MAURY USCG vessel records
← All vessels

MMI 3059

Built
2007
Last inspected
31 July 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 31 July 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 14 calendar years (2007–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

874300
Flag
UNITED STATES
Maury page id
psix-874300

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · MADISONVILLE, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portHOUSTON, TX
Endorsements, as the file codes themcw_un
DocumentationValid · issued 28 May 2026 · expires 30 June 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 20 inspections, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 6 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 6

Inspection history · 20

31 July 2026 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8451697
21 April 2025 Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8118379
10 April 2025 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8109690
31 January 2020 MTSA Verification · Examination of Repairs · COI Inspection · Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6895399
1 May 2019 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6674706
18 July 2016 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5938130
2 September 2015 Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 5234097
27 October 2014 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5011605
20 June 2013 Examination of Repairs · Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4618200
7 August 2012 MTSA Verification · COI Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4403547
13 July 2011 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4080082
11 August 2010 Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3821334
16 June 2009 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3506271
20 March 2009 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3436917
4 March 2009 Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3427742
3 March 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3430262
25 November 2008 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3369798
23 July 2008 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3276882
5 September 2007 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3049439
26 July 2007 Administrative Inspection · Hull Examination · MTSA Verification · Initial Certification · Initial Construction-Excluding Oversight · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2908852

Deficiency record · 4

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 31 July 2026 Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping. Vessel self reported two inch hole in cargo tank stripping line, repaired using temporary patch. Vessel is authorized to discharge cargo on board before enacting permanent repairs to the satisfaction of the Coast Guard. 46 CFR 32.60-1(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 August 2026
Resolution: Stripping line was removed. Pictures provided were deemed satisfactory.
Construction/Loadline › Hull › Side Shell
Issued 4 March 2009 Resolved
A 10'x6' smooth inset observed port side in way of #4 wing void, just below rub bar. Depth of the inset is 0'-4'. Made visual inspection of #4 wing void. Noted one bay largely effected, with #3 truss side chord taking brunt of impact. There is some damage to the floor frame, diagonal and horizontal angles in way of chord as well. The #4 truss side chord also has some damage.
Action required: 705 - Other - as specified
Due 6 May 2009
Resolved 20 March 2009
Resolution: Conducted repair check. Examined welds and witnessed satisfactory air test of a 10'' x 6'' x 3/8" side shell insert to the #4 port wing void.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 26 July 2007 Resolved
Provide proof of Vessel Response Plan with CG approval letter to the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2007
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 26 July 2007 Resolved
Apply all required markings to vessel (i.e. draft marks, vapor pipe markings, vessel name etc.)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2007

Ownership record