MAURY USCG vessel records
← All vessels

JALMA TOPIC

JALMA TOPIC is a 2006 freight ship. The Coast Guard has recorded 20 inspections since 2016, most recently in July 2025, along with 6 deficiencies and 6 operational controls, 1 with no removal date recorded.

Records from 2016 to 2025. Most recent: inspection, 16 July 2025.

Built
2006
Last inspected
16 July 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 July 2025
…with no type recorded6
Operational controls 1 with no removal date recorded
Years with a record 7 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9309655
872047
Flag
LIBERIA
Maury page id
psix-872047

Documentation record

Tonnage as PSIX records it30369 - Convention (Subpart B), Gross Ton
17907 - Convention (Subpart B), Net Ton
60772 - Displacement, Metric Ton
51966 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

20 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; 6 operational controls with the dates imposed and removed; 3 vessels inspected with it, by name and date; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ERVIN S. COOPER Towing Vessel · MISLE 74159 · 12 July 2021 · activity 7253511ANGUS R. COOPER Towing Vessel · MISLE 85820 · 12 July 2021 · activity 7253511MARDI GRAS Towing Vessel · MISLE 1374916 · 12 July 2021 · activity 7253511

Inspection history · 20

16 July 2025 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8177982
5 November 2024 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8028097
5 November 2024 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8029953
4 November 2024 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8033529
17 June 2023 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7717009
17 March 2023 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7652559
23 February 2022 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7401153
14 September 2021 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7298190
13 August 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7286066
12 July 2021 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7253456
12 July 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7253511
25 June 2021 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7228944
14 May 2021 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7191597
13 May 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7196488
6 March 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6637278
20 February 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6628764
16 November 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6038173
3 February 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5808697
30 January 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5806588
17 January 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5797493

Deficiency record · 6

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 5 November 2024 Resolved
Each survival craft shall be stowed fully equipped as required by the code; lifeboat equipment shall consist of watertight receptacles containing a total of 3L of fresh water for each person the lifeboat is permitted to accommodate. PSCO observed approximately 40% of required quantity of water expired. Action taken by crew to provide temporary jugs of water in lifeboat until order of compliant water was delivered. 74 SOLAS (2020 CONS) CH III/13.1.4 LSA Code. Rectified, Code 10c.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 December 2024
Resolved 5 November 2024
Resolution: Crew provided adequate water requirements for lifeboat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 July 2021 Resolved
Where the main steering great comprises two or more identical power units. an auxiliary steering gear need not be fitted, provided that in a cargo ship, the main steering gear is capable of of operating the rudder as required by paragraph 3.2 while operating with all power units. PSCO observed steering pump #1 unable to return to any STBD direction after going port. 74 SOLAS (04) II-1/29.6.1.2
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 July 2021
Resolution: Reviewed and accepted class report from LR. The report stated there was a defect relay contact for port feedback operation signal on pump #1. Tech replaced parts, and class witnessed satisfactory test.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 July 2021 Resolved
Ships shall comply with an intact stability standard acceptable to the Administration. PCO observed penetration to hull following marine casualty. ICLL (88) 1.3
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 July 2021
Resolution: Reviewed and accepted class report from LR. The report stated a repair company was hired to completed necessary repairs to FWD Ballast Peak Tank. LR witnessed pressure test with 1.5Bar and NDE on the bow shell plate in 100% of the rewelded area.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 May 2021 Resolved
A FIXED FIRE DETECTION AND FIRE ALARM SYSTEM SHALL BE PROVIDED IN ACCORDANCE WITH THE PROVISIONS OF THIS REGULATION. PSCO OBSERVED SMOKE ALARM NUMBER 14 INOPERABLE AND DISABLED ON FIRE ALARM PANEL. 74SOLAS(14) II-S/7.2.1 (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 May 2021
Resolved 16 May 2021
Resolution: Vessel sent in a class report stating vessel's Fire Detection system has been repaired and is completely operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 February 2019 Resolved
After any survey of the ship has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the Administration. A barrel of cylinder oil was discovered soft piped into the main engine lubricating system. (74) SOLAS Chapter I, Reg 11(b) -Rectify to satisfaction of CG and Class.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2019
Resolved 6 March 2019
Resolution: Received, reviewed and accepted documentation from class LLoyd. Crew replaced plastic pipe with steal.
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 20 February 2019 Resolved
Oil filtering equipment shall be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when oil content of effluent exceeds 15ppm. Port State Control Officer observed, while testing oily water separator, ship's crew could not get a sample of outboard effluent through oil content meter. MARPOL Annex I Reg 14.7.-Rectify to satisfaction of CG and Class.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2019
Resolved 6 March 2019
Resolution: Received, reviewed and accepted documentation from class Lloyds. Ships crew replaced sample tubing with satifactory test by class.