MAURY USCG vessel records
← All vessels

PAYTON J

Built
2007
Last inspected
28 August 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 28 August 2025
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 16 calendar years (2007–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

910006
Flag
UNITED STATES
Maury page id
psix-910006

Documentation record

Registered dimensions (L × B × D)188.2 ft × 54.0 ft × 15.5 ft
Registered tonnagegross 1,151 / net 480
ITC dimensions (L × B × D)188.2 ft × 54.0 ft × 15.5 ft
ITC tonnagegross 1,151 / net 480
BuilderSUNDIAL MARINE · TROUTDALE, OR, UNITED STATES · built 2007
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN PEDRO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 23 March 2026 · expires 30 April 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1151 - Convention (Subpart B), Gross Ton
480 - Convention (Subpart B), Net Ton
2049 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 43 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ROBYN J Towing Vessel · MISLE 53120 · 10 May 2008 · activity 3213510

Inspection history · 43

28 August 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8210555
23 June 2025 Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8165731
5 May 2025 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8127663
14 November 2024 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8035061
22 October 2024 Periodic Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8023226
23 January 2024 Annual Inspection · MARPOL Annex I Examination · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7853662
19 December 2022 MARPOL Annex I Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7610758
2 November 2022 Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7588433
23 June 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7444942
18 January 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7407637
9 February 2021 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7138308
29 July 2020 Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7019184
11 February 2020 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6906587
16 October 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6563732
14 June 2018 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6444127
29 November 2017 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6306249
12 July 2017 Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6189588
17 February 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6086244
9 June 2016 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5940541
10 March 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5830662
28 January 2016 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5813070
20 November 2015 Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5786157
27 February 2015 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5074034
6 February 2014 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4789738
14 December 2012 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4501800
6 November 2012 Drydock Exam · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4481536
3 October 2012 Drydock Extension
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4460487
16 February 2012 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4245972
28 October 2011 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4178154
21 October 2010 Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3872843
16 February 2010 Deficiency Check · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3680679
8 February 2010 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3677113
11 January 2010 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3662023
17 June 2009 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3506823
2 May 2009 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3472364
19 March 2009 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3435714
17 February 2009 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3419310
3 February 2009 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3418967
12 May 2008 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3205375
10 May 2008 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3213510
4 January 2008 Initial Certification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3115869
19 November 2007 Construction Oversight · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3100705
23 October 2007 Construction Oversight
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3084732

Deficiency record · 13

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 October 2024 Resolved
Observed Conduit cable covers and housing for cargo alarms are not properly sealed within the hazardous area and housing compromised. The discussed temporary repair is authorized until 12NOV2024. Vessel may only carry Grade E cargoes until permanent repairs are completed and approved.
Action required: 705 - Other - as specified
Due 12 November 2024
Resolved 14 November 2024
Resolution: Permanent repairs completed, all SAT
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 24 October 2024 Resolved
Observed PIC open cargo hatch cover to #6 cargo tank, which released vapors into the atmosphere and created a hazardous situation. Company is to provide training and guidance to personnel regarding safe practices.
Action required: 703 - Prior to bunkering operations
Resolved 25 October 2024
Resolution: Company provided training to PIC. All SAT
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 October 2024 Resolved
Overfill and high level alarms not tested. Barge is not to conduct cargo operations until successful testing of all cargo tank alarms.
Action required: 705 - Other - as specified
Resolved 24 October 2024
Resolution: Observed high level and overfill alarms on all Cargo Tanks, ALL SAT
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 October 2024 Resolved
Back-up batteries to alarm system did not have proper voltage. Barge is not to conduct cargo operations until batteries are replaced.
Action required: 705 - Other - as specified
Resolved 24 October 2024
Resolution: Observed new batteries, ALL SAT
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 22 October 2024 Resolved
Cargo hatches did not have the proper markings of "Danger Keep Out," at no less than 3". Barge is to place proper signage on top of cargo hatches. 46CFR35.05-15
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 October 2024
Resolution: Observed proper signage. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 October 2024 Resolved
Observed Conduit cable cover under operating station not properly sealed within the hazardous area. Prior to cargo operations, cable covers are to be sealed within manufactures specification for hazardous area. The discussed temporary repair is authorized until 12NOV2024. Vessel may only carry Grade E cargoes until permanent repairs are completed and approved.
Action required: 705 - Other - as specified
Due 12 November 2024
Resolved 14 November 2024
Resolution: Permanent repairs completed, all SAT
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 22 October 2024 Resolved
Barge did not have warning signs at the gangway. Barge is to have a sign made and displayed while the vessel is moored or anchored unless it is empty and gas-freed. Sign shall be made with no less than 2" lettering of "WARNING No Open lights. No Smoking. No Visitors." 46CFR35.30-1
Action required: 705 - Other - as specified
Resolved 24 October 2024
Resolution: Observed signage. All SAT
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 29 November 2017 Resolved
Paint VAPOR PIPING in accordance with regulations.
Condition: Improper Installation
Due 7 December 2017
Resolved 5 December 2017
Documentation › Markings/Placards › Warning Signs
Issued 29 November 2017 Resolved
Paint deck warning sign red flag approrpriately with new red paint.
Condition: Improper/Lack of Maintenance
Due 7 December 2017
Resolved 5 December 2017
Electrical › Electric Generation Source (service) › Generator
Issued 16 February 2010 Resolved
Electrical generator is inop. Make proper repairs and prove proper operation of generator.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 5 March 2010
Resolution: Generator replaced. Operationally tested SAT.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 11 January 2010 Resolved
Provide life line and retroreflective material to ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2010
Resolved 8 February 2010
Resolution: Provided life line and retrorelective material to ring buoy.
Deck/Cargo › Vapor Control Systems › Vapor Recovery Unit
Issued 4 January 2008 Resolved
VCS is restricted from operation until approval letter is received.
Action required: 705 - Other - as specified
Due 4 January 2008
Resolved 4 January 2008
Resolution: Letter received dated 26 Dec 2007.
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 4 January 2008 Resolved
Provide flame screens for all cargo hatches.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 29 February 2008
Resolution: Installed.

Ownership record