Records from 2007 to 2017. Most recent: inspection, 18 August 2017.
Documentation record
Registered dimensions (L × B × D)221.7 ft × 54.0 ft × 18.0 ft
Registered tonnagegross 1,863 / net 558
ITC dimensions (L × B × D)221.7 ft × 54.0 ft × 18.0 ft
ITC tonnagegross 1,863 / net 558
BuilderATLANTIC MARINE FLORIDA LLC · JACKSONVILLE, FL, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 21 July 2026 · expires 31 August 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1863 - Convention (Subpart B), Gross Ton
2758 - Dead Weight, Gross Ton
558 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 12
18 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6244694
2 October 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4997747
1 October 2014
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4995730
20 July 2012
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4385092
18 June 2012
SIP Inspection/Audit · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4348382
20 July 2009
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3540778
9 July 2009
Administrative Inspection · SIP Initial Entry
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3528820
10 April 2009
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3449919
19 September 2008
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3340776
30 July 2008
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3284153
27 November 2007
Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3105113
11 June 2007
MTSA/ISPS Verification · Hull Examination · Initial Certification · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2958535
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 2 May 2008
Resolved
Main switchboard insulation monitor indicates a dead ground. Troubleshooting reveals grounds are isolated to the ships service generators. (Ground detector light do not indicate ground). Repair insulation monitor to the satisfaction of the attending CG Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 19 September 2008
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 2 May 2008
Resolved
Machinery and Aux spaces, electric motors are rated at 40 C, not the 50 C rating required by CFR, IEEE-45, and Class Rules. Provide documentary proof of the required motors ambient temperature rating to the satisfaction of the attending CG marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 30 July 2008
Resolution: Received documentation for all electric motors on board that indicates an ambient temp rating of 50C, informed vessel operator that a copy of these data sheets should remain onboard for future reference. All Sat.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 2 May 2008
Resolved
Locate, isolate and repair ground on 12v/208v a/c panel in bow thruster space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 July 2008
Resolved 2 May 2008
Resolution: Properly replaired ground in wall outlet for the galley hot food serving tray. All Sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 May 2008
Resolved
Aft two man sateroom on 01 deck has inadaquate lighting installed. Install additional lighting as required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 19 September 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2008
Resolved
Properly install cabling (electrical) and power supply under forward pilothouse console.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 19 September 2008
Electrical › Electrical Distribution System (service) › Cable
Issued 2 May 2008
Resolved
Properly band electrical cables in pilothouse closet and 01 deck trunk.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 19 September 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2008
Resolved
Install wire and calbe circuit tags throughout the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 19 September 2008
Electrical › Electrical Distribution System (service) › Panelboard
Issued 2 May 2008
Resolved
Clean trash and debris from under pilothouse console.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2008
Resolved 19 September 2008
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 2 May 2008
Resolved
Provide pipe supports for water supply lines to all toilets throughout the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 19 September 2008
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 May 2008
Resolved
Properly label all valves and vents throuhout the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 19 September 2008
Fire Fighting › Structural - B Class Divisions › Accommodation Spaces
Issued 11 June 2007
Resolved
Air handler rooms on foc/sle and 01 decks need wire penetrations and fresh air ducts sealed properly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 19 September 2008