck Plating
Issued 5 June 2014
Resolved
Make permenant repairs and replace all damage steel in #22 void port side aft, IWO fr 84.
Action required: 705 - Other - as specified
Due 9 September 2014
Resolved 29 August 2014
Resolution: Permenant repairs completed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 July 2009
Resolved
Properly seal all wire penetrations stbd side IWO bot thruster and engine room doors. Ensure proper rise system is installed.
Action required: 705 - Other - as specified
Due 15 July 2009
Resolved 13 July 2009
Resolution: Wire penetrations were properly sealed and proper rise system was installed.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 8 July 2009
Resolved
Ensure proper International Loadline Certificate is placed on board vessel. Provide a copy to local OCMI upon receipt.
Action required: 705 - Other - as specified
Due 15 July 2009
Resolved 13 July 2009
Resolution: International Loadline Certificate was placed on board, and a copy was provided to local OCMI.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 8 July 2009
Resolved
Replace sheathing stbd side of bow thruster room IWO overhead at the thruster muffler. Ensure pipe penetrations are sheathed as well.
Action required: 705 - Other - as specified
Due 8 August 2009
Resolved 13 July 2009
Resolution: Sheathing was replaced IWO overhead and pipe penetrations.
Fire Fighting › Fire Hoses › Length
Issued 8 July 2009
Resolved
Install adequate length of fire hoses in cargo area port side to perform proper firefighting entry.
Action required: 705 - Other - as specified
Due 8 August 2009
Resolved 27 July 2009
Resolution: Adequate fire hose length in cargo area on the port side installed.