Records from 1996 to 2025. Most recent: inspection, 15 April 2025.
Documentation record
Registered dimensions (L × B × D)51.4 ft × 18.0 ft × 6.3 ft
Registered tonnagegross 55 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEQUITABLE EQUIPMENT COMPANY INC · MADISONVILLE, LA, UNITED STATES · built 1966
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portTACOMA, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationCase Pending · issued 1 October 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it55 - Regulatory (Subpart C or D), Gross Ton
38 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
15 April 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8112395
7 August 2024
Inclining Experiment · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7975739
17 April 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7897210
5 July 2023
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7725652
14 June 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7477595
21 March 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7421087
28 July 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7284000
9 June 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7221012
5 June 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7220989
1 April 2019
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6654026
14 March 2019
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6642794
1 August 2018
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6498002
6 April 2018
Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6379480
20 May 2014
Damage Survey · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4863766
20 May 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4864711
4 February 2014
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4802295
19 September 2013
Administration
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4718666
19 February 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 141493
2 June 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 94580
5 April 1998
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 658353
22 January 1998
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 195819
10 June 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 168050
24 July 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 195818
24 July 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 760243
13 February 1996
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 716985
5 February 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 159896
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 15 April 2025
Resolved
142.330 Fire-detection system requirements.
(a) Fire-detection systems. Except as provided in paragraph (a)(8) of this section, each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the following:
(1) Each detector, control panel, remote indicator panel, and fire alarm are approved by the Commandant under approval series 161.002 or listed by a NRTL as set forth in 29 CFR 1910.7;
(2) The system is installed, tested, and maintained in accordance with the manufacturer's design manual;
(3) The system is arranged and installed so a fire in the engine room automatically sets off alarms on a fire detection control panel at the operating station. On vessels with more than one operating station, only one of them must be outfitted with a fire detection control panel. Any other operating station must be outfitted with either a fire detection control panel or a remote indicator panel
Fire detection system inoperable. Operator to have agency service system prior to carriage of passengers/cargo.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2025
Resolved 18 April 2025
Resolution: agency serviced system. Inspector attended 04/18 and verified functionality
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 15 April 2025
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector or TPO, as applicable. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections , maintenance procedures, and hydrostatic pressure tests. A tag issued by a qualified servicing organization, and attached to each extinguisher may be accepted as evidence that the necessary maintenance procedures have been conducted. 160B extinguisher did not have a tag attached.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2025
Resolved 18 April 2025
Resolution: AGOW serviced extinguishers on April 18. Inspector present and verified servicing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 August 2024
Resolved
Verification of compliance with the construction and arrangement design standard of this part must be performed before the new installation is performed on a vessel on which the new installation is not a "replacement in kind." Vessel owner/operator installed new engines that were not a "replacement in kind" without prior review and verification of design verification standards by a qualified individual or entity. Modifications included, but not limited to: changes from pneumatic controls to electronic, and exhaust cooling with addition of two independent keel coolers.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 March 2025
Resolution: Received documentation from PE, verified installations.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 7 August 2024
Resolved
The owner or managing operator of an existing vessel not operating under a stability document must be able to show at least one of the [criteria listed in §144.300(b)(1)-(3)]. Vessel owner/operator conducted not in-kind replacement of main engines, replacements/repositioning of lube oil tanks and hydraulic tank, and addition of independent keel coolers, with no established lightweight characteristics to measure changes against due to prior grandfathering of stability.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 January 2025
Resolution: Stability calculations received following succesful incline stablity test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 April 2024
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Exhaust lagging on port engine is deteriorated missing in places.
46 CFR 143.220(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2024
Resolved 24 April 2024
Resolution: Received pictures of installed lagging.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 5 July 2023
Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel did not have proof of FCC registration on-board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 13 July 2023
Resolution: Received photos clearing def.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 5 July 2023
Resolved
The bridge-to-bridge radiotelephone station will be inspected on vessels subject to regular inspections pursuant to the requirements of Parts II and III of Title III of the Communications Act. Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 13 July 2023
Resolution: Received photos clearing def.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 5 July 2023
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Vessel did not have records of testing or proof of enrollment in a maritime consortium available.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 13 July 2023
Resolution: Received photos clearing def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 March 2022
Resolved
Vessel temporarily lost steering in port engine due to a leak in control air. When the main steering gear includes two or more identical power units it must be capable of moving the rudder as required by 46 CFR 58.25-10 while all power units are operating. Re-seated o-ring, repaired leak and tested satisfactorily.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 March 2022
Resolution: Re-seated o-ring, repaired leak and tested satisfactorily.