Records from 2008 to 2023. Most recent: inspection, 10 April 2023.
Documentation record
Registered dimensions (L × B × D)154.0 ft × 42.0 ft × 10.0 ft
Registered tonnagegross 543 / net 543
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderC & C MARINE AND REPAIR LLC · BELLE CHASSE, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 May 2026 · expires 30 June 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it543 - Simplified, Gross Ton
543 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
10 April 2023
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7665922
12 December 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7607726
13 October 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7076337
5 December 2019
Drydock Exam · MTSA Verification · Cargo Tank Internal · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6851209
17 April 2019
Administrative Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6664383
20 March 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6375461
28 November 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6322513
2 May 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6175890
19 April 2016
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5857334
2 February 2015
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5067529
18 August 2014
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4958925
10 February 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4795907
28 February 2012
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4249529
4 January 2011
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3920199
12 January 2010
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3662584
27 January 2009
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3401030
12 January 2009
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3402102
11 January 2009
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3392686
4 January 2008
Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · Hull Examination · Construction Oversight · COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3124210
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 2 May 2017
Resolved
Install correct connection on ECM box on pump engine to reroute wire harness and allow to reinstall water proof cover on box
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2017
Resolution: Third party installed proper connection to make pump water tight
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 4 January 2008
Resolved
Install alternator on cargo pump engine that is approved for Class 1, Div 1 locations IAW 46 CFR 111.105.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 January 2008
Deck/Cargo › Vapor Control Systems › Vapor Recovery Unit
Issued 4 January 2008
Resolved
Prior to operating Vapor Control System, provide approved plans.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 January 2008
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 4 January 2008
Resolved
Provide documentation that cargo pump engine wire harness and sensors are approved for Class 1, Div 1 locations IAW 46 CFR 111.105.
Due 30 June 2011
Resolved 7 February 2013
Resolution: The cargo pump engine was moved outside of the Class 1, Div 1 location.