MAURY USCG vessel records
← All vessels

JAEGER

JAEGER is a 2004 freight ship. The Coast Guard has recorded 14 inspections since 2016, most recently in October 2022, along with 8 deficiencies — 1 with no resolution recorded — and 3 operational controls.

Records from 2016 to 2022. Most recent: inspection, 31 October 2022.

Built
2004
Last inspected
31 October 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 31 October 2022
…with no type recorded5
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9284843
872644
Flag
MARSHALL ISLANDS
Maury page id
psix-872644

Documentation record

Tonnage as PSIX records it30012 - Convention (Subpart B), Gross Ton
17843 - Convention (Subpart B), Net Ton
60772 - Displacement, Metric Ton
52483 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ANGUS R. COOPER Towing Vessel · MISLE 85820 · 22 June 2022 · activity 7484317JOSEPHINE ANNE Towing Vessel · MISLE 878010 · 22 June 2022 · activity 7484317MICHAEL S Towing Vessel · MISLE 1016499 · 22 June 2022 · activity 7484317

Inspection history · 14

31 October 2022 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7581818
11 October 2022 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7576398
5 October 2022 Deficiency Check · PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7570789
22 June 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7484317
22 June 2022 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7484366
22 June 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7484502
1 February 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7376622
11 January 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7378948
25 November 2020 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7102241
24 November 2020 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7101708
24 May 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6419682
3 August 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5961315
4 March 2016 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5826977
5 January 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5791623

Deficiency record · 8

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 October 2022 No resolution recorded
Efficient guard rails or bulwarks shall be fitted to all exposed parts of the freboard and superstructure decks. PSCO observed damaged railing on both port and starboard sides. ICLL 25(2)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 December 2022 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 31 October 2022 Resolved
The following fire protection ssytems shall be kept in good order; means of escape and appliances. PSCO observed partially empty EEBD M/E adjacent. SOLAS(20) II-2/14.2.1.1.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 October 2022
Resolved 31 October 2022
Resolution: Partially empty EEBD was replaced with a full EEBD.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 October 2022 Resolved
All life saving appliances shall be in working order and ready for immediate use. PSCO observed three inoperable self-righting lights. 74SOLAS(20) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 October 2022
Resolved 31 October 2022
Resolution: Light bulbs and batteries were replaced in the faulty self-righting lights.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 October 2022 Resolved
The Company should establish procedures for the implementation of corrective action, including measures intended to prevent recurrence; while onboard conducting a PSC Exam the PSCO found objective evidence to suggest vessel and company have knowingly lost seal oil from shaft seal utilizing "Stern Tube Brg and Air Seal Guard" log as well as the Oil Record Book. Ship's crew has added oil for several months to a closed system without identifying source of leak. Additionally, emails between vessel and Company show problem has existed since at least April 2022 w/ no resolution. An External ISM is to be conducted and a Corrective Action plan submitted prior to the vessel departing the Port of Wilmington, NC. 74 SOLAS (2020 Cons) IX/3.1 ISM Code A/9.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 20 October 2022
Resolution: An external was conducted by Marshall Islands. Doc is uploaded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2022 Resolved
The machinery and associated piping systems and fittings shall be of a design adequate for the service intended; vessel's stern tube seal is leaking. Vessel must submit plan for repair. 74 SOLAS (04) II-1 26.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2022
Resolution: Stern tube seal replaced; tech report uploaded
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 October 2022 Resolved
In addition to complying w/ specific provisions fro fire integrity of bulkheads, ships shall meet the minimum fire integrity requirements in tables 9.5 and 9.6; A-0 door threshold separating galley and scullery is rotted. 74 SOLAS (04) II-2 9.2.3.3.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 October 2022 Resolved
Suitable pressure relief arrangements shall be provided for all air pressure systems; two ship's air receivers in engine room do not have relief devices installed. 74 SOLAS (04) II-1 34
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 June 2022 Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. Vessel suffered marine casualty and anchored at New Orleans General Anchorage. PSCO observed bridge and engine control room operational control failure of main engine. 74 SOLAS (2004)II-1/31.1 60ac
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 22 June 2022
Resolved 24 June 2022
Resolution: Received, reviewed and accepted class report from LR stating the deficiency was rectified. Pressure switch for MAIN LO LOW PRESS SLOWDOWN (MLOS) was found grounded and replaced by crew. M/E tested satisfactorily by class.

Ownership record