Records from 2007 to 2025. Most recent: inspection, 16 July 2025.
Inspection history · 26
16 July 2025
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8177982
5 November 2024
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8028097
5 November 2024
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8029953
4 November 2024
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8033529
17 June 2023
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7717009
17 March 2023
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7652559
23 February 2022
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7401153
14 September 2021
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7298190
13 August 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7286066
12 July 2021
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7253456
12 July 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7253511
25 June 2021
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7228944
14 May 2021
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7191597
13 May 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7196488
6 March 2019
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6637278
20 February 2019
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6628764
16 November 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6038173
3 February 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5808697
30 January 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5806588
17 January 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5797493
29 July 2015
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5198098
25 July 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4382811
29 January 2010
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3669770
10 August 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3286562
8 February 2007
MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2868869
8 February 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2868983
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 5 November 2024
Resolved
Each survival craft shall be stowed fully equipped as required by the code; lifeboat equipment shall consist of watertight receptacles containing a total of 3L of fresh water for each person the lifeboat is permitted to accommodate. PSCO observed approximately 40% of required quantity of water expired. Action taken by crew to provide temporary jugs of water in lifeboat until order of compliant water was delivered. 74 SOLAS (2020 CONS) CH III/13.1.4 LSA Code. Rectified, Code 10c.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 December 2024
Resolved 5 November 2024
Resolution: Crew provided adequate water requirements for lifeboat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 July 2021
Resolved
Where the main steering great comprises two or more identical power units. an auxiliary steering gear need not be fitted, provided that in a cargo ship, the main steering gear is capable of of operating the rudder as required by paragraph 3.2 while operating with all power units. PSCO observed steering pump #1 unable to return to any STBD direction after going port. 74 SOLAS (04) II-1/29.6.1.2
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 July 2021
Resolution: Reviewed and accepted class report from LR. The report stated there was a defect relay contact for port feedback operation signal on pump #1. Tech replaced parts, and class witnessed satisfactory test.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 July 2021
Resolved
Ships shall comply with an intact stability standard acceptable to the Administration. PCO observed penetration to hull following marine casualty. ICLL (88) 1.3
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 July 2021
Resolution: Reviewed and accepted class report from LR. The report stated a repair company was hired to completed necessary repairs to FWD Ballast Peak Tank. LR witnessed pressure test with 1.5Bar and NDE on the bow shell plate in 100% of the rewelded area.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 May 2021
Resolved
A FIXED FIRE DETECTION AND FIRE ALARM SYSTEM SHALL BE PROVIDED IN ACCORDANCE WITH THE PROVISIONS OF THIS REGULATION. PSCO OBSERVED SMOKE ALARM NUMBER 14 INOPERABLE AND DISABLED ON FIRE ALARM PANEL. 74SOLAS(14) II-S/7.2.1 (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 May 2021
Resolved 16 May 2021
Resolution: Vessel sent in a class report stating vessel's Fire Detection system has been repaired and is completely operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 February 2019
Resolved
After any survey of the ship has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the Administration. A barrel of cylinder oil was discovered soft piped into the main engine lubricating system. (74) SOLAS Chapter I, Reg 11(b) -Rectify to satisfaction of CG and Class.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2019
Resolved 6 March 2019
Resolution: Received, reviewed and accepted documentation from class LLoyd. Crew replaced plastic pipe with steal.
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 20 February 2019
Resolved
Oil filtering equipment shall be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when oil content of effluent exceeds 15ppm. Port State Control Officer observed, while testing oily water separator, ship's crew could not get a sample of outboard effluent through oil content meter. MARPOL Annex I Reg 14.7.-Rectify to satisfaction of CG and Class.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2019
Resolved 6 March 2019
Resolution: Received, reviewed and accepted documentation from class Lloyds. Ships crew replaced sample tubing with satifactory test by class.
Fire Fighting › Structural - A Class Divisions › Hose Ports
Issued 29 July 2015
Resolved
"A" class divisions are insulated with approved non-combustible materials. Vessel found to have multiple openings in cable room wire runs that penetrate class "A" bulkheads.SOLAS (14 Cons) CH II-2 Reg 3.2.3; 40(a)(c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 January 2016
Resolution: PSC NOLA received a report from Flag satisfying the requirement.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 29 July 2015
Resolved
Cargo ships when engaged on international voyages shall be fitted with VDR. Vessel VDR is inoperable. SOLAS (14 Cons) CH V Reg 20.2 - 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 January 2016
Resolution: PSC NOLA received a service report from Furuno satisfying the requirement.
Fire Fighting › Remote Fuel Shutoff › General
Issued 29 July 2015
Resolved
Auxiliary machinery shall be provided with automatic shutoff arrangements. Emergency Generator is unable to shutoff due to faulty emergency shutoff valve. SOLAS (14 Cons) CHII-1 Reg. 27.5 - 50AC: 30 days
Due 28 August 2015
Resolved 17 January 2016
Resolution: PSC NOLA received a report from Flag satisfying the requirement.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 29 July 2015
Resolved
The company and the ship shall comply with the ISM Code. The requirements of the code shall be treated as mandatory. vessel safety management system CH11 states all machinery and equipment within in the vessel are maintained with in relevant codes and regulations. Vessel failed to provide machinery records. SOLAS (14 Cons) CH IX Reg 3.1 - 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 January 2016
Resolution: PSC NOLA received a report from Flag satisfying the requirement.