MAURY USCG vessel records
← All vessels

STORM

Built
2005
Last inspected
20 July 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 20 July 2026
…with no type recorded13
Operational controls None recorded without a removal date
Years with a record 20 calendar years (2007–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9403358
J8B3609
890519
Flag
SAINT VINCENT AND THE GRENADINES
Maury page id
psix-890519

Documentation record

Tonnage as PSIX records it264 - Convention (Subpart B), Gross Ton
80 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 66 inspections, each with its date, unit and type; 77 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 4 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

Inspection history · 66

20 July 2026 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8442875
4 May 2026 PSC B · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8358616
3 January 2026 PSC B · CCSSC Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8289261
4 November 2025 PSC B · CCSSC Examination · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8261942
29 November 2024 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8042716
20 November 2024 CCSSC Examination · Deficiency Check · PSC B
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8036292
8 April 2024 Deficiency Check · PSC B · CCSSC Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7889509
27 July 2023 CCSSC Examination · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7749550
10 November 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7592737
12 October 2022 CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7574595
19 April 2022 CCSSC Examination · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7429392
19 April 2021 PSC B · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7174481
25 September 2020 CCSSC Examination · PSC B
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7065121
23 June 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6984458
17 March 2020 CCSSC Examination · PSC B
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6926190
8 September 2019 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6805954
6 September 2019 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6809510
3 September 2019 ISPS II Exam · CCSSC Examination · PII Safety Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6798893
7 June 2019 Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6706976
6 March 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6637022
1 March 2019 Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6634630
23 February 2019 MTSA/ISPS Verification · CCSSC Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6631030
15 February 2019 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6626325
18 January 2019 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6610983
14 November 2018 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6581820
22 September 2018 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6544585
17 September 2018 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6542229
16 August 2018 ISPS II Exam · PII Safety Exam · CCSSC Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6513159
14 July 2018 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6485521
9 February 2018 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6352568
27 November 2017 CCSSC Examination · Ballast Water Examination · PII Safety Exam · ISPS III Exam · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6313050
1 May 2017 ISPS II Exam · CCSSC Examination · Ballast Water Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6133211
25 January 2017 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6073998
21 November 2016 NPV Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6045284
8 October 2016 ISPS II Exam · CCSSC Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6018838
11 May 2016 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5873302
5 May 2016 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5869640
6 April 2016 CCSSC Examination · ISPS III Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5846079
21 October 2015 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5747858
2 October 2015 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5734251
30 September 2015 CCSSC Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5730654
17 September 2014 COE-Offshore
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4984580
17 September 2014 ISPS III Exam · PII Safety Exam · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4984586
10 January 2014 CCSSC Examination · ISPS II Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4779320
22 March 2013 PII Safety Exam · ISPS II Exam · CCSSC Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4554207
29 June 2012 CCSSC Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4360727
18 May 2011 ISPS II Exam · PII Safety Exam · CCSSC Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4015080
1 February 2011 ISPS II Exam · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3936976
24 October 2010 Deficiency Check · NPV Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3876669
22 October 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3874385
22 October 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3875202
15 September 2010 ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3850288
9 February 2010 PII Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3677318
8 February 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3676906
21 July 2009 ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3541404
21 January 2009 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3398315
7 May 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3201130
19 April 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3201060
25 February 2008 Random ISPS/MTSA-No PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3153212
15 October 2007 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3080384
17 July 2007 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2998325
17 July 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2998357
15 July 2007 Damage Survey
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2995248
22 June 2007 Security Plan Review - VSP
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2970101
15 June 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2962583
13 June 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2960589

Deficiency record · 77

02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 4 May 2026 Resolved
THE STRENGTH AND CONSTRUCTION OF HULL, SUPERSTRUCTURE, DECK HOUSES, MACHINERY CASINGS, COMPANION WAYS AND ANY OTHER STRUCTURE AND EQUIPMENT SHOULD BE SUFFICIENT TO WITHSTAND ALL FORESEEABLE CONDITIONS OF THE INTENDED SERVICE. PSCO OBSERVED THE GALLEY DOOR UNABLE TO FULLY CLOSE RENDERING THE CO2 PROTECTED SPACE UNABLE TO BE FULLY SECURED IN THE EVENT CO2 IS ACTIVATED. CCSSC 2.4.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 May 2026 Resolved
THE STRENGTH AND CONSTRUCTION OF HULL, SUPERSTRUCTURE, DECK HOUSES, MACHINERY CASINGS, COMPANION WAYS AND ANY OTHER STRUCTURE AND EQUIPMENT SHOULD BE SUFFICIENT TO WITHSTAND ALL FORESEEABLE CONDITIONS OF THE INTENDED SERVICE. BOTH STEERING GEAR WATERTIGHT HATCHES WERE UNABLE TO BE TO FULLY SECURED RENDERING THE THEM UNABLE TO TO BE FULLY WATERTIGHT. CCSSC 2.4.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2026
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 4 May 2026 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT IS MAINTAINED TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANDER TO THE SHIP OR PERSONS ON BOARD. [name withheld] CERTIFICATED STATING 04 SMOKE DETECTOR ASSIGNED TO THE MACHINERY SPACE. OBSERVED 01 OPERABLE SMOKE DETECTOR IN THE ENGINE ROOM. CCSSC 1.11.1 16C
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 6 May 2026
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 May 2026 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT IS MAINTAINED TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANDER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED 04 EMERGENCY LIGHTS WERE INOPERABLE. CCSSC 1.11.1 16C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 6 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 May 2026 Resolved
AT LEAST ONE LIFE BUOY ON EACH SIDE OF THE SHIP SHOULD BE FITTED WITH BUOYANT LIFE LINE OF AT LEAST 30 METERS. PSCO OBSERVED THE STARBOARD SIDE LIFEBOUY LIFELINE WAS DETORIORATED AND WOULD CRUMBLE WHEN TOUCHED. CCSSC 4.12.4 16C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 6 May 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2026 Resolved
MAIN AND EMERGENCY SWITCHBOARDS SHOULD BE SO ARRANGED AS TO GIVE EASY ACCESS AS MAY BE NEEDED TO APPARATUS AND EQUIPMENT WITHOUT DANGER TO PERSONNEL. PSCO OBSERVED SPACE BEHIND SWITCHBOARD USED AS STORAGE. CCSSC 2.27.2 16C
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 6 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 May 2026 Resolved
EVERY FIRE HOSE SHOULD BE PROVIDED WITH AN APPROVED NOZZLE AND THE NECESSARRY COUPLINGS. THE FIRE HOSE BOX LOCATED ON DECK 2 WAS MISSING A SPANNER WRENCH AND GASKET FOR THE NOZZLE. CCSSC 3.5.9 16C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 6 May 2026
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 4 May 2026 Resolved
THE STRENGTH AND CONSTRUCTION OF HULL, SUPERSTRUCTURE, DECK HOUSES, MACHINERY CASINGS, COMPANION WAYS AND ANY OTHER STRUCTURE AND EQUIPMENT SHOULD BE SUFFICIENT TO WITHSTAND ALL FORESEEABLE CONDITIONS OF THE INTENDED SERVICE. PSCO OBSERVED THE PORT AND STARBOARD WATER TIGHT DOORS WERE MISALIGNED, CLOSING WITHOUT SCRAPING THE PAINT OFF THE SURROUNDING AREA. CCSSC 2.4.1 50C
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2026
Resolved 6 May 2026
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 4 November 2025 Resolved
Fixed fire detection and alarm systems required by this chapter should comply with the regulations of the 1974 SOLAS convention. Fixed fire detection panel on the bridge presents a fault possibly rendering machinery space call points. Smoke and heat detector inoperable. Detectors did not alarm when tested.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2025
Resolved 6 November 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 November 2025 Resolved
Fire extinguishing systems should comply with the regulations of 1974 SOLAS convention. PSCO observed 05 engine room door and hatches unable to fully close.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2025
Resolved 5 November 2025
Resolution: Vessel adjusted all the dogs on the doors to achieve a complete seal.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 4 November 2025 Resolved
The total capacity of liferafts available shall be sufficient to accomodate the total number of persons onboard. Vessel did not have liferafts onboard.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2025
Resolved 6 November 2025
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 November 2025 Resolved
All machinery installations, mechanical equipment, and appliances should be of a design and construction adequate for the service for which they are intended and should be so installed and protected as to reduce to a minimum and danger to persons onboard.,due regard being paid to hot surfacese and other hazards. PSCO observed significant leak and accumulation of fuel oil from winch motor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2025
Resolved 6 November 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 November 2025 Resolved
ALL ELECTRICAL INSTALLATIONS, AND ELECTRICAL EQUIPMENT AND APPLIANCES SHOULD BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHOULD BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO HOT SURFACES AND OTHER HAZARDS. PSCO OBSERVED EXPOSED ELECTRICAL WIRING ON THE GENERATOR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2025
Resolved 6 November 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 4 November 2025 Resolved
HANDRAILS OF SUFFICIENT SIZE AND STRENGTH SHOULD BE PROVIDED WHERE NECESSARY IN THE OPINION OF THE ADMINISTRATION FOR PERSONS TO HOLD ON WHEN THE SHIP IS SEVERELY ROLLING OR PITCHING. PSCO OBSERVED EXCESSIVELY WASTED HANDRAIL ON THE AFT DECK.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2025
Resolved 6 November 2025
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 4 November 2025 Resolved
RESCUE BOATS SHOULD BE STOWED; IN A POSITION SUITABLE FOR LAUNCHING AND RECOVERY. PSCO OBSERVED OBSTRUCTIONS IN ROUTE TO RESCUE BOAT.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 November 2025
Resolved 6 November 2025
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 4 November 2025 Resolved
THE STRENGTH AND CONSTRUCTION OF HULL, SUPERSTRUCTURE, DECK HOUSES, MACHINERY CASINGS, COMPANION WAYS AND ANY OTHER STRUCTURE AND EQUIPMENT SHOULD BE SUFFICIENT TO WITHSTAND ALL FORESEEABLE CONDITIONS OF THE INTENDED SERVICE. PSCO OBSERVED THE PORT AND STARBOARD WEATHER TIGHT DOORS UNABLE TO FULLY CLOSE.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 November 2025
Resolved 6 November 2025
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 4 November 2025 Resolved
LIFEBUOYS SHOULD BE MARKED IN BLOCK CAPITALS OF THE ROMAN ALPHABET WITH THE NAME AND PORT OF REGISTRY OF THE SHIP ON WHICH IT IS CARRIED. PSCO OBSERVED FADED LETTERING ON STARBOARD BRIDGEWING LIFEBUOY.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2025
Resolved 6 November 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 November 2024 Resolved
At least half of the number of lifebuoys referred to in 4.12.1 should be fitted with self igniting lights which in takers should be of an electric battery type. PSCO observed 01 ight on port side and 01 light on starboard side bridge deck are inoperable. CCSSC Chap. 4.12.2 15AC
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 20 December 2024
Resolved 24 November 2024
Resolution: Vessel texted photos and videos of all lights attached to life buoys replaced with new. Video shows strobes functioning as designed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 November 2024 Resolved
All acccess openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or other equivalent material, permanently and strongly attached to the bulkhead, and framed, stifened and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead and weathertight when closed. PSCO observed significant wasting to steel frame of doors on paint lockerr and CO2 room which prevents weathertight seal. ICLL 66 Annex I/12-20 16AC
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2024
Resolved 4 December 2024
Resolution: Vessel sent in photos of welded repaired knife edges on doorways. See documents tab for more details.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 April 2024 Resolved
07199 - Fire Safety - All machinery and electrical installations, mechanical and electrical equipment and appliances, boilers and other pressure vessels, associated piping systems, fittings and electrical cables and wiring should be of a design and construction adequate for the service for which they are intended and should be so installed and protected as to reduce to a minimum any danger to persons onboard, due regard being paid to moving parts, hot surfaces and other hazards. PSCO observed the starboard main engine is inoperable and there is an active oil leak on one of the service generators. CCSSC (1997) 2.3
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2024
Resolved 14 April 2024
Resolution: Received class report clearing deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 8 April 2024 Resolved
11104 - Life Saving Appliances - Rescue boats should be stowed in a state of continuous readiness for launching in not more than five minutes. Crew was unable to start rescue boat engine. CCSSC (1997) 4.9.8.1
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2024
Resolved 8 April 2024
Resolution: Crew members were able to start the engine before PSCOs departed the vessel.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 12 October 2022 Resolved
The owner or master of every ship to which this code applies should ensure that after any survey of the ship under 1.10 has been completed, no significant change ssould be made in the structural arrangements, machinery, equipment, and other itmes covered by the survey, without the permission of the Administration. The one and two service generator fuel supply line handles are broken off and the fuel hoses should be replaced with the correct hoses and fittings. The lagging on the port exhaust stack needs to be replaced. Oil filter bridge connection has a leak that needs to be addressed. CCSSC (97) Ch.1 Reg. 1.11.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 November 2022
Resolution: Vessel sent in the required documentation and proof of repairs.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 12 October 2022 Resolved
The position of the rudder, if power- operated, shall be indicated at the navigational bridge. Vessels emergency steering was off ten degrees on the bridge indicator. CCSSC (97) CH.2 Reg 2.38.8
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2022
Resolution: Vessel adjusted the rudder indicator to ensure that the bridge and aux steering were reading the same. [name withheld] and MST2 woods verified the operation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 March 2020 Resolved
Electrical installations shall be such that the safety of personnel and ship from electrical hazards is ensured. PSCO observed multiple electrical hazards. Dead end electrical wires observed in way of air compressor tank above machinery space stairs and in overhead of galley. Protective cover missing from overhead galley light. Fuse box mounted on outboard side of gen set #3 distribution panel in not properly sealed, box is open to environment. Right and bottom of box indicator light for G.S. fire pump xyz missing (open hole in electrical box).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2020
Resolved 21 April 2020
Resolution: Deficiency rectified.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 3 September 2019 Resolved
Except as provided in Paragraphs (b) and (C) of this section no person may cause a vessel to enter into or get underway on the navigable waters of the United States unless no more than 12 hours before entering or getting underway, the following has been tested. PSCO observed that no pre-arrival tests had been conducted or logged for the Port of Ponce, PR.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 September 2019
Resolved 8 September 2019
Resolution: Company provided copy of Deck Log detailing satisfactory completion of pre-arrival checks.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2019 Resolved
Electrical installations shall be such that the safety of personnel and ship from electrical hazards will be assured. PSCO observed multiple electrical hazards throughout the ship to include; exposed electrical fixtures in crew cabin, unapproved 220v junction box STBD side engine room, exposed circuit breaker on side of main switch board in engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2019
Resolved 8 September 2019
Resolution: Electrical cables and components removed or repaired and found in satisfactory condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 3 September 2019 Resolved
The means for securing and maintaining weather tightness shall be to the satisfaction of the administration. The arrangements shall ensure that the tightness can be maintained in any sea condition. PSCO observed wasted gasket on FWD hatch, compromising weather tight integrity.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2019
Resolved 8 September 2019
Resolution: Wasted gasket on fwd hatch replaced with new and found in watertight condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 3 September 2019 Resolved
The rings, lines and letters shall be painted in white or yellow on a dark background. PSCO observed the white or yellow paint missing from the ring, lines and letters.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2019
Resolved 8 September 2019
Resolution: Plimsoll Load Line marks painted and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 September 2019 Resolved
Stairways and ladders shall be so arranged as to provide from machinery spaces and other spaces ready means to escape to open deck and then on to the survival craft. PSCO observed debris, rubbish and combustible liquids (in buckets) blocking access to the aft port emergency egress ladder.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 September 2019
Resolved 3 September 2019
Resolution: Debris, rubbish and combustible liquids removed from emergency egress ladder.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 September 2019 Resolved
Liquids that give off dangerous vapors and flammable gasses or other dangerous gasses shall be stored in a well ventilated space or on deck and protected against sources of ignition. PSCO observed buckets of flammable liquid stored in the engine room.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 3 September 2019
Resolved 3 September 2019
Resolution: Liquids removed from improper location and stored appropriately
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 3 September 2019 Resolved
Instructions concerning the maintenance and operation of all the equipment and installations on board for fighting and containment of fire shall be readily available in an accessible position. PSCO observed fire control plan storage case on port side was seized closed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 September 2019
Resolved 3 September 2019
Resolution: Fire control plan storage case was maintenance and functioned appropriately
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 September 2019 Resolved
Fixed fire detection and fire alarm systems of an approved type shall be installed in all machinery spaces, in all stairways, corridors, and escape routes on new ships. PSCO observed reoccurring fault on fire detection panel making the system inoperable in designated zone 1 (galley).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2019
Resolved 11 September 2019
Resolution: Detection sensors calibrated to alarm at proper static temperature. New call point installed, fully tested and found free of any faults.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 23 February 2019 Resolved
The master shall ensure that the frequency of drills performance shall not exceed the following frequencies; Abandon ship monthly. Vessel is conducting abandon ship drills quarterly. Vessels last abandon ship drill was 27NOV18 - CCSSC 2015 REG 7.4.3.5 - 10C
Action required: 10 - Deficiency Rectified
Resolved 23 February 2019
Resolution: MSD ST [name withheld] witnessed a satisfactory abandon ship drill while onboard the vessel.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 23 February 2019 Resolved
Periodic inspections of EPIRB shall at intervals not exceed 12 months of being inspected. Vessels last EPRIB service was 29NOV2017 - CCSSC 2015 REG 5.4.1 - 16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2019
Resolved 6 March 2019
Resolution: MSD ST Thomas received 406 Mhz EPIRB annual test report from Bureau Veritas from 13DEC2018 in Ponce, PR. Deficiency cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 23 February 2019 Resolved
Life saving appliances required by this chapter shall comply with technical specification of the LSA CODE. Launching appliances shall be arranged that the fully equipped rescue boat can safely launch against unfavorable conditions. Rescue boat does not have quick release mechanism installed to the davit - CCSSC 2015 REG 4.3.1 / LSA CODE 6.1.1.1 - 10C
Action required: 10 - Deficiency Rectified
Resolved 23 February 2019
Resolution: Vessel installed quick release mechanism onboard during PSC exam.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 23 February 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2019
Resolved 6 March 2019
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 February 2019 Resolved
An emergency fire pump shall be independently driven self contained pump in an accessible position outside the engine room and permanently connected to the fire mains. The use of portable fire pumps shall be avoided. Vessels emergency fire pump is portable and not connected to the fire main. CCSSC 2015 REG 3.3.10.1 - 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2019
Resolved 7 June 2019
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 23 February 2019 Resolved
Sanitary accommodations shall comply with the following requirements: hot fresh water available in all wash rooms. Vessel is not provided with hot water for all wash spaces. ILO-147/PWSA - 33 USC 1223(B)1 - 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2019
Resolved 7 June 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 August 2018 Resolved
In every ship, there shall be provided for the protection of any space containing internal combustion type machinery having a total power output of 750kw and above one of the fixed fire extinguishing systems referred to in 3.10.1. No fixed fire extinguishing system is installed. CCSSC 3.10.3.1 50a/c
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 7 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 August 2018 Resolved
Existing ships shall, as far as is reasonable and practicable in the opinion of the administration, comply with the provisions of this chapter and in existing ship that cannot maintain compliance with the provisions of this chapter shall not be assigned restricted area III and unrestricted by the administration. Vessel does not have the fixed fire detection system as required by 3.17.8. CCSSC 3.1.2 50a/c
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 7 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 August 2018 Resolved
The owner or master of every ship to which this code applies shall ensure that the condition of the ship and its equipment is maintained to conform with the provisions of this code to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship, persons on board or the environment. Main fire pump found to be leaking during operation. CCSSC 1.11.1 50a/c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 24 August 2018
Resolution: Repairs conducted on fire pump and operation test carried out - Satisfactory. No leaks were found at the fire pump. BV report of survey attached.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 August 2018 Resolved
Every life raft shall be stored with its painter permanently attached to the ship and with a float free arrangement so that the rafts float free. Life rafts found lashed to the ship keeping it from being able to float free. CCSSC 4.9.5 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 16 August 2018
Resolved 16 August 2018
Resolution: Lashing removed from life rafts allowing for the required float free arrangement.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 16 August 2018 Resolved
In all such ships, fire control plans shall be kept up to date. Fire control plan not up to date and missing information. CCSSC 3.13.2 50a/c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 7 June 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 August 2018 Resolved
Cooking appliances such as deep fat fryers or other types of appliances that could provide a high fire hazard in a seagoing environment shall not be fitted. Deep fat fryer found in galley. CCSSC 3.23.2 10c
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 16 August 2018
Resolved 16 August 2018
Resolution: Deep fat fryer removed from galley.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 16 August 2018 Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. Load line markings not painted white or yellow on a dark ground. ICLL Part1 Reg8 50b/c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 24 August 2018
Resolution: Load Line marks repainted in white color - satisfactory to the undersigned surveyor. BV report of survey attached.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 16 August 2018 Resolved
No person may operate any vessel equipped with an installed toilet facility unless it is equipped with an operable type II or III device that has a label on it under 159.16 or that is certified under 159.12 or 159.12a or an operable type I device that has a label on it under 159.16 or that is certified under 159.12. MSD does not have a required label or certification. 33 CFR 159.7 50 b/c
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 3 September 2018
Resolution: Certificate of Type Approval provided by owner. Test report CWNKM-0003-03 - Satisfactorily tested in accordance with provisions of MARPOL 73/78. Certificate added to activity.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 16 August 2018 Resolved
A chain locker should not be used for any purpose other than stowage of anchor chain cables. Chain lockers found full of water. CCSSC 2.6.2 50b/c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 24 August 2018
Resolution: Water in chain locker was pumped out to a shore tank in witness of the undersigned surveyor. BV report of survey attached.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 16 August 2018 Resolved
Electrical installations should be such that the safety of personnel and ship from electrical hazards will be assured. Electrical panel on bridge found with missing breaker and not blanked off. CCSSC 2.26.1.3 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 August 2018
Resolved 16 August 2018
Resolution: Missing breaker space properly blanked off removing electrical hazard from panel.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 1 May 2017 Resolved
Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 5 minutes. The 440 pound rescue boat is currently stowed 10 ft above the deck. The crew is unable to safely launch the rescue boat in it's current stowage condition. CCSSC (2015) CH 4.4.3, CH 4.3.1 Action code; 40c
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 September 2018
Resolved 18 January 2019
Resolution: Davit and rescue boat satisfactorily installed. Class report uploaded to documents.
Lifesaving › Rescue Boat › Inflated Condition
Issued 1 May 2017 Resolved
Every ship to which this chapter appplies shall carry at least one rescue boat complying with the requirement for a resue boat. The forward area of the rescue boat is punctured and deflated. CCSSC (2015) CH4.4.3 Action code; 17.a.c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2017
Resolved 4 May 2017
Resolution: Vessel now has onboard a rescue boat that meets requirements.
Fire Fighting › Fire Pumps › Location
Issued 1 May 2017 Resolved
The main and emergency fire pumps required fot the provision of water are required to have their sources of power and their controls installed outside the space protected by such systems. The fire pumps did not have controls or sources of power to be capable of starting from outside the space. CCSSC (2015) CH 3.3.9 Action code; 50 b,c
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 31 May 2017
Resolution: Control box to start/stop fire pump was installed outside the machinery space(portside main deck) and tested.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 1 May 2017 Resolved
All vessels operating in unrestricted areas are to be provided with two line throwing apparatus which shall be stored in the navigation bridge. Only one line throwing apparatus was provided on the bridge. CCSSC (2015) CH 4.13 Action code; 17 c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2017
Resolved 4 May 2017
Resolution: The required number of line throwing apparatus is maintained on STORM.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 1 May 2017 Resolved
Every ship shall be provided with at least two anchors provided with a chain cable of adequate strenght and size to the satisfaction of the administration. Port and starboard anchor chains showed signs of significant wastage on several die lock chain links. CCSSC (2015) CH 2.9.1 Action code 50 bc
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 31 May 2017
Resolution: Anchor chains repaired to the satisfaction of attending CG inspector
Documentation › Certificates/Documents › Caribbean Cargo Ship Safety Code Cert. (CCSSC)
Issued 21 November 2016 Resolved
A minium of two inspections shall be carried out during any five year period. Vessel has not undergone dry dock hull exam since 04 December 2011. CCSSC 1.10.1.5
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 November 2016
Resolved 25 January 2017
Resolution: Drydock was completed in 2014 and January 2017.
Documentation › Certificates/Documents › Caribbean Cargo Ship Safety Code Cert. (CCSSC)
Issued 21 November 2016 Resolved
No certificate shall be extended for a period longer than one month. Vessel's CCSSC was extended from 16 AUG 2016 to 16 NOV 2016. CCSSC 1.13.5
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 November 2016
Resolved 25 January 2017
Resolution: New CCSSC issued.
Documentation › Certificates/Documents › Caribbean Cargo Ship Safety Code Cert. (CCSSC)
Issued 8 October 2016 Resolved
Vessel changed from GL class to BV class in september and no new CCSSC certificate was issue. RIO Ponce recieved a copy of CCSSC Cert via email. Orginal copy needs to verified.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 January 2017
Resolution: Original copy of CCSSC was reviewed on board
Lifesaving › Inflatable Liferafts › Float Free
Issued 6 April 2016 Resolved
LIFE RAFT SHALL BE STOWED WITH ITS PAINTER PERMANENTLY ATTACHED TO THE SHIP WITH A FLOAT FREE ARRANGEMENT SO THAT THE LIFE RAFT FLOATS FREE. PSCO DISCOVERED PORT AND STBD SIDE LIFE RAFTS WERE TIED TO THE SHIP WITH A LINE AND NOT ARRANGED FLOAT FREE. STBD LIFE RAFT HYDROSTATIC RELEASE WAS DISCONNECTED DUE TO A BROKEN RELEASE WIRE. CCSSC(15)4.9.5 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2016
Resolved 8 April 2016
Resolution: VESSEL REPLACED HYDROSTATIC RELEASE WIRES AND CONNECTIONS WITH NEW PARTS.
Personnel › Manning/Qualifications › Medical Fitness
Issued 6 April 2016 Resolved
CANDIDATES FOR CERTIFICATION SHALL PROVIDE SATISFACTORY PROOF THAT THEY MEET THE STDS OF MEDICAL FITNESS SPECIFIED. PSCE IDENTIFIED 02 CREW (COOK)(WELDER) DID NOT HAVE A CURRENT VALID MEDICAL CERTIFICATE FOR SERVICE ON BOARD. STCW1/2 13.3 17AC
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2016
Resolved 8 April 2016
Resolution: CREW MEMEBERS RECIEVED VALID MEDICAL CERTIFICATES.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 6 April 2016 Resolved
RESCUE BOATS SHALL BE STOWED IN A SATE OF CONTINUOUS READINESS FOR LAUNCHING IN NO MORE THAN 5 MINUTES. VESSEL WAS STOWED WITHOUT ENGINE AND TOOK MORE THAN 45 MINS TO MAKE READY. CCSSC(15) 4.9.8.1 17AC
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2016
Resolved 8 April 2016
Resolution: [name withheld] TO SEE VESSELS RESCUE BOAT WAS MADE TO OPPERATIONAL, CREW ATTACHED MOTOR TO RESCUE BOAT ITS SELF AND WAS CONDTUING DRILLS.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 6 April 2016 Resolved
AFTER ANY SURVEY THE HAS BEEN COMPLETED, NO SIGNIFICANT CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENT OR MACHINERY. VESSELS CCSS CERTIFICATE INDICATED A PORTABLE DIESEL FIRE PUMP. WHICH WAS NOT SERVICEABLE AND THE CREW REPLACED WITH A GASOLINE PUMP. CCSSC(15) 1.11.3 50AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 May 2016
Resolution: Vessel has fully operational portable diesel fire pump on board.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 6 April 2016 Resolved
AFTER AN ACCIDENT OCCURS TO THE SHIP OR A DEFECT IS DISCOVERED, WITHER OF WHICH AFFECTS THE SAFETY OF THE SHIP OR EFFICIENCY. A REQUEST SHALL BE MADE IMMEDIATELY TO THE ADMIN FOR ISSUING A SURVEY AS MAY BE REQUIRED. PSCE DISCOVERED A LARGE PATCH ON THE STBD MDE HEAT EXCHANGE JACKET WATER SUPPLY PIPING THAT HAD NOT BEEN REPORTED. CCSCC(15) 1.11.350AC
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 5 May 2016
Resolution: Jacket water supply piping replaced.
Navigation › Piloting/Steering › US Coast Pilot
Issued 6 April 2016 Resolved
NAUTICAL CHARTS AND PUBLICATIONS SUCH AS LIGHT LIST, NOTICE TO MARINERS, TIDE TABLES, AND OTHER NAUTICAL PUBLICATIONS SHALL BE ADEQUATE AND UP TO DATE. VESSEL DID NOT HAVE ANY CURRENT PUBLICATIONS ON BOARD THAT WERE CURRENT. VESSEL HAD REPORTING ASKING COMPANY FOR UPDATES JANUARY2016. MOST RECENT PUB WAS 2014.CCSCC(15) 6.3.2 50AC
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 8 April 2016
Resolution: VESSEL RECIEVED ALL NEW PUBLICATIONS AS REQUIRED BY SOLAS.
Navigation › Piloting/Steering › Marine Charts
Issued 30 September 2015 Resolved
Nautical charts necessary for the intended voyage shall be adequate and up to date. Nautical charts on board are not current or corrected. CCSSC 6.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2015
Resolution: All nautical charts on board have been currently corrected based on Notice to Mariners
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 30 September 2015 Resolved
While at sea the ship should be capable of transmiting and receiving maritime safety information. The NAVTEX is inoperable. CCSSC 5.1.4.6
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 October 2015
Resolution: Printer mechanism on NAVTEX was replaced by Master Marine Electronics. Printer and NAVTEX are now operable.
Lifesaving › Lifebuoys › Serviceable
Issued 30 September 2015 Resolved
At least 4 of the grab lines on the lifebuoys are severely deteriorated. CCSSC 1.11.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2015
Resolution: Grablines on lifebuoys were replaced.
Lifesaving › Rocket Parachute Flares › General
Issued 17 September 2014 Resolved
Ship should be provided with no less than 06 rocket parachute flares. 03 rocket parachute flares found expired. CCSSC/4.13
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2014
Resolved 17 September 2014
Resolution: Vessel procured 03 new rocket parachute flares and placed on bridge.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 10 January 2014 Resolved
Vessels Stb. side life-raft is missing due to inclement weather and port side life-raft is secured not allowing float free design. Technition will be coming on board to replace Stb. side life-raft and correctely secure port side life-raft.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2014
Resolution: Inspected and cleared both Port and Starboard life-rafts. Starboard life-raft was replaced and Portside life-raft was repaired.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 10 January 2014 Resolved
Vessels AIS is currentely inoperable. Technition will be attending vessel to fix AIS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2014
Resolution: Received tech report attesting to the repairs to vessels AIS.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 10 January 2014 Resolved
Vessels SCBA air bottles our all expired. Vessel will replace all bottles.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2014
Resolution: Inspected SCBA bottles and all bottles found to be serviced and refilled.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 29 June 2012 Resolved
0230 - All seafarers serving onboard are required to provide an application for an endorsement has been submitted to the administration. Every ship to which the CCSSC applies, should be sufficiently and efficiently manned from the point of view of safety of life at sea. Chief Mate did not have a valid endorsement and has not received proof that an application for endorsement was received.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2012
Resolution: Received document from flag confirming [name withheld] application was received.
Communications › Radio Communications › EPIRB
Issued 18 May 2011 Resolved
EPIRB test not working. Light did not flash. Replace or repair EPIRB prior to departure.
Action required: 705 - Other - as specified
Due 19 May 2011
Resolved 19 May 2011
Resolution: EPIRB replaced and registered with flag.
Engineering › Diesel Engine (auxiliary) › Block
Issued 1 February 2011 Resolved
The auxiliary generators oil filter housing was found in an inoperable condition.
Due 8 February 2011
Resolved 9 February 2011
Resolution: Witnessed proper operation of auxiliary generator.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 1 February 2011 Resolved
Lagging on STBD engine found missing on the lower flex section of the exhaust.
Due 8 February 2011
Resolved 9 February 2011
Resolution: PSCO observed repairs made to lagging. ALL SAT
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 24 October 2010 Resolved
Electrical installations should be such that the safety of personnel and ship from electrical hazards will be assured. Electrical switchboard that services 3 ship service diesel generators does not have non-conducting mating in front of it. Install mating to the satisfaction of attending Port State Control Officer. CCSS Code 2.26
Due 24 October 2010
Resolved 24 October 2010
Resolution: Corrected on the spot.
Electrical › Lighting (service) › Switch
Issued 24 October 2010 Resolved
All electrical equipment should be of a design and construction adequate for the service for which they are intended. Starting switches for both fire pumps are missing their on-switch indicator light. Repair or replace both on-switch indicator lights to the satisfaction of attending Port State Control Officer.
Action required: 705 - Other - as specified
Due 31 October 2010
Resolved 26 October 2010
Resolution: Received written attestation that both on-switch indicator lights were permanently repaired and test. The deficiency has been rectified.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Determination of Alcohol/Drug Use
Issued 15 July 2007 Resolved
Vessel grounded at the Molasses Pier, St. Croix, US Virgin Islands. Issued 01 requirement to submit proof of chemical testing for entire crew to RIO St. Croix no later than 1000 16 July 2007 and prior to departure.
Action required: 705 - Other - as specified
Due 16 July 2007
Resolved 16 July 2007
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 June 2007 Resolved
Provide current and valid Flag registration. Provisional Registration expired upon arrival at Ponce, PR. Rectify prior to operating in U. S. jurisdictional waters.
Action required: 705 - Other - as specified
Resolved 22 June 2007
Resolution: Rcvd Flag extension on current provisional registry. Valid thru 21Sep07.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.