Records from 2007 to 2019. Most recent: inspection, 25 December 2019.
Inspection history · 23
25 December 2019
ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6876592
7 December 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6593578
13 September 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6539968
30 August 2018
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6527096
14 April 2016
COE-Administrative
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5851845
16 February 2016
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5815745
27 January 2016
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5804453
8 December 2015
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5772834
13 June 2014
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4889949
13 June 2014
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4907041
6 June 2014
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4877989
1 June 2012
NPV Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4330753
21 December 2011
ISPS III Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4212204
3 July 2011
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4066299
20 February 2009
MARPOL Annex I Examination · ISPS III Exam · COC-CHEM Renew · PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3420824
4 March 2008
MARPOL Annex V Examination · COC-CHEM Annual · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3157959
2 February 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3140733
3 July 2007
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2981741
2 June 2007
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2947837
22 April 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2912781
9 February 2007
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2869882
7 February 2007
COC-CHEM Renew · MARPOL Annex II Examination · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2868022
6 February 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2862993
Engineering › Compressed Air System (start air) › Valve
Issued 3 July 2011
Resolved
MDE shut-off several times during outbound transit. Pilots reported the incident to command center.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 3 July 2011
Resolved 3 July 2011
Resolution: MDEstarting air distributor and related control air system solenoid valves (2) were replaced with spares. Classification Society verified and approved repairs.
Deck/Cargo › Inert Gas System › Deck Mechanical Non-Return Valve
Issued 7 February 2007
Resolved
PIPING DIAGRAM GDZ-1709 CORRESPONDS TO THE INSTALLED IGS SYSTEM'S NON-RETURN VALVE ON THE CARGO SIDE OF THE DECK WATER SEAL. HOWEVER, THE DIAGRAM DOES NOT PROPERLY CORRESPOND TO THE INSTALLED POSITIVE STOPPING DEVICE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 9 February 2007
Resolution: Received proper documentation from Det Norske Veritas satisfying requirement.