MISS BELTERRA

MISS BELTERRA is a 2000 unclassified. The Coast Guard has recorded 92 inspections since 2000, most recently in February 2010, along with 139 deficiencies and 2 casualty investigations between 2000 and 2005.

Records from 2000 to 2010. Most recent: inspection, 5 February 2010.

Built
2000
Last inspected
5 February 2010
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA5824
Flag
UNITED STATES
366824210 (licence lapsed)
Maury page id
psix-8939

Inspections, by type

…with no type recorded23
Years with a record 11 calendar years (2000–2010)
The 92 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)313.9 ft × 93.0 ft × 16.0 ft
Registered tonnagegross 3,281 / net 2,603
ITC dimensions (L × B × D)313.9 ft × 93.0 ft × 16.0 ft
ITC tonnagegross 11,849 / net 3,672
BuilderALABAMA SHIPYARD INC · MOBILE, AL, UNITED STATES · built 2000
Hull materialSteel
PropulsionDiesel Outdrive
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portVEVAY, IN
Trade endorsementsRegistry
DocumentationValid · issued 3 April 2026 · expires 30 April 2027
Service, as the file records itUnclassified
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3281 - Regulatory (Subpart C or D), Gross Ton
11849 - Convention (Subpart B), Gross Ton
2603 - Regulatory (Subpart C or D), Net Ton
3672 - Convention (Subpart B), Net Ton
4295 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDA5824MMSI 366824210 · expired · compulsorily equipped · granted 28 August 2001, cancelled 29 October 2011
WCZ9148MMSI not assigned · expired · compulsorily equipped · granted 29 June 2000, cancelled 4 September 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

H.E. BOWLES Towing Vessel · MISLE 144151 · 4 June 2005 · activity 2383522ELIZABETH ANN Towing Vessel · MISLE 75038 · 31 July 2000 · activity 128827RCC 200 Freight Barge · MISLE 344259 · 31 July 2000 · activity 128827

Inspection history · 92

5 February 2010 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3675861
30 December 2009 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3656650
21 July 2009 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3500885
2 April 2009 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3447322
14 January 2009 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3561350
28 October 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3352841
2 October 2008 COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3335387
14 July 2008 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3267588
10 July 2008 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3264588
11 June 2008 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3233739
28 May 2008 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3220557
24 April 2008 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3192071
11 January 2008 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3128850
3 October 2007 COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3070578
27 September 2007 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3071265
12 July 2007 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2997259
25 April 2007 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2889159
26 March 2007 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2896580
11 January 2007 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2853997
10 October 2006 MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2811589
3 October 2006 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2794398
14 July 2006 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2711782
4 April 2006 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2616147
4 January 2006 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2559780
7 November 2005 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2529975
11 October 2005 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2512030
5 October 2005 MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2508113
5 October 2005 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2509694
25 August 2005 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2473192
12 August 2005 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2464611
25 July 2005 Hull Examination · Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2405424
6 July 2005 Deadweight Survey
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2405365
4 June 2005 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2383522
11 April 2005 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2329578
1 March 2005 Administrative Inspection · Deadweight Survey
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2317918
21 January 2005 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2268084
6 October 2004 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2214625
11 August 2004 MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2162278
13 July 2004 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2140363
7 July 2004 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2123767
7 April 2004 Quarterly Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2038224
7 April 2004 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2039994
28 January 2004 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1995430
12 January 2004 Quarterly Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1982363
6 November 2003 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1982423
6 October 2003 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1920489
30 July 2003 Quarterly Examination · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1840730
11 July 2003 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1855786
22 May 2003 Quarterly Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1802530
7 October 2002 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1693933
27 August 2002 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1667261
7 August 2002 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1660061
18 June 2002 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1635395
8 May 2002 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1616243
5 February 2002 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1484420
11 December 2001 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 773015
15 November 2001 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1410700
7 November 2001 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1075827
5 November 2001 Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1075831
17 October 2001 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1415697
18 September 2001 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1072954
11 September 2001 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1443256
6 September 2001 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 58069
9 August 2001 Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1074611
9 August 2001 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1483623
5 August 2001 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 180561
12 July 2001 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1069179
6 July 2001 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1453929
27 June 2001 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1431076
11 May 2001 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1432503
10 May 2001 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1064821
9 May 2001 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 75448
8 May 2001 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 45442
2 May 2001 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1472471
6 April 2001 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1063233
19 March 2001 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1062391
15 February 2001 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1060368
10 February 2001 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1410498
8 February 2001 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1062870
26 January 2001 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1413872
19 January 2001 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 174149
17 January 2001 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1444478
13 January 2001 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1431093
8 January 2001 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5314
22 October 2000 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1450556
16 October 2000 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1055198
6 October 2000 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 533080
5 October 2000 Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1055197
25 September 2000 COI Inspection · Damage Survey · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1365924
7 August 2000 Permit to Proceed
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1452703
31 July 2000 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 128827
23 July 2000 Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1426462

Deficiency record · 139

Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 October 2008 Resolved
Lifebuoy with light attached on stern not working
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 October 2008
Resolved 2 October 2008
Resolution: Repaired on site.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 2 October 2008 Resolved
STBD Poker Room Fire Screen door would not close.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 October 2008
Resolved 3 October 2008
Resolution: Repaired prior to departure.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 July 2008 Resolved
Emergency lighting fixture on 3rd deck between PFD box 11 and 12 has a fractured base and needs replaced.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 August 2008
Resolved 14 July 2008
Fire Fighting › Fire Hoses › Location
Issued 10 July 2008 Resolved
Fire hose cabinet door needs repaired on fire station 27 and 37
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 August 2008
Resolved 14 July 2008
Electrical › Electric Supply System (service) › Battery Charger
Issued 24 April 2008 Resolved
Make necessary repairs to DC1 and [name withheld].
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2008
Resolved 5 May 2008
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 24 April 2008 Resolved
Air Damper AHU #12 not labeled and not working properly, make necessary repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2008
Resolved 5 May 2008
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 24 April 2008 Resolved
2nd deck Firescreen door port fwd. Top latch not working, stbd aft door top latch needs tightened.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2008
Resolved 5 May 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure Gauge
Issued 11 January 2008 Resolved
Fire Extinguisher pressure gauge showed no pressure
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 January 2008
Resolved 11 January 2008
Construction/Loadline › Structures › Door
Issued 11 January 2008 Resolved
Operating alarm on #2 WTD did not operate
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 24 April 2008
Resolution: Operating alarm operational.
Fire Fighting › Fire Hydrants › Material
Issued 3 October 2007 Resolved
Make all fire stations and hoses on vessel IAW 46 CFR 76.10-10. Various stations throughout the ship do not have 2 1/2" connections and hoses IAW regulations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 3 October 2007
Fire Fighting › Ventilation Systems › Operating Controls
Issued 3 October 2007 Resolved
Repair outside air damper first deck AHU # 20. Damper has broken actuation arm.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 November 2007
Resolved 11 January 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 3 October 2007 Resolved
Repair third deck starboard aft stairwell entrance deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2008
Resolved 11 January 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 April 2007 Resolved
Install and mount fire extinguisher for # 36 fire extinguisher.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 July 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 25 April 2007 Resolved
Remove second # 37 fire extinguisher from electrical room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 July 2007
Fire Fighting › Fire Hydrants › Number
Issued 25 April 2007 Resolved
Correct fire hydrant numbers for # 32 and # 33, numbers should match numbers on fire control plan.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 July 2007
Fire Fighting › Ventilation Systems › Fans
Issued 25 April 2007 Resolved
Install missing indicator for soft count exhaust louvers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 July 2007
Fire Fighting › Ventilation Systems › Operating Controls
Issued 25 April 2007 Resolved
Install labels on fire dampers # 1 through 6 on the main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 July 2007
Fire Fighting › Ventilation Systems › Operating Controls
Issued 25 April 2007 Resolved
Properly label air handler unit dampers # 4 and # 8 on second deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 July 2007
Lifesaving › Lifebuoys › Size
Issued 11 January 2007 Resolved
Replace two (2) twenty-four (24) inch lifebuoys with thirty (30) inch lifebuoys as required by 46 CFR 199.70 which must meet 160.150.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 February 2007
Resolved 23 April 2007
Resolution: Two 30 inch lifebuoys were purchased and the 24 inch lifebuoys were replaced with the 30 inch lifebuoys.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 11 January 2007 Resolved
Prove proper operation of Main deck exhaust fan #9 and 2nd deck exhaust fan #12.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2007
Resolved 23 April 2007
Resolution: Exhaust fans # 9 and 12 are operating properly.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 11 January 2007 Resolved
Remove garbage from under counter in employee break room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 January 2007
Resolved 23 April 2007
Resolution: All trash removed from employee break room.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 3 October 2006 Resolved
Replace all three main engine high jacket water shut down sensors.
Action required: 705 - Other - as specified
Due 17 October 2006
Resolved 17 October 2006
Resolution: Sensors replaced and tested satisfactory.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 3 October 2006 Resolved
Repair or replace and prove proper operation of port rescue boat.
Action required: 705 - Other - as specified
Due 17 October 2006
Resolved 17 October 2006
Resolution: Port rescue boat engine repaired and tested satisfactory.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 11 April 2006 Resolved
33U.S.C.1321(j)(5)(G)-The vessel owner/operator has not provided certification ensuring that response resources are capable of responding to the maximum extent practicable, to a worst case discharge. 33U.S.C.1321(j)(5)(D)(i)-The NTVRP doesn't identify the vessel's intended areas of operation/COTP zones. It doesn't include the volume and type of oil that would be involved in a worst case discharge
Due 11 May 2006
Resolved 10 August 2009
Resolution: Response resources are capable of responding.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 11 April 2006 Resolved
33U.S.C.1321(j)(5)(D)(ii)-The NTVRP does not identify a qualified individual, provide 24-hour contract information for the qualified individual, or indicate that the qualified individual will have immediate contact with the NRC and the oil spill removal organization. 33U.S.C.1321(j)(5)(D)(iv)-The NTVRP does not address training as well as all applicable drill/exercise frequencies.
Due 11 May 2006
Resolved 10 August 2009
Resolution: Provided 24-hour contract information for the QI.
Accommodation/Occupational Safety › Ventilation › General
Issued 4 April 2006 Resolved
Fire damper 17 needs to be adjusted to close completely.
Condition: Improper/Lack of Maintenance
Due 11 April 2006
Resolved 4 April 2006
Resolution: Damper adjusted prior to completion of inspection.
Accommodation/Occupational Safety › Ventilation › General
Issued 4 April 2006 Resolved
Fire damper 20 needs to be adjusted to close completely.
Condition: Improper/Lack of Maintenance
Due 11 April 2006
Resolved 4 April 2006
Resolution: Damper adjusted prior to completion of inspection.
Accommodation/Occupational Safety › Ventilation › General
Issued 4 April 2006 Resolved
Fire damper 28 missing indicator.
Condition: Improper Installation
Due 11 April 2006
Resolved 4 April 2006
Resolution: Indicator installed prior to completion of inspection.
Accommodation/Occupational Safety › Ventilation › General
Issued 4 April 2006 Resolved
Duct work pulled away from fire damper 29.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2006
Resolved 14 July 2006
Resolution: Duct work reconnected to damper.
Accommodation/Occupational Safety › Ventilation › General
Issued 4 April 2006 Resolved
Air handler unit 4 needs to be adjusted to close completely.
Condition: Improper/Lack of Maintenance
Due 18 April 2006
Resolved 14 July 2006
Resolution: Unit adjusted and tested satisfactory.
Accommodation/Occupational Safety › Ventilation › General
Issued 4 April 2006 Resolved
Fire damper 8 is operable due to motor failure, three new motors are on order.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 14 July 2006
Resolution: Motor replaced and tested satisfactory.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 4 January 2006 Resolved
Replace # 5 air handler unit damper motor and prove proper operation of damper.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 February 2006
Resolved 14 July 2006
Resolution: Motor replaced and damper tested satisfactory.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 4 January 2006 Resolved
Replace # 7 air handler unit damper motor and prove proper operation.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 February 2006
Resolved 14 July 2006
Resolution: Motor replaced and damper tested satisfactory.
Engineering › Bilge Water Management System › Pump
Issued 4 January 2006 Resolved
Replace engine room bilge sump pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 February 2006
Resolved 14 July 2006
Resolution: Sump pump replaced.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 5 October 2005 Resolved
Prove proper operation of # 3 main engine high jacket water alarm.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 4 January 2006
Resolution: Alarm sensor replaced, tested satisfactory.
Engineering › Electric Propulsion System › Indicator Circuitry
Issued 5 October 2005 Resolved
Prove proper operation of # 1 main engine high lube oil temperature alarm.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 4 January 2006
Resolution: Alarm adjusted and tested satisfactory.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 5 October 2005 Resolved
Prove proper operation of # 1 main engine low lube oil pressure alarm.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 4 January 2006
Resolution: Alarm adjusted and tested satisfactory.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 5 October 2005 Resolved
Prove proper operation of # 1 main engine low lube oil shutdown.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 4 January 2006
Resolution: Alarm sensor adjusted and tested satisfactory.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 5 October 2005 Resolved
Prove proper operation of # 2 main engine low lube oil shut down.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 4 January 2006
Resolution: Alarm sensor adjusted and tested satisfactory.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 5 October 2005 Resolved
Prove proper operation of # 1 ships service generator high jacket water temperature alarm.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 4 January 2006
Resolution: Alarm sensor replaced and tested satisfactory.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 5 October 2005 Resolved
Prove proper operation of # 3 ships service generator high jacket water temperature alarm.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 4 January 2006
Resolution: Alarm sensor replaced and tested satisfactory.
Engineering › Electric Propulsion System › Indicator Circuitry
Issued 5 October 2005 Resolved
Prove proper operation of # 2 ships service generator high lube oil temperature alarm.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 4 January 2006
Resolution: Alarm sensor adjusted and tested satisfactory.
Engineering › Electric Propulsion System › Indicator Circuitry
Issued 5 October 2005 Resolved
Prove proper operation of # 4 ships service generator high lube oil temperature alarm.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 4 January 2006
Resolution: Alarm sensor adjusted and tested satisfactory.
Fire Fighting › Fire Hoses › Condition
Issued 5 October 2005 Resolved
Replace puntured 2.5 inch fire hose # 37.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2005
Resolved 5 October 2005
Resolution: Fire hose # 37 replaced with spare hose during the course of the inspection.
Communications › Alarms/Indicators › Fire Alarm
Issued 5 October 2005 Resolved
Install smoke detectors L 2 D 03, 04, 24 in proper address for detection system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 October 2005
Resolved 5 October 2005
Resolution: Smoke detectors installed in proper location in accordance with detection system.
Electrical › Electric Supply System (service) › Cable
Issued 25 July 2005 Resolved
Re-install proper bulkhead penetrations in #3 starboard void forward and aft bulkheads.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 4 August 2005
Resolution: Penetration blocks re-installed.
Electrical › Electric Supply System (service) › Cable
Issued 25 July 2005 Resolved
Remove loose wiring in #3 starboard void.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 4 August 2005
Resolution: Loose wires removed.
Stability › Watertight Integrity › General
Issued 25 July 2005 Resolved
Remove screws penetrating through overhead and make permanent repairs to holes in #4 port ballast tank.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 23 August 2005
Resolution: Screws were removed and repairs made.
Fire Fighting › Fire Hoses › Connections
Issued 25 July 2005 Resolved
Install missing pipe coupling for hose connection in fire station #25.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 12 August 2005
Resolution: Hose connection installed.
Fire Fighting › Fire Hydrants › Material
Issued 25 July 2005 Resolved
Repair or replace door for fire station #27.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 4 August 2005
Resolution: Door repaired.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 25 July 2005 Resolved
Clean and determine reason for fruit flies in aft second bar, take appropriate action to prevent future infestation. Install proper caps on liquor bottles in aft second deck bar.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2005
Resolved 12 August 2005
Resolution: Proper caps installed on liquor bottles.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 July 2005 Resolved
Remove all trash from around all equipment in stage bar.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 4 August 2005
Resolution: All trash removed.
Electrical › Electric Supply System (service) › Cable
Issued 25 July 2005 Resolved
Install missing wire for stern light over looked during poker room modification, prove proper operation of stern light.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 23 August 2005
Resolution: New wire was run to stern light and tested satisfactory.
Engineering › Generator (propulsion/auxiliary-electric) › Indicator Circuitry
Issued 25 July 2005 Resolved
Prove proper operation of #4 generator low voltage alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2005
Resolved 12 August 2005
Resolution: Low voltage alarm adjusted and tested satisfactory.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 25 July 2005 Resolved
Prove proper operation of fire dampers #7, #4, and AHU #1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2005
Resolved 12 August 2005
Resolution: Dampers adjusted and tested satisfactory.
Electrical › Electric Supply System (service) › Cable
Issued 11 April 2005 Resolved
Properly install wires in cableways provided in air handler units # 11, 15, 17.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 May 2005
Resolved 12 August 2005
Resolution: Wires properly installed in cableways.
Fire Fighting › Fire Hydrants › Condition
Issued 21 January 2005 Resolved
Remove folding table from in front of fire station in pump room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2005
Resolved 21 January 2005
Resolution: Table removed prior to completion of inspection.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 21 January 2005 Resolved
Remove gear adrift from tops of life jacket lockers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2005
Resolved 21 January 2005
Resolution: Gear removed prior to completion of inspection.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 7 July 2004 Resolved
Install pee trap in second deck bar deck drains to prevent sewage gasses from entering space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 August 2004
Resolved 11 August 2004
Resolution: Pee trap installed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 7 July 2004 Resolved
Remove gaming machines from escalator landing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 August 2004
Resolved 13 July 2004
Resolution: Received faxed documentation from [name withheld] stating the escalator landing area is a type 7 space and is part of the second deck casino. See attached documents.
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 7 April 2004 Resolved
Repair lube oil leak on number three generator turbocharger.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 May 2004
Resolved 7 July 2004
Resolution: Cummins technical representative repaired leak.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 7 April 2004 Resolved
Clean deck drains in bar spaces.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2004
Resolved 14 May 2004
Resolution: Drains cleaned.
Communications › Internal Communications System › Sound-powered Telephone
Issued 7 April 2004 Resolved
Properly mount phone jack in main deck port side bar.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2004
Resolved 14 May 2004
Resolution: Phone jack properly mounted.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 13 January 2004 Resolved
Repair/ replace and test faulty governor on number one ships service generator. LEGACY COMPONENT DESC: Governor
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 February 2004
Resolved 23 January 2004
Resolution: Cummins technical representative replaced governor and adjusted valves and injectors, tested engine at all speeds and loads, test satisfactory.
Electrical › Electrical Distribution System (service)
Issued 7 October 2003 Resolved
Install proper rox blocks for cable port side forward and aft bulkheads in pump room. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2003
Resolved 6 November 2003
Resolution: Proper rox blocks installed.
Electrical › Electrical Distribution System (service)
Issued 7 October 2003 Resolved
Install missing junction box cover aft bulkhead in pump room. LEGACY COMPONENT DESC: Junction Box
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2003
Resolved 6 November 2003
Resolution: Missing cover installed.
Electrical › Electrical Distribution System (service)
Issued 7 October 2003 Resolved
Properly dead end wires above switchboard VP100 and next to sprinkler hold deck control valve in pump room. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2003
Resolved 6 November 2003
Resolution: Wires properly dead ended or removed.
Fire Fighting › Automatic Sprinkler System
Issued 7 October 2003 Resolved
Properly identify sprinkler system test valves to match drawing and alarm panel indentifction. LEGACY COMPONENT DESC: Test Valves
Action required: 705 - Other - as specified
Due 7 November 2003
Resolved 6 November 2003
Resolution: Labels made and installed to match drawing and alarm panel.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 7 October 2003 Resolved
Clean all service area deck drains of trash, mold and mildew, Master shall perform monthy sanitary inspections in accordance with 46 CFR 71.45-1. LEGACY COMPONENT DESC: Recreation Space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2003
Resolved 6 November 2003
Resolution: Areas cleaned and Master makes weekly inspections.
Electrical › Electric Generation Source (emergency)
Issued 7 October 2003 Resolved
Prove proper operation of emergency generator alarm panels in pilot house and engine room control. LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2003
Resolved 6 November 2003
Resolution: Manufacturers technical representative on board performed required tests, all satisfactory.
Engineering › Diesel Engine (auxiliary)
Issued 30 July 2003 Resolved
Prove proper operation of all overspeed trips on all ships service generators. LEGACY COMPONENT DESC: Overspeed Device
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 October 2003
Resolved 4 August 2003
Resolution: Engine manufacturers representative tested all ships service generators by using a test switch inside engine control panel, all tests satisfactory.
Electrical › Electric Generation Source (service)
Issued 30 July 2003 Resolved
Prove proper operation of reverse power relays and indicator lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 October 2003
Resolved 4 August 2003
Resolution: All reverse power relays, alarms, and indicator lights tested satisfactory.
Electrical › Electric Generation Source (emergency)
Issued 30 July 2003 Resolved
Prove proper operation of emergency generator off and manual operation indicator lights (both lights stay on when in off position). LEGACY COMPONENT DESC: Power Requirement
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 October 2003
Resolved 6 November 2003
Resolution: Third party found and corrected inproper wiring for emergency generator. Tested all operations to CG inspector satisfaction.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 30 July 2003 Resolved
Provide U. S. Coast Guard approved machinery automation test procedures, and prove proper operation of all tests.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 October 2003
Resolved 4 August 2003
Resolution: Found CG approved procedures in local vessel file, made copies for vessel.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 30 July 2003 Resolved
Prove proper operation of number ships service generator cooling water temperature alarm.
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 4 August 2003
Resolution: Replaced and tested new sensor.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 22 May 2003 Resolved
Remove excess gear from forward pump room, should not be used as storage area.
Due 22 June 2003
Resolved 30 July 2003
Resolution: Excess gear removed and stowed properly.
Electrical › Electric Generation Source (service)
Issued 22 May 2003 Resolved
Inspect, repair/replacemeters and gauges on generator control panel. LEGACY COMPONENT DESC: Panelboard
Due 22 June 2003
Resolved 6 November 2003
Resolution: All gauges replaced.
Engineering › Diesel Engine (auxiliary)
Issued 22 May 2003 Resolved
Replace Murphy switches (jacket water low level alarm) on #2, 3, and 4 generator engines.
Due 22 June 2003
Resolved 6 November 2003
Resolution: All switches replaced.
Engineering › Diesel Engine (auxiliary)
Issued 22 May 2003 Resolved
Replace oil pressure gauges on #1, 3, and 4 generators.
Due 22 June 2003
Resolved 6 November 2003
Resolution: All gauges replaced.
Navigation › Collision/Grounding Avoidance
Issued 13 May 2002 Resolved
Prove proper operation of vessel depht finder (transducer). LEGACY COMPONENT DESC: Echo-sounding Device
Condition: Unknown
Due 8 June 2002
Resolved 13 May 2002
Fire Fighting › Miscellaneous Items
Issued 5 February 2002 Resolved
Check and verify locations and addresses of fire call/pull boxes.
Condition: Unknown
Due 12 February 2002
Resolved 6 February 2002
Resolution: Multicom communication technician checked and verified locations, proper working conditions of fire call/pull boxes, and fire panel.
Engineering
Issued 5 November 2001 Resolved
REPLACE/REPAIR PRIME MOVER FOR NUMBER ONE (1) SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 5 November 2001
Resolved 5 November 2001
Electrical
Issued 6 July 2001 Resolved
PROVIDE FMEA FOR APPROVAL, LOSS OF AUTO LOAD SHED WITH LOSS OF BOW THRUSTERTOTALIZER BOARD, OR CORRECT EXISTING CONDITION AND RETEST FMEA FOR LOSS OF TOTALIZER BOARD SHOWING AUTO LOAD SHED IS NOT LOST.
Condition: Unknown
Due 9 July 2001
Resolved 25 August 2001
Electrical
Issued 6 July 2001 Resolved
MAKE REQUIRED CHANGES TO THE GENERATOR CONTROLS TO CORRECT PROBLEMS RESULTING FROM 1 24V DC INPUT TO THE PLC, AND PROVE SATISFACTORY OPERATION OF SAME.
Condition: Unknown
Due 9 July 2001
Resolved 25 August 2001
Electrical
Issued 6 July 2001 Resolved
SUBMIT FMEA/PSTP FROMMFG, CON-SELECT, FOR GENERATOR GOVERNOR CONTROL CHANGES MADE FOR APPROVAL.
Condition: Unknown
Due 9 July 2001
Resolved 25 August 2001
Electrical
Issued 6 July 2001 Resolved
VESSEL SHALL REMAIN DOCKSIDE UNTIL DESIGN CHANGES TO THE GENERATOR GOVERNORCONTROLS ARE COMPLETED AND SATISFACTORY OPERATION IS PROVEN.
Condition: Unknown
Due 9 July 2001
Resolved 25 August 2001
Navigation
Issued 27 June 2001 Resolved
SUBMIT AMENDED FMEA TEST PROCEDURE FOR EPD INC BOW THRUSTER FAILURE #7, LOSS OF TOTALIZER BOARD, FOR APPROVAL.
Condition: Unknown
Due 4 July 2001
Resolved 20 August 2001
Electrical
Issued 27 June 2001 Resolved
PROVIDE EQUIPMENT AND PROCEDURES TO PROVE PROPER OPERATION OF ALL EMERGENCYGENERATOR SAFETIES AND ALARMS.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Electrical
Issued 27 June 2001 Resolved
SUBMIT FOR APPROVAL, CON-SELECT AMENDED FMEA TEST PROCEDURE SHOWING LOSS OFAUTO LOAD SHED, MANUAL LOAD SHED ONLY AVAILABLE, WITH BOW THRUSTER TOTALIZER BOARD FAILURE.
Condition: Unknown
Due 4 July 2001
Resolved 20 August 2001
Lifesaving
Issued 27 June 2001 Resolved
PROVE SATISFACTORY OPERATION OF THE REFRIGERANT ALARM LOCATED IN THE GENERATOR ROOM.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Navigation
Issued 11 May 2001 Resolved
MAKE REPAIRS TO BOW THRUSTER STEERING CONTROLS AND PROVE SATISFACTORY OPERATION OF BOTH BOW THRUSTERS. VESSEL SHALL REMAIN DOCKSIDE UNTIL CORRECTED.
Condition: Unknown
Due 10 June 2001
Resolved 14 May 2001
Fire Fighting
Issued 2 May 2001 Resolved
PROVIDE SAFE MEANS TO ACCESS ALL AIR HANDLER AND EXHAUST UNITS FOR PERFORMANCE OF MAINTENANCE AND INSPECTIONS.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Fire Fighting
Issued 2 May 2001 Resolved
PROVE SATISFACTORY OPERATION OF #6 AIR HANDLER UNIT FIRE DAMPNER.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Engineering
Issued 2 May 2001 Resolved
PROVE SATISFACTORY OPERATION OF THE EPD, DVTP AND FMEA FAILURE #7, BOW THRUSTER EQUALIZER BOARD FAILURE, AS SUBMITTED BY EPD, OR REWRITE AND PROVESATISFACTORY FAILURE MODE PER THE NEW TEST PROCEDURE/FMEA.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Electrical
Issued 2 May 2001 Resolved
PROVIDE EQUIPMENT AND PROCEDURES TO PROPERLY TEST THE EMERGENCY GENERATOR ALARMS AND SAFETIES, AND PROVE SATISFACTORY OPERATION OF ALL REQUIRED ALARMS AND SAFETIES.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Lifesaving
Issued 2 May 2001 Resolved
PROVIDE PROCEDURE FOR, AND PROVE SATISFACTORY OPERATION OF, THE REFRIGERANTALARM IN THE GENERATOR ROOM.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Fire Fighting
Issued 19 March 2001 Resolved
MAKE PERMANENT REPAIR TO SIGHT GLASS IN SPRINKLER SYSTEM FLOW INDICATOR FORTHE HOLD DECK LOOP. THE VESSEL MUST REMAIN DOCKSIDE WITH A 24 HOUR ROVING FIRE WATCH ON THE HOLD DECK UNTIL COMPLETED.
Condition: Unknown
Due 19 April 2001
Resolved 17 May 2001
Electrical
Issued 26 January 2001 Resolved
REMOVE OR PROPERLY TERMINATE DEAD ENDED WIRES UNDER PILOT HOUSE CHART TABLENEAR THE ROX BOX, STBD END OF CHART TABLE.
Condition: Unknown
Due 26 February 2001
Resolved 8 March 2001
Engineering
Issued 26 January 2001 Resolved
SUBMIT EPD FAILURE MODE EFFECT ANALYSIS AND DESIGN VERIFICATION TEST PROCEDURES, AS AMENDED, TO [name withheld].
Condition: Unknown
Due 26 February 2001
Resolved 8 March 2001
Fire Fighting
Issued 26 January 2001 Resolved
ADJUST EXHAUST UNITS 3, 4, AND 21 FIRE DAMPNERS, ON MAIN DECK, TO CLOSE COMPLETELY.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Accommodation/Occupational Safety
Issued 26 January 2001 Resolved
INSTALL DECK DRAIN COVERS, HOLD DECK.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Electrical
Issued 26 January 2001 Resolved
SUBMIT CON-SELECT FAILURE MODE EFFECT ANALYSIS, DESIGN VERIFICATION, AND PERIODIC SAFETY TEST PROCEDURES, AS AMENDED, TO [name withheld].
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Lifesaving
Issued 26 January 2001 Resolved
CHANGE COLOR OF FREON ALARM BEACON IN THE GENERATOR ROOM SO AS TO NOT CONFUSE IT WITH THE GENERAL ALARM, AND DEVELOPE TEST PROCEDURE FOR INCLUSION IN PSTP TO DEMONSTRATE PROPER OPERATION. INSTALL SUITABLE WARNING PLACARDS AT THE ALARM LOCATION.
Condition: Unknown
Due 26 February 2001
Resolved 8 March 2001
Electrical
Issued 26 January 2001 Resolved
INSTALL GROUND FAULT DETECTION ON THE SECONDARY SIDE OF BOTH GAMING TRANSFORMERS.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Documentation
Issued 26 January 2001 Resolved
SUBMIT SPREADSHEET FOR ALL WEIGHT CHANGES MADE TO THE VESSEL AFTER THE LASTDEADWEIGHT SURVEY TO [name withheld].
Condition: Unknown
Due 26 February 2001
Resolved 8 March 2001
Fire Fighting
Issued 26 January 2001 Resolved
PROVIDE ACCESS TO AIR HANDLER UNITS (AHU) 13,14,AND 21 ON MAIN DECK TO INSPECT FIRE DAMPNER OPERATION.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Engineering
Issued 26 January 2001 Resolved
INSTALL BOW THRUSTER RESET IN PILOT HOUSE.
Condition: Unknown
Due 26 February 2001
Resolved 8 March 2001
Documentation
Issued 26 January 2001 Resolved
PENDING APPROVAL OF VESSEL'S SAFETY ASSESSMENT PROPOSAL UNDER 46CFR199.630(f) BY [name withheld], THE VESSEL'S OPERATING AREA IS RESTRICTED TO IT'S SLIP/SLUE AREA UP TO, BUT NOT INCLUDING, THE OHIO RIVER.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Lifesaving
Issued 26 January 2001 Resolved
REMOVE COMBUSTIBLE MATERIALS THAT ARE PRESENTLY STORED IN THE BATTERY ROOM ON THE HOLD DECK STBD SIDE.
Condition: Unknown
Due 26 February 2001
Resolved 8 March 2001
Electrical
Issued 26 January 2001 Resolved
REPLACE BURNED OUT EMERGENCY LIGHT ON 2ND DECK, OUTBOARD LIGHT BY STBD FORWARD EXTERIOR DOORS.
Condition: Unknown
Due 26 February 2001
Resolved 8 March 2001
Accommodation/Occupational Safety
Issued 26 January 2001 Resolved
INSTALL AND PROVE SATISFACTORY OPERATION OF SEWAGE TANK LEVEL INDICATORS/ALARMS.
Condition: Unknown
Due 26 February 2001
Resolved 8 March 2001
Fire Fighting
Issued 26 January 2001 Resolved
RECORD SOUND LEVEL ON GAMING DECKS, IN LOCATIONS NOTED ON THE BASE DIAGRAM PROVIDED BY MULTICOM INC FOR THE AEVADS SYSTEM, ON A FRIDAY OR SATURDAY NIGHT WHEN THE GAMING AREAS ARE THE BUSIEST. TEST SOUND LEVEL OF AEVADS.
Condition: Unknown
Due 26 February 2001
Resolved 8 March 2001
Engineering
Issued 17 January 2001 Resolved
INSTALL BOW THRUSTER REST IN PILOT HOUSE.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Navigation
Issued 17 January 2001 Resolved
REPAIR AND PROVE SATISFACTORY OPERATION OF THE STERN DEPTH SOUNDER TRANSDUCER.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Electrical
Issued 17 January 2001 Resolved
INSTALL GROUND FAULT DETECTION ON SECONDARY SIDE OF BOTH GAMING TRANSFORMERS.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Documentation
Issued 22 October 2000 Resolved
SUBMIT SPREADSHEET FOR ALL WEIGHT CHANGES MADE ON THE VESSEL AFTER THE LASTDEADWEIGHT SURVEY, TO [name withheld].
Condition: Unknown
Due 22 October 2000
Resolved 22 October 2000
Fire Fighting
Issued 22 October 2000 Resolved
THE TEMORARY CLOSURES PRESENTLY INSTALLED FOR THE STARBOARD ELEVATOR, MAIN DECK AND HOLD DECK, SHALL NOT BE REMOVED OR ALTERED WITHOUT PRIOR APPROVAL OF [name withheld], EXCEPT IN A CASE DEEMED AN EMERGENCY BY THE VESSEL MASTER.
Condition: Unknown
Due 22 October 2000
Resolved 22 October 2000
Engineering
Issued 22 October 2000 Resolved
SUBMIT SCHOTTEL FAILURE MODE EFFECT ANALYSIS AND DESIGN VERIFICATION TEST PROCEDURE DOCUMENTS AS AMENDED BY THE SCHOTTEL TECH REP, FOR APPROVAL BY [name withheld].
Condition: Unknown
Due 1 December 2000
Resolved 1 December 2000
Fire Fighting
Issued 22 October 2000 Resolved
IF THE GENERATOR ROOM MAINDECK DOOR IS REMOVED, NO PASSENGERS MAY BE CARRIED UNTIL IT HAS BEEN REINSTALLED TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 22 November 2000
Resolved 1 December 2000
Lifesaving
Issued 22 October 2000 Resolved
PENDING APPROVAL OF VESSEL'S SAFETY ASSESSMENT PROPOSAL UNDER 46 CFR 199.630(f) BY [name withheld], THE VESSEL'S OPERATING AREA IS RESTRICTED TOIT'S SLUE/SLIP AREA UP TO, BUT NOT INCLUDING, THE OHIO RIVER.
Condition: Unknown
Due 22 October 2000
Resolved 22 October 2000
Engineering
Issued 22 October 2000 Resolved
SUBMIT EPD FAILURE MODE EFFECT ANALYSIS AND DESIGN VERIFICATION TEST PROCEDURE DOCUMENTS, AS AMENDED, TO [name withheld].
Condition: Unknown
Due 22 October 2000
Resolved 22 October 2000
Electrical
Issued 22 October 2000 Resolved
INSTALL AND PROVE SATISFACTORY OPERATION OF OF AN AUDIO/VISUAL ALARM IN THEEOS FOR SHIP SERVICE GENERATOR PLC FAILURE.
Condition: Unknown
Due 4 December 2000
Resolved 11 December 2000
Engineering
Issued 22 October 2000 Resolved
SUBMIT PERIODIC SAFETY TEST PROCEDURES, AS AMENDED, TO [name withheld].
Condition: Unknown
Due 22 October 2000
Resolved 22 October 2000
Lifesaving
Issued 22 October 2000 Resolved
SUBMIT EEP FOR APPROVAL BY [name withheld].
Condition: Unknown
Due 22 October 2000
Resolved 22 October 2000
Fire Fighting
Issued 22 October 2000 Resolved
SUBMIT REVISED FIRE CONTROL PLAN FOR APPROVAL BY [name withheld].
Condition: Unknown
Due 22 October 2000
Resolved 22 October 2000
Accommodation/Occupational Safety
Issued 22 October 2000 Resolved
CONDUCT TEST OF STARBOARD ELEVATOR IAW ANSI A17.1 AND 17.1A AS INCORPORATEDINTO 46 CFR 111.91-1. NO PERSONS MAY USE THE ELEVATOR UNTIL COMPLETED.
Condition: Unknown
Due 22 October 2000
Resolved 22 October 2000
Accommodation/Occupational Safety
Issued 22 October 2000 Resolved
CONDUCT TEST OF STARBOARD ELEVATOR, ASSOCIATED FIRE CONTROL PANEL/AEVADS SYSTEMS. NO PERSONS MAY USE THE ELEVATOR UNTIL COMPLETED.
Condition: Unknown
Due 22 October 2000
Resolved 22 October 2000
Lifesaving
Issued 22 October 2000 Resolved
CHANGE COLOR OF FREON ALARM BEACON IN THE GENERATOR ROOM SO AS TO NOT CONFUSE IT WITH THE GENERAL ALARM. DEVELOP TEST PROCEDURE FOR INCLUSION INTHE PSTP AND INSTALL SUITABLE PLACARDS AT THE ALARM LOCATION.
Condition: Unknown
Due 22 October 2000
Resolved 22 October 2000
Electrical
Issued 22 October 2000 Resolved
REPAIR/REPLACE #2 SSG AND COMPLETE ALL TESTS REQUIRED BY, AND IN ACCORDANCEWITH, AMENDED PERIODIC TEST PROCEDURES.
Condition: Unknown
Due 4 December 2000
Resolved 11 December 2000
Electrical
Issued 22 October 2000 Resolved
TEST PROPER OPERATION OF ALL SSG PLC CONTROLS, INCLUDING LOAD SHED, IN ACCORDANCE WITH CON-SELECT AMENDED DESIGN VERIFICATION AND PERIODIC SAFETY TEST PROCEDURES.
Condition: Unknown
Due 4 December 2000
Resolved 11 December 2000
Accommodation/Occupational Safety
Issued 25 September 2000 Resolved
RENEW PORT SEWAGE TANK LEVEL INDICATOR GAUGE IN EOS.
Condition: Unknown
Due 25 October 2000
Resolved 5 October 2000
Lifesaving
Issued 25 September 2000 Resolved
PROVIDE INFLATABLE BUOYANT APPARATUS TO ACCOMMODATE 67% OF THE TOTAL PERSONS ON BOARD IAW 46 CFR 199.630(g) OR SUBMIT FOR APPROVAL A SAFETY ASSESSMENT TO THE LOCAL [name withheld] 46 CFR 199.630(F).
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Electrical
Issued 25 September 2000 Resolved
REPAIR OR RENEW #2 SHIP'S SERVICE DIESEL GENERATOR AND CONDUCT TESTING IAW APPROVED CONTROL VERIFICATION AND PERIODIC TEST PROCEDURES TO THE SATISFACTION OF AN ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Fire Fighting
Issued 25 September 2000 Resolved
CHANGE COLOR OF FREON BEACON SO AS NOT TO CONFLICT WITH COLOR OF GENERAL ALARM BEACON IN THE ENGINE ROOM. POST INSTRUCTIONS FOR PROCEDURES TO BE TAKEN WHEN THE FREON BEACON IS ENERGIZED.
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Documentation
Issued 25 September 2000 Resolved
PROVIDE APPROVED CONTROL VERIFICATION AND PERIODIC TEST PROCEDURES IAW 46 CFR 61.40. CONDUCT TESTING IAW THE APPROVED PLANS UTILIZING THE VESSEL'S CREW AND WITNESSED TO THE SATISFACTION OF AN ATTENDING CG MARINE INSPECTOR.NO PASSENGERS AUTHORIZED UNTIL THIS ITEM CLEARED BY THE LOCAL OCMI.
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Accommodation/Occupational Safety
Issued 25 September 2000 Resolved
CONDUCT TEST OF STARBOARD ELEVATOR IAW ANSI/ASME A17.1 AND 17.1A AS INCORPORATED BY 46 CFR 111.91-1. USE OF THIS ELEVATOR NOT AUTHORIZED UNTILINSPECTED TO THE SATISFACTION OF AN ATTENDING CG MARINE INSPECTED.
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Documentation
Issued 25 September 2000 Resolved
RESUBMIT FIRE CONTROL PLAN TO INCORPORATE ALL PEN AND INK CHANGES TO THE LOCAL OCMI FOR APPROVAL.
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Accommodation/Occupational Safety
Issued 25 September 2000 Resolved
CONDUCT TEST OF THE STARBOARD ELEVATOR IN CONJUNCTION WITH ALL ASSOCIATES FIRE CONTROL PANEL/AEVADS COMPONENTS. NO ELEVATOR OPERATION PERMITTED WITHPASSENGERS UNTIL STATISFACTORY TESTING IS WITNESSED BY AN ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Fire Fighting
Issued 25 September 2000 Resolved
INSTALL NON-COMBUSTIBLE TABLE LEGS ON MAIN DECK GAMING TABLES DUE TO OVERAGE ON FIRE LOAD CALCULATIONS. NO PASSENGERS PERMITTED ON MAIN DECK UNTIL THIS ITEM IS CLEARED BY THE LOCAL OCMI.
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000

Casualty record · 2

31 July 2000Major Marine Casualty · role: Involved in a Marine Casualty · activity 128827
4 June 2005Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · at MARKLAND · activity 2383522
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.