MAURY USCG vessel records
← All vessels

RTC 80

Built
2007
Last inspected
22 November 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 22 November 2025
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 19 calendar years (2007–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCX3683
874374
Flag
UNITED STATES
Maury page id
psix-874374

Documentation record

Registered dimensions (L × B × D)326.5 ft × 74.0 ft × 26.5 ft
Registered tonnagegross 5,405 / net 5,405
ITC dimensions (L × B × D)326.5 ft × 74.0 ft × 26.5 ft
ITC tonnagegross 5,770 / net 3,854
BuilderSENESCO MARINE INC · NORTH KINGSTOWN, RI, UNITED STATES · built 2007
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 10 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5405 - Regulatory (Subpart C or D), Gross Ton
5770 - Convention (Subpart B), Gross Ton
2155 - Displacement, Gross Ton
11692 - Dead Weight, Gross Ton
5405 - Regulatory (Subpart C or D), Net Ton
3854 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 42 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 4 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

Inspection history · 42

22 November 2025 Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8273149
29 July 2025 Periodic Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8197383
15 May 2025 Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8133119
12 November 2024 Bulk Liquid Transfer Monitor
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8034228
16 July 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7959662
29 March 2024 Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7886763
13 June 2023 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7714070
18 December 2022 Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7610593
16 December 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7610217
16 December 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7612321
20 July 2022 Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7511957
27 June 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7488965
9 May 2022 COI Inspection · Drydock Exam · Internal Structural Exam · Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7425586
19 September 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7322288
20 June 2021 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7233642
1 June 2021 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7211753
19 June 2020 Annual Inspection · Internal Structural Exam · MARPOL Annex II Examination · MARPOL Annex IV Survey · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6981456
22 January 2020 Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6897699
9 September 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6807672
8 August 2019 Periodic Inspection · MARPOL Annex I Examination · MTSA Verification · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6776481
6 November 2018 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6575452
30 June 2017 MARPOL Annex VI Survey · MARPOL Annex I Examination · MARPOL Annex II Examination · MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6190791
10 May 2017 Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6142795
26 July 2016 MARPOL Annex VI Survey · MARPOL Annex II Examination · MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5953230
22 September 2015 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5725312
5 May 2015 MARPOL Annex I Examination · Periodic Inspection · MARPOL Annex VI Survey · MARPOL Annex II Examination · Internal Structural Exam · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5117753
2 July 2014 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4908100
29 March 2014 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4826360
24 July 2013 Annual Inspection · MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex II Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4663498
31 December 2012 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4509772
7 June 2012 MARPOL Annex I Examination · COI Inspection · MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex II Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4334804
14 May 2012 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4310874
1 July 2011 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4064010
10 May 2010 Periodic Inspection · MTSA/ISPS Verification · Internal Structural Exam · MARPOL Annex I Examination · MARPOL Annex II Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3732987
6 April 2010 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3724590
25 February 2009 Administrative Inspection · Annual Inspection · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3423812
12 September 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3324483
5 August 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3297193
11 July 2008 Annual Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3264260
19 May 2008 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3211216
27 August 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3056518
1 March 2007 Initial Certification · MTSA Verification · Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2879777

Deficiency record · 6

02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 15 May 2025 Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the assigning authority. Each gasket for the ballast tank manholes must be replaced, including the aft peak port side opening. Mating surfaces on all ballast tank manholes are in need of descaling.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 19 May 2025
Resolution: All sat.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 15 May 2025 Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the assigning authority. The gasket for the 1P sounding tube is worn and must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 19 May 2025
Resolution: All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2025 Resolved
Pressure vessels must be designed, constructed, and inspected in accordance with Section VIII of the ASME BPVC (incorporated by reference, see § 54.01-1). Marine inspector observed multiple holes on the press/vac tank's forward chamber in way of the manhole. Significant corrosion was found in the same area of the aft chamber. Press/vac tank must be locked out and tagged out until satisfactory repairs are complete. Submit repair proposal for approval IAW ASME BPVC.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 September 2025
Resolution: Boarded vessel, MIs noted the vacuum tank was removed from the vessel
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 24 June 2022 Resolved
Flame screens located in P/V relief valve vent pipe are damaged/holed. Renew flame screens prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 June 2022
Resolved 27 June 2022
Resolution: Operator installed new flame screens.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 24 June 2022 Resolved
Relief valves located on the vac/pressure tank are missing flame screens. Provide flame screens prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 June 2022
Resolved 27 June 2022
Resolution: Operator installed new flame screens on vac tank relief valves.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 March 2007 Resolved
Provide original certificate of documentation for the barge. To be completed via FAX to Sector SE New England but no later than 15 May 07
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 14 May 2007

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.