NATIONAL ELITE

NATIONAL ELITE is a 2007 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 2007, most recently in July 2026, along with 46 deficiencies and 5 casualty investigations between 2008 and 2023.

Records from 2007 to 2026. Most recent: inspection, 28 July 2026.

Built
2007
Last inspected
28 July 2026
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP9782
889861
Flag
UNITED STATES
368401990
Maury page id
psix-889861

Inspections, by type

…with no type recorded3
Years with a record 16 calendar years (2007–2026)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)107.3 ft × 24.0 ft × 6.0 ft
Registered tonnagegross 78 / net 53
ITC dimensions (L × B × D)107.3 ft × 24.0 ft × 6.0 ft
ITC tonnagegross 301 / net 90
BuilderMID-CITY STEEL FABRICATING · LA CROSSE, WI, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNATIONAL HARBOR, MD
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationCase Pending · issued 15 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it78 - Regulatory (Subpart C or D), Gross Ton
301 - Convention (Subpart B), Gross Ton
128 - Displacement, Gross Ton
53 - Regulatory (Subpart C or D), Net Ton
90 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP9782MMSI 368401990 · active · compulsorily equipped · granted 25 January 2025, expires 25 January 2035
WDH8552MMSI 367659160 · expired · compulsorily equipped · granted 27 February 2015, cancelled 3 May 2025
WDF6968MMSI 367479740 · expired · compulsorily equipped · granted 19 February 2011, cancelled 24 April 2021 · licensed under a name not among this hull’s recorded names (not shown)
WDE2344MMSI 367323810 · expired · compulsorily equipped · granted 21 November 2007, cancelled 27 January 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CATALINA Passenger (Inspected) · MISLE 322975 · 17 May 2008 · activity 3218772

Inspection history · 35

28 July 2026 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8448769
29 June 2026 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8420371
21 April 2025 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8116925
10 September 2024 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7999836
6 September 2023 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7787563
3 May 2023 Damage Survey · In-Service Inspection · Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7681919
2 May 2023 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7680361
22 June 2022 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7476306
4 January 2022 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7375569
2 September 2021 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7302836
23 September 2020 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7063410
10 July 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6744292
7 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6503657
9 May 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6409271
12 July 2017 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6206890
23 March 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6136138
23 February 2017 Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6093609
14 February 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6083849
18 April 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5879520
7 March 2016 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5848974
4 February 2016 Plan Review "T" Boat
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5809488
18 June 2012 DAPI Audit · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4317478
4 May 2012 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4329922
14 February 2011 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3947443
8 May 2009 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3470126
27 April 2009 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3461842
12 January 2009 In-Service Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3392668
8 January 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3416773
16 November 2008 Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3365223
4 November 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3356906
30 July 2008 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3282699
19 May 2008 Damage Survey · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3210536
17 May 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3218772
20 November 2007 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3102103
2 July 2007 Deficiency Check · In-Service Inspection · Hull Examination · Internal Structural Exam · Initial Certification · Inclining Experiment · Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3091957

Deficiency record · 46

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 June 2026 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Aft Genset has an active oil leak from forward seal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2026
Resolved 28 July 2026
Resolution: Genset gasket was replaced. Leak has been mitigated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel incurred a loss of main engine power while underway. Vessel also damaged propeller while vessel didn't have control after running aground. Vessel authorized to operate under Conditional Restrictions. See Condtional Letter in Documents.
Action required: 705 - Other - as specified
Resolved 19 July 2023
Resolution: Satisfactory Sea Trial completed after shaft replacement
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 May 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel incurred a loss of main engine power while underway. Vessel also damaged propeller while vessel didn't have control after running aground. Determine cause of power loss and damage to propeller and prove proper operation of both to the satisfaction of the attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 May 2023
Resolution: Satisfatory Sea trial completed. Operational restrictions remain in place
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 7 August 2018 Resolved
Vsl is broadcasting: Invalid IMO #.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 September 2018
Resolved 17 October 2018
Resolution: Vessel met all requirements for AIS broadcasting.
Engineering › Bilge Water Management System › Strainer
Issued 12 June 2017 Resolved
Replace strainer in steering compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 19 June 2017
Resolution: Strainer was replaced.
Engineering › Bilge Water Management System › Valve
Issued 12 June 2017 Resolved
replace ball valve with screw down valve in bilge line aft of collision bulkhead
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 10 July 2017
Resolution: Received picture showing new screw down valve installed.
Communications › Alarms/Indicators › High Water Alarm
Issued 12 June 2017 Resolved
Install proper wire connectors on High Water Alarms.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 19 June 2017
Resolution: Proper connectors were installed.
Electrical › Electric Generation Source (service) › Generator
Issued 23 March 2017 Resolved
Number two generator had power failure.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2017
Resolved 31 March 2017
Resolution: Received appropriate tech/electrician reports
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 18 April 2016 Resolved
Connections found loose, provide tech report that system is fully functional and meet sesign specifications.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Resolution: Vessel provided tech report to the funtionality of the CO2 system.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 April 2016 Resolved
Line securing the light to the Life ring is no longer servicable.
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 20 April 2016
Resolution: Vessel provided digital picture of new line attaching light.
Electrical › Electric Generation Source (service) › Conductor
Issued 21 February 2016 Resolved
Provide approved plans for the newly installed John Deere SSDG. 1)Plan indicating type&size of SSDG to be installed 2)Plans indicating type&size of generator cables,breakers,over current devices 3)One line diagram 4) Load analysis.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2016
Resolution: Provided MSC approved plans.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 21 February 2016 Resolved
Provide approved plans for installed keel coolers to include: 1)Plans indicate the hull can structurally support installation of the keel coolers. 2)Plans showing installed 3/8" insert plate you installed to accommodate keel cooler piping penetrations.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2016
Resolution: Received MSC approvel plans.
Stability › Incline Test › General
Issued 21 February 2016 Resolved
Due to additional weight of keel coolers and weight differences between removed and installed SSDG; provide documentation from CGMSC attesting to the fact this vessel will still be operating within its Stablity Letter parameters once all work is completed.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2016
Resolution: Received MSC approval of installation of keel coolers.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 February 2016 Resolved
Reinstall CO2 system IAW approved plans for this system/vessel. Provide service report supporting the fact the system was reinstalled, pressure tested, installation tested IAW approved plans and standards.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2016
Resolution: Conducted dockside trials and recieved invoice and test report.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 21 February 2016 Resolved
Below systems were affected while completing work to your vessel. Operationally test these systems in the presence of a CG Marine Inspector: 1)Main Engines 2)Ships Generators 3)Bilge Pump/System-clutch driven off John Deere SSDG 4) Fire protection 5)Dockside&Underway Trials
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2016
Resolved 7 March 2016
Resolution: Conducted dockside trials, with Generator under full load, tested shut downs.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 18 June 2012 Resolved
Missing tourniquete kit in the first aid kit. 46 CFR 121.710
Due 6 July 2012
Resolved 27 June 2012
Resolution: Purchased tourniquete kit for first aid kit.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 14 February 2011 Resolved
Vessel is missing FCC Safety Radiotelephone Certificate and FCC Bridge-to-Bridge Certificate. Vessel is restricted to not more than 1,000 feet from shore until certificates are onboard.
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 18 March 2011
Resolution: FCC Safety Radiotelephone Certificate and FCC Bridge-to-Bridge Certificate provided onboard vessel.
Communications › Radio Communications › EPIRB
Issued 14 February 2011 Resolved
Vessel's EPIRB registration and hydrostatic release are both expired. Vessel is restricted to not more than 3 nautical miles from shore until new EPIRB is onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 18 March 2011
Resolution: EPIRB registration and hydrostatic release renewed.
Engineering › Feedwater/Condensate Water System › Tank
Issued 22 January 2009 Resolved
Prior to the carriage of passengers make proper repairs to FWD generator and show proper operation under load to attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 January 2009
Engineering › Feedwater/Condensate Water System › Tank
Issued 12 January 2009 Resolved
Prior to the carriage of passengers make proper repairs to aft generator and show proper operation under load to attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 January 2009
Engineering › Feedwater/Condensate Water System › Tank
Issued 12 January 2009 Resolved
Provide technician report that generators have been reinstalled IAW "Approved" plans and operate as designed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 January 2009
Engineering › Feedwater/Condensate Water System › Tank
Issued 12 January 2009 Resolved
Provide manufacture technician report on the cause of the generator failure to USCG Sector Miami.
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 21 May 2009
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 4 November 2008 Resolved
Third deckhand is not currently enrolled in company's drug testing program and must complete pre-enrollment drug testing and familiarization training.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 November 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 4 November 2008 Resolved
Master is not currently enrolled in company's drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 November 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 November 2008 Resolved
Conduct man-overboard and fire drills with proper crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 November 2008
Construction/Loadline › Structures › Superstructure
Issued 19 May 2008 Resolved
Make permenent/proper repairs to STBD bow door prior to 23May08.
Action required: 705 - Other - as specified
Due 23 May 2008
Resolved 27 May 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 January 2008 Resolved
Provide approved/as built electrical drawings. DWG 321-002 DC Electrical one line and DWG 321-001 AC Electrical one line diagram.
Action required: 705 - Other - as specified
Due 28 February 2008
Resolved 19 May 2008
Resolution: In file.
Electrical › Electric Generation Source (service) › Generator
Issued 28 January 2008 Resolved
Provide proof of generator temperature rating, (50 C).
Action required: 705 - Other - as specified
Due 28 February 2008
Resolved 19 May 2008
Resolution: In file
Construction/Loadline › Hull › Hull Plating
Issued 28 January 2008 Resolved
Dehumidifier overboard discharge piping must meet the requirements of 46 CFR 179.350. Install a positive closure device at the hull.
Action required: 705 - Other - as specified
Due 28 January 2008
Resolved 18 February 2008
Resolution: e-mail
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 26 November 2007 Resolved
Provide corrected/as built Electrical Plans, Vessel and approved plans must match.
Action required: 705 - Other - as specified
Due 28 February 2008
Resolved 28 January 2008
Resolution: reissued to new operator.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 November 2007 Resolved
Provide completed Application for Inspection and new Operator information.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2007
Resolved 26 November 2007
Resolution: onboard
Communications › Radio Communications › EPIRB
Issued 20 November 2007 Resolved
Provide proof of EPIRB NOAA registration.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2007
Resolved 26 November 2007
Resolution: onboard
Communications › Radio Communications › EPIRB
Issued 20 November 2007 Resolved
Punch out date on EPIRB Hydrostatic release.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2007
Resolved 26 November 2007
Resolution: onboard
Documentation › Certificates/Documents › FCC SSL
Issued 20 November 2007 Resolved
Provide proof of the following, FCC Station License, Radio Telephony Certificate, and Bridge to Bridge Certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2007
Resolved 26 November 2007
Resolution: onboard
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 November 2007 Resolved
Ensure PFD storage lockers are incapable to being locked.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2007
Resolved 26 November 2007
Resolution: onboard
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 20 November 2007 Resolved
Provide PFD's for 162 adults.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2007
Resolved 26 November 2007
Resolution: onboard
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 20 November 2007 Resolved
Conduct crew drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2007
Resolved 26 November 2007
Resolution: onboard
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 November 2007 Resolved
Provide original COD onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2007
Resolved 28 January 2008
Resolution: onboard
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 20 November 2007 Resolved
Provide proof and log required training.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2007
Resolved 26 November 2007
Resolution: onboard
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 November 2007 Resolved
Properly secure 2nd deck glass rail assembly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2007
Resolved 27 December 2007
Resolution: E-mail
Navigation › Piloting/Steering › Compass Deviation Table
Issued 20 November 2007 Resolved
Provide compass deviation table.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2007
Resolved 26 November 2007
Resolution: onboard
Lifesaving › Hand Flares › Quantity
Issued 20 November 2007 Resolved
Provide 06 red and 06 orange hand flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2007
Resolved 26 November 2007
Resolution: onboard
Electrical › Electric Generation Source (service) › Generator
Issued 20 November 2007 Resolved
Provide proof of generator temperature rating, (50 C).
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2008
Resolved 28 January 2008
Resolution: reissued to new operator.
Operations/Management › Passenger Operations › Safety Orientation
Issued 20 November 2007 Resolved
Provide resolution to "E-mail" items from Sector Upper Mississippi River.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2007
Resolved 28 January 2008
Resolution: onboard
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 20 November 2007 Resolved
Provide proof the Fire Pump motor meets the requirements of 46 CFR 183.320 (50 C).
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2007
Resolved 28 January 2008
Resolution: Email from Baldor
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 November 2007 Resolved
Prior to the carrying passengers for hire vessel shall conduct a COI inspection with Sector Miami, Florida. Items noted on list provided to Skipperliner Reps and noted on MISLE new construction narrative dated 12 Nov 2007 shall be corrected, cleared or extended as determined by the attending Marine Inspector and or OCMI.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 20 November 2007
Resolution: Conducted NTZ, issued 15 worklist items.

Casualty record · 5

17 May 2008Routine · role: Involved in a Marine Casualty · activity 3218772
8 January 2009Routine · role: Involved in a Marine Casualty · activity 3416773
24 March 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4555698
14 May 2013Routine · role: Involved in a Marine Casualty · activity 4592403
2 May 2023Routine · role: Involved in a Marine Casualty · activity 7680361
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

PRINCESS LADY (2008–2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.