Records from 1996 to 2024. Most recent: inspection, 21 June 2024.
Inspection history · 28
21 June 2024
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7941101
22 December 2023
TPO Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7841028
4 April 2023
Annual Inspection · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7662266
23 September 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7470135
2 August 2022
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7523079
3 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7443227
28 September 2021
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7327253
24 August 2021
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7295198
20 August 2020
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7053271
3 August 2020
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7023148
5 March 2019
Administrative Inspection · Initial Certification · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6636681
30 June 2017
Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6195540
29 March 2016
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5844669
2 April 2014
Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4828809
8 September 2011
Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4140003
5 April 2005
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2327053
6 January 2005
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2272885
18 May 2004
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2071212
19 September 2002
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1677816
2 January 2001
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 133276
3 November 2000
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 286274
28 September 2000
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 823574
19 September 2000
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 213705
2 September 1999
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1118030
30 August 1999
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 212485
18 December 1996
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1099044
28 March 1996
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1079634
27 March 1996
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 98632
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 September 2022
Resolved
Except as provided by paragraph (b) of this section, each navigation light must - (1) Meet the technical standards of the applicable Navigation Rules; (2) Be certified by a laboratory listed by the Coast Guard to the standards of ABYC A-16 (incorporated by reference, see § 183.5) or equivalent, although portable battery-powered lights need only meet the requirements of the standard applicable to them. Bow light has non-approve bulb installed and starboard running light inoperative. Repair lights as required.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2022
Resolved 21 October 2022
Resolution: Light fixture replaced with new
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 September 2022
Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. 1000 lb concrete block on port side 01 deck. Remove block from vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2022
Resolved 21 October 2022
Resolution: Weight removed from vessel
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Electrical outlet on stern main deck and under port propulsion engine missing cover. Repair outlets or remove from service.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2022
Resolved 21 October 2022
Resolution: All outlets repaired
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 September 2022
Resolved
Means must be provided for closing, in case of fire, each machinery space doorway, ventilator, and annular space around funnels. Stack space vents are fixed with no way to secure. Provide method to close vents.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2022
Resolved 21 October 2022
Resolution: Ventilation louvers installed on stack spaces
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 September 2022
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation. Starboard propulsion governor assembly held together by zip ties. Repair assembly to original condition.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2022
Resolved 21 October 2022
Resolution: Governor assembly repaired with manufacturer's parts
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 14 September 2021
Resolved
Each towing vessel must be operated in compliance with applicable sections of the Federal Water Pollution Control Act, including section 311 of the Federal Water Pollution Control Act. Bottom of flammable liquids storage locker full of oil leaking from containers and then leaking onto the deck. Clean out flammable liquids storage locker and dispose of liquids as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2021
Resolution: Flam locker cleaned and leaking containers removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 September 2021
Resolved
Life jackets must have the following attachments and fittings: (1)Each life jacket must have a life jacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the life jacket. (2) Each life jacket must have a whistle firmly secured by a cord to the life jacket. One life jacket in engine room was found with a missing light. One life jacket in engine room found with missing light and whistle.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2021
Resolution: Life jacket was extra. Life jacket removed from vessel
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 September 2021
Resolved
Stowage positions for lifejackets must be marked in block capital letters and numbers with the minimum quantity, identity, and, if sizes other than adult or universal sizes are used on the vessel, the size of the lifejackets stowed inside the container. Life jacket storage containers missing number of lifejackets throughout the vessel. Add quantity as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2021
Resolution: Life jacket containers properly labeled.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 September 2021
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the system is installed, tested, and maintained in accordance with the manufacturer's design manual. Fire detection panel displayed a trouble alarm. Repair as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2021
Resolution: New battery installed on panel, trouble cleared.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 14 September 2021
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT HATCH - KEEP CLOSED”. All watertight hatches missing labels. Mark hatches as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2021
Resolution: Hatches and doors properly labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 September 2021
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation. Bungy cord was found being used to control port engine governor. Repair engine to manufactures specifications.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2021
Resolution: Engine repaired with proper parts.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 September 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Electrical distribution panel in lower engine room has missing breakers/blanks in panel posing a shock hazard. Install breakers or blanks as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2021
Resolution: Blanks installed as required.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 September 2021
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Documentation for testing alarm set points, pressure relief valves, and other essential systems not found. Conduct testing and document as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2021
Resolution: Testing documentation provided.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 14 September 2021
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. Railing missing on stern of vessel. Install as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2021
Resolution: Railing installed as required.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 14 September 2021
Resolved
Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Label for valves is not at valve location and no operation instruction is provided. Install labels as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2021
Resolution: Labeled as required.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 13 August 2020
Resolved
Portable firepump must operate with a minimum capacity of at least 80 gpm at not less then 50 psi. Its nozzle must be capable of providing a solid stream pattern. During drill portable pump was unable to meet flow and pressure requirements. Also, nozzle was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2020
Resolved 13 August 2020
Resolution: Received video evidence of completed repair
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 August 2020
Resolved
Fire detection system must be inspected or tested once every 12 months. Last documented maintenance was performed March 2019.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 20 August 2020
Resolution: Recieved obj evidence fire detection system was serviced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 August 2019
Resolved
Electrical equipment must function properly and minimize system failures, fire, and shock hazards. Portable battery charger sitting freely on engine room deck, air compressor electrical supply enclosure, and port engine light fixture present fire and shock hazards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 27 September 2019
Resolution: Equipment secured and the port engine light fixture was removed from the engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 August 2019
Resolved
Electrical systems must be designed and maintained to provide for safe operation of towing and persons on board. Battery housing cover cannot be secured and general battery cleanliness and maintenance inadequate for safe storage and use.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 27 September 2019
Resolution: Battery housing cover secured and battery maintenance was conducted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 August 2019
Resolved
Flammable and combustible products must not be stored in machinery spaces. Hydraulic oil containers are being stored in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 27 September 2019
Resolution: Deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 August 2019
Resolved
All bilges must be kept free from accumulation of combustible materials. Oil and rags discovered in engine room bilges under both main propulsion engines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 27 September 2019
Resolution: Deficiency cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 20 August 2019
Resolved
All exposed hazards such as rotating machinery must be protected with a cover. Starboard main propulsion engine has exposed rotating machinery at propulsion shaft.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 27 September 2019
Resolution: Protection cover provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 August 2019
Resolved
Emergency fuel shutoff valves must be installed at the fuel source. Emergency fuel shutoff valves discovered at the engines and not the source of fuel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2019
Resolved 27 September 2019
Resolution: Emergency shutoff valves installed at the source of fuel.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 20 August 2019
Resolved
Existing vessels must must be able to show proof that vessel has satisfactory service history or operational tests to satisfy the Coast Guard that it has adequate stability and handling characteristics. There is no documented proof on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 27 September 2019
Resolution: Stability documentation provided on board.
01 - Certificates & Documentation › 013 - Documents › Ship specific plans for the recovery of persons from the water
Issued 20 August 2019
Resolved
Vessel must have an accurate list of crewmembers and their assigned duty positions during an emergency. Emergency duty assignments that are posted do not reflect the actual manning and crew assignments.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 27 September 2019
Resolution: Vessel specific emergency duty assignments provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 August 2019
Resolved
Piping for flammable or combustible liquid, seawater cooling, or fire fighting systems must be fitted with isolation valves that are clearly marked by labeling or color coding to identify its function. Vessel piping does indicated systems they serve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 27 September 2019
Resolution: Vessel’s piping marked and a color coding indication sheet was posted in the engine room.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 20 August 2019
Resolved
Vessel must have a record of the type, size, and service of each towline, face wire, and spring line used to make the towing vessel fast to her tow. Records must show dates when examinations were performed, the identification of each towing gear examined, and names of the persons conducting examinations. No records on board that examinations are being performed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 27 September 2019
Resolution: Towing gear record provided.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 20 August 2019
Resolved
Fuel systems for towing vessel main engines and generators must have a documented maintenance plan to ensure proper operation of the system. No documented plan on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 27 September 2019
Resolution: Documented maintenance plan provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 August 2019
Resolved
Vessel is required to display proper dayshapes or navigation lights when aground, restricted in ability to maneuver, or not under command. No dayshapes or navigation lights on board for aground, restricted in ability to maneuver, or not under command.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2019
Resolved 27 September 2019
Resolution: The day shapes and nav lights requirement is deferred.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 August 2019
Resolved
Towing vessels must be equipped with the navigations lights as appropriate to its area of operation. Vessels Port and Starboard sidelights observed to be inoperable. Vessel restricted from operating between sunset and sunrise or during periods of restricted visibility.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 27 September 2019
Resolution: Vessel's Port and Starboard sidelights observed to be operable.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 20 August 2019
Resolved
Vessels magnetic compass must be visible from the operating station. Magnetic compass on board found loose, not properly mounted, and twisted obscuring visibility.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 27 September 2019
Resolution: Magnetic compass secured.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 August 2019
Resolved
Portable fire extinguishers shall be installed on a hanger intended for the extinguisher, in a bracket supplied by the manufacturer, or in a listed bracket approved for such purpose. Portable fire extinguishers on board not installed in appropriate bracket per NFPA 10 6.1.3.4, incorporated by reference 46 CFR 136.112
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 27 September 2019
Resolution: Fire extinguishers provided in the wheel house and near the combustibles cabinet are secured in appropriate brackets.