Records from 2006 to 2012. Most recent: inspection, 7 May 2012.
Inspection history · 5
7 May 2012
Marine Casualty Follow Up
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4304571
3 May 2012
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4302035
25 November 2008
Uninspected Other
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3369574
9 November 2007
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3095960
20 June 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3015436
Personnel › Certificates/Documents/Licenses › License, Master
Issued 25 November 2008
Resolved
Provide valid master's license. 46 CFR Part 10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: Valid document provided to attending marine inspector.
Engineering › Fuel Oil Service System › Valve
Issued 25 November 2008
Resolved
Provide fuel shut off valves (remote) operable from outside the engine room 46 CFR 27.207
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: Pull cables installed in pilothouse. Verifed operation of fuel shutoffs.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 25 November 2008
Resolved
Provide fire suppression system IAW 46CFR 27.303
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: Owner/operator installed Sea Fire FE-241 1500 system. Verifed operation of engine shutdowns and alarms.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 25 November 2008
Resolved
Repair/replace port engine leaking raw water piping.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: Raw water piping repaired. Tested system, no leaks apparent.
Fire Fighting › Fire Pumps › Location
Issued 25 November 2008
Resolved
Provide fire pump IAW 46 CFR 27.301
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: Installed portable fire pump. Verified operation of pump.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 25 November 2008
Resolved
Provide a fire detection system IAW 46 CFR 27.203
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: Vessel installed a fixed fire extinguishing systems capable of automatic discharge upon heat detection. Verifed operation of alarms and resets.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 25 November 2008
Resolved
Provide proof of portable fire extinguishers servicing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: Portable fire extinguishers were renewed.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 25 November 2008
Resolved
Remove jumper cables from port and stbd engines. Jumper cables are being used to supply starter voltage from stbd starter to port starter due to port battery bank not holding a charge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: Jumper cables removed. Stbd alternator replaced. Verified operation of main engines.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 25 November 2008
Resolved
Remove oil from engine room bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: Engine room and bilges clean of oil.