Records from 1992 to 2025. Most recent: inspection, 2 September 2025.
Inspection history · 70
2 September 2025
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8236330
13 July 2025
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8217652
11 February 2025
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8077986
1 November 2024
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8028348
26 October 2024
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8031282
24 June 2024
TPO Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7942337
7 January 2024
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7847198
3 January 2024
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7844991
14 December 2023
Initial Certification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7838712
18 July 2023
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7751193
19 March 2021
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7159302
9 August 2017
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6240404
31 October 2016
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6032612
31 October 2015
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5755880
4 October 2015
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5738442
26 January 2015
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5059692
20 July 2014
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4985448
27 February 2014
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4807265
4 March 2013
Industry Initiated Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4543544
2 March 2011
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3959579
23 May 2010
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3748349
25 January 2010
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3670169
11 June 2009
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3578400
24 May 2009
Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3485985
24 May 2009
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3489024
25 January 2009
Administration
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3399698
8 December 2008
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3377002
10 June 2008
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3234142
4 June 2008
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3226956
1 April 2008
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3178965
15 February 2008
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3148256
7 February 2008
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3147614
2 October 2007
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3085982
5 November 2006
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2815450
15 September 2006
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2779328
24 May 2005
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2367249
17 February 2005
MTSA Verification · Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2295056
14 February 2005
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2295124
14 December 2004
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2269118
3 June 2004
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2092222
17 April 2004
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2048450
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1989918
25 August 2003
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1895910
19 April 2002
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1619643
26 September 2000
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 282583
16 September 2000
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 105720
2 December 1999
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 275088
15 October 1999
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 37657
26 September 1999
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 154713
25 July 1999
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 20367
23 April 1999
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 64149
9 April 1998
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 420869
15 April 1997
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 180913
10 February 1996
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 101959
11 January 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 32989
11 October 1995
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 173449
5 September 1995
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 84291
4 August 1995
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 147043
19 January 1995
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 41827
29 August 1994
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 9417
4 July 1994
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 174641
8 April 1994
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 43568
20 February 1994
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 46828
16 January 1994
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 11843
23 September 1993
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 30740
19 August 1992
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 62790
3 August 1992
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 4656
23 July 1992
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 11650
23 March 1992
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 143456
9 February 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 179467
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 1 November 2024
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. Hole found in piping in STBD #3 FUEL TANK. Repair IAW company TSMS. The vessel's TPO has the option to clear this deficiency in accordance with CG-CVC Policy Letter 17-10. Objective evidence attesting to root cause & satisfactory repairs must be submitted to local OCMI within 72-hours.
46CFR140.205
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 November 2024
Resolution: Received objective evidence of satisfactory repairs from TPO.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 January 2024
Resolved
The owner, managing operator, or master of a towing vessel must ensure that the vessel's lifesaving and fire suppression and detection equipment equipment complies with the applicable requirements and is in good working order. Vessel's fire detection panel is inoperable. Follow approved transit plan, make repairs to the satisfaction of the TPO. Provide objective evidence to the USCG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 January 2024
Resolved 19 January 2024
Resolution: TPO report received. Attached.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 December 2023
Resolved
All seals and gaskets must be properly maintained to prevent leaks of combustible liquids. The port main engine is leaking lube oil from the exhaust manifold - to - engine mating surface to the point that lube oil is puddling on the engine valley. Make repairs prior to using the engine.
Action required: 705 - Other - as specified
Resolved 15 December 2023
Resolution: Verified the engine valleys were cleaned. The company implemented daily checks to ensure oil does not accumulate again.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 December 2023
Resolved
Propulsion machinery including shafting must be maintained to ensure proper operation. The port and starboard shaft seals a leaking excessively.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 December 2023
Resolution: Verified the seals were tightened and that the leak was slowed to a drip.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 14 December 2023
Resolved
Prior to getting underway for the first time on a particular towing vessel, each crew member must receive safety orientation covering the items in 46 CFR 140.410(c). The crew was not familiar with the location or operation of semi-portable fire extinguishing equipment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2023
Resolution: Verified that crew familiarization had taken place and witnessed a satisfactory fire drill in the engine room. Verified all crew members were knowledgeable regarding the location and operation of the semi portable fire extinguishers.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 December 2023
Resolved
A towing vessel must be maintained so the watertight integrity of the vessel is not compromised. There is a hole in the top of the stbd forward ballast tank allowing water to leak into the forward deck locker.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 December 2023
Resolution: Verified satisfactory repairs were made to the tank-top.