Documentation record
Registered dimensions (L × B × D)384.0 ft × 130.0 ft × 25.0 ft
Registered tonnagegross 9,867 / net 2,960
ITC dimensions (L × B × D)384.0 ft × 130.0 ft × 25.0 ft
ITC tonnagegross 9,867 / net 2,960
BuilderGUNDERSON MARINE LLC · PORTLAND, OR, UNITED STATES · built 2007
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 12 May 2026 · expires 30 June 2027
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9867 - Convention (Subpart B), Gross Ton
23600 - Dead Weight, Gross Ton
2960 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 42 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 42
13 May 2026
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8375841
11 May 2026
Administrative Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8371008
12 August 2025
Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8207910
25 July 2025
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8194506
12 May 2025
Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8130875
11 December 2024
Deficiency Check · In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8046233
20 August 2024
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7985640
18 June 2024
MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7932865
2 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7802176
9 August 2023
MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7762418
13 September 2022
Examination of Repairs · MARPOL Annex I Examination · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7467272
28 June 2022
Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7489907
9 May 2022
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7440590
2 April 2022
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7444524
30 March 2022
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7421429
2 October 2021
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7325983
20 August 2021
Annual Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7292034
30 March 2021
Special
Type not classified · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7165703
29 March 2021
Special
Type not classified · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7167154
15 December 2020
Special · Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7113277
14 May 2020
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6953103
5 May 2020
Annual Inspection · MARPOL Annex I Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6946161
29 July 2019
MARPOL Annex I Examination · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6760639
21 June 2018
MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6444217
26 June 2017
MARPOL Annex I Examination · MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6187082
20 June 2017
Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6181227
28 April 2017
Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6134493
8 June 2016
MARPOL Annex I Examination · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5899462
3 February 2016
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5809241
2 November 2015
Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5753689
7 August 2015
Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5206463
6 May 2015
MARPOL Annex I Examination · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5117038
12 March 2015
Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5081364
3 April 2014
MTSA Verification · Periodic Inspection · MARPOL Annex I Examination · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4827549
29 August 2013
MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4698462
19 June 2012
MARPOL Annex I Examination · COI Inspection · Internal Structural Exam · Drydock Exam · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4348817
16 June 2011
MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4045879
10 June 2010
MARPOL Annex I Examination · Internal Structural Exam · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3787452
22 July 2009
Annual Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3542585
21 November 2008
MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3366268
8 May 2008
MARPOL Annex I Examination · Construction Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3206632
30 April 2007
Initial Certification · Construction Oversight
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3012426
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 December 2024
Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.112 securely attached to the front shoulder area of the lifejacket. 01 lifejacket onboard did not have a lifejacket light.
46 CFR 96.06-1
46 CFR 199.70(b)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2024
Resolution: Provided receipt and photo evidence of lifejacket light.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 December 2024
Resolved
Containers, brackets, racks, and other similar stowage locations for lifesaving equipment must be marked with symbols in accordance with IMO Resolution A.760(18) indicating the device stowed in that location. The liferaft stowage locations were not marked with the correct symbols.
46 CFR 96.06-1
46 CFR 199.178(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2024
Resolution: Provided receipt and photo evidance of liferaft stowage locations marking.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 December 2024
Resolved
Each lifejacket, immersion suit, and anti-exposure suit container must be marked in block capital letters and numbers with the quantity, identity, and size of the equipment stowed inside the container. The equipment may be identified in words or with the appropriate symbol from IMO Resolution A.760(18). The lifejacket and immersion suit containers were not marked with the quantity of the equipment stowed inside the container.
46 CFR 96.06-1
46 CFR 199.70(d)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2024
Resolution: Provided photo evidance that lifejacket and immersion suit containers were marked with the quantity of the equipment stowed inside the container.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 11 December 2024
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. As per USCG Type Approval number 160.162/3/3, the device is intended for disposal 2 years after installation; not subject to annual testing. The disposable hydrostatic release unit was marked with an expiration date greater than two years after the date on which the unit is installed.
46 CFR 96.06-1
46 CFR 199.190
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2024
Resolution: Provided receipt and photo evidence that new hydrostatic release units were purchased and installed with correct expiration date.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 9 May 2022
Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he deem necessary to be assured of the safety and seaworthiness of the vessel. All void entrance ladders are corroded and pose a safety risk for anyone entering. Vessel must crop and renew during next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 September 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 October 2021
Resolved
The OCMI may issue a permit to proceed to another port for repair, if in thier judgement it can be done safely. An inspection either general or partial, depending on the circumstances, shall be made whenever any important repairs are undertaken.
[name withheld] and Morgan City agreed that the vessel may conduct a one time transit from Brunswick, GA to Gibson, LA with a temporary repair (welded doubler plate) on its port bow void. Upon arrival in Gibson, LA, this permit to proceed will be concluded and the owner/operator shall obtain permission from [name withheld] prior to any movement of the vessel. An inspection of the permanent repair is required prior to the vessel's return to service.
Action required: 15 - Rectify deficiencies by next port
Due 5 November 2021
Resolved 10 May 2022
Resolution: Repairs complete. Test Sat. Received CG 835 PTP from MSU Morgan City.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 October 2021
Resolved
No repairs affecting the safety of the vessel with regards to the hull shall be made without knowledge of the [name withheld] of the repairs shall be approved by the OCMI before work is started. An inspection either general or partial, depending on the circumstances, shall be made whenever any important repairs are undertaken.
Vessel was involved in an allision, putting a hole 4" x 12" hole approximately 2.5' above the waterline in the port side bow tank void.
Owner/operator shall propose a repair plan to be approved by the OCMI and the repair shall be deemed satisfactory to the attending MI prior to the movement of the vessel.
Action required: 60 - Rectify deficiencies prior to movement
Due 4 October 2021
Resolved 5 October 2021
Resolution: Vessel affect temporary repair satisfactory to ABS surveyor and USCG personnel, allowing vessel movement. Discsussions with owner/operator to provide permanent repair plans.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 30 March 2021
Resolved
Inspectors observed load line marking were painted on the sides of the vessel however the marks and rings did not appear to be permanently marked IAW 46 CFR 42.13-40. ABS assigned the load line and per ABS Steel Rules 2004 Appendix 1 Chapter 1, the ring and lines are to be permanently marked, as by center punch, chisel cut or bead of weld. Vessel must correct this by next dry dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 13 September 2022