Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBOLLINGER MARINE FABRICATORS LLC · AMELIA, LA, UNITED STATES · built 2008
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un, reg_nfv
DocumentationValid · issued 14 March 2026 · expires 30 April 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Gross Ton 1754 - Simplified, Net Ton 5174 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 35 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 4 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 September 2024Resolved
Gears, couplings, flywheels and all machinery capable of injuring personnel shall be provided with adequate covers or guards. Inspector observed #1 and #2 accessory drive belt cargo pump engines operating without proper machinery guards.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 October 2024
Resolved 12 September 2024
Resolution: Operator provided photos of installed belt guards.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 June 2023Resolved
Nonmetallic flexible hoses may be used in fuel oil systems only where flexibility is required and in lengths not exceeding 30 inches. The flexible hose acting as the diesel fuel return line for the port side cargo pump engine exceeded 30 inches. 46 CFR 56.60-25(b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 July 2023
Resolution: New hard piping installed and leak tested for both cargo pump engines. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 June 2023Resolved
Semi-portable fire extinguishers must be fitted with a suitable hose and nozzle, or other practicable means, so that all portions of the space concerned can be protected. The fire extinguisher assigned to the cargo deck lacked the proficient hose length to cover its entire assigned area. Rectify in seven days. 46 CFR 34.50-10(g)
Action required: 705 - Other - as specified
Resolved 19 July 2023
Resolution: Observed placement of new semi-portable fire extinguisher to cover the remaining area of the cargo deck. All sat.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 24 August 2021Resolved
All electrical installations in hazardous locations must comply with the general requirements of section 33 of IEEE 45-1998.
The bellows covering the cargo pump shafts were wasted at both cargo pumps. This opened the machinery space, which contains electrical equipment not rated class 1 division 1, to the hazardous zone.
Attending inspectors verified that electrical equipment not rated class 1 division 1 was removed from both machinery spaces, that outlets were properly plugged, and that new bellows were on order.
46 CFR 111.105-3, 10c
Action required: 10 - Deficiency Rectified
Resolved 24 August 2021
Resolution: Attending inspectors verified that electrical equipment not rated class 1 division 1 was removed from both machinery spaces, that outlets were properly plugged, and that new bellows were on order.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 7 December 2020Resolved
Venting system including vent header was mechanically secured during transfer. Venting system is required to be used during transfers. (Venting system was secured because tank hatches were open but unsupervised and without flame screens.)
Condition: Placed in Improper Service
Action required: 703 - Prior to bunkering operations
Due 7 January 2021
Resolved 7 December 2020
Resolution: The hatches were secured and the venting system was set up properly prior to end of in service inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 7 December 2020Resolved
Cargo tank ullage hatches were open during a transfer of premium gasoline without immediate supervision by PIC and without flame screens present.
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 6 January 2021
Resolved 7 December 2020
Resolution: Prior to transfer monitor team leaving the vessel the tank hatches were closed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2019Resolved
Each ungrounded system must be provided with a ground detection system which provides continuous indication of the circuit status.
There is a ground fault located on the 460V system in the port machinery space.
Action required: 705 - Other - as specified
Resolved 17 July 2019
Resolution: Ground fault cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2019Resolved
Each vessel must carry life jackets for each person on board.
There were no life jackets on board in operational condition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2019
Resolution: Installed life jackets IAW 46CFR.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 15 July 2019Resolved
Each life raft must be arranged for float free launching.
The life raft painter line was secured to the pelican hook and not to the weak link of the hydrostatic release unit, preventing proper life raft deployment.
Action required: 10 - Deficiency Rectified
Resolved 15 July 2019
Resolution: Porperly attached painter to weak link of float free arrangement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 July 2019Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use.
The lifebuoy and lifebuoy light on starboard bow were inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2019
Resolution: Installed new lifebuoy and light.
Vessels anchor struck the hull causing a 1 x 8 inch crack. Vessel must repair prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2019
Resolution: Repair completed.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 11 April 2018Resolved
Correct ground at potable water tank heater.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 22 June 2018
Resolution: Recieved technician report stating that the ground was corrected and the ground detection is working properly onboard.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 23 April 2014Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has 0.5 inch diameter and is at least 1 inch long. It must be located at the top of the flange face, midway between bolt holes [...]. Port and starboard vapor connection flange faces are missing the required permanent stud. 46CFR39.2001(J)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 June 2014
Resolved 14 May 2014
Resolution: Received email showing the proper installation of the vapor connection flange having a permanent 12 o''clock stud.