Records from 1991 to 2026. Most recent: inspection, 14 May 2026.
Inspection history · 22
14 May 2026
Deficiency Check · Administrative Inspection · Drydock Exam · Internal Structural Exam · Vessel Attendance · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8373836
7 August 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8215767
29 July 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7970068
15 March 2024
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7879687
30 May 2023
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7694903
5 August 2022
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7525327
10 May 2022
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7444373
10 May 2021
Deficiency Check · Initial Certification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7184508
19 November 2020
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7098777
21 November 2019
Damage Survey · Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6860025
10 September 2019
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6808879
6 September 2019
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6805627
19 January 2018
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6339868
14 November 2017
MTSA Verification · Industry Initiated Exam · Administration
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6293464
8 October 2015
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5795572
2 July 2015
MTSA Verification · Industry Initiated Exam · DAPI Audit
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5175230
14 March 2011
DAPI Audit · MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3966337
13 November 2005
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2534284
10 November 2005
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2532214
24 October 1996
MARPOL Annex I Examination · MARPOL Annex V Examination · Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1163505
23 September 1996
Uninspected Towing Vessel · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1443748
5 August 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 665617
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 29 July 2024
Resolved
All towing vessels must be equipped with steering compass readable from main steering station. Vessel was not equipped with steering compass.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 30 August 2024
Resolution: Video sent.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 July 2024
Resolved
Vessel must carry adequate and up-to-date charts, including electronic charts acceptable to the Coast Guard. Vessel's electronic charts were not acceptable.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 30 August 2024
Resolution: Picture sent.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 30 May 2023
Resolved
The following systems must be equipped with gauges at the machinery location: Hydraulic steering fluid pressure, if the vessel is equipped with hydraulic steering systems. Both steering pump gauges were not operational. Make repairs or replace gauges and prove proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 12 June 2023
Resolution: Received satisfactory photographic evidence of compliance.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 30 May 2023
Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or
otherwise guarded to prevent burns. On a new vessel, each pipe that contains vapor, gas, or liquid that has a temperature exceeding 150 °F (65.5 °C) which is within reach of personnel must be insulated where necessary or
otherwise guarded to prevent injury. The exhaust lagging around the port generator turbo is missing. Replace lagging.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 12 June 2023
Resolution: Received satisfactory photographic evidence of compliance.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 May 2023
Resolved
Each fire hose must be a lined commercial fire hose 15 meters (50 feet) in length. The fire hose onboard is 75 feet in length and due to the length may pose an additional safety hazard. Replace the existing hose with a 50 foot hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 12 June 2023
Resolution: Received satisfactory photographic evidence of compliance.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 May 2023
Resolved
For the storage of flammable or combustible products, if a dedicated storage cabinet is provided it must be secured to the vessel so that it does not move. The current storage cabinet is secured with a deteriorated ratchet strap. Properly secure the cabinet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 12 June 2023
Resolution: Received satisfactory photographic evidence of compliance.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 30 May 2023
Resolved
All machinery and equipment that is not in proper working order (including missing or malfunctioning guards or safety devices) must be removed; made safe through marking, tagging, or covering; or otherwise made unusable. Adequate guards are not in place around the rotating shaft coupling and main engine rotating pulleys. Provide adequate guards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 12 June 2023
Resolution: Received satisfactory photographic evidence of compliance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The negative cable on the starboard battery bank is not properly terminated. Properly terminate cable to battery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 12 June 2023
Resolution: Received satisfactory photographic evidence of compliance.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 May 2022
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. Port navigation light is inoperative. Vessel limited to daylight operation only until permanent repairs are completed to the satisfaction of the Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 17 May 2022
Resolution: Received objective evidence that the port nav light was replaced and is operating properly.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 May 2022
Resolved
In addition to the requirements in paragraph (a) of this section, all fire-suppression and detection equipment and systems on board a towing vessel must be maintained in accordance with the attached nameplate, manufacturer's approved design manual, or as otherwise provided in any TSMS applicable to the vessel. Fire pump discharge flange has excessive leakage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 17 May 2022
Resolution: Received objective evidence that the fitting that was leaking excessively was properly replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 May 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Racor filter flame shield missing. Replaced while onboard.
Action required: 10 - Deficiency Rectified
Due 10 May 2022
Resolved 10 May 2022
Resolution: 10 c
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 May 2022
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217 (incorporated by reference, see § 136.112 of this subchapter). Detection systems or individual detectors must be kept operational at all times when the crew is onboard the towing vessel. Found dead battery in smoke detector in accommodation space. Replaced while onboard.
Action required: 10 - Deficiency Rectified
Due 10 May 2022
Resolved 10 May 2022
Resolution: 10 c
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 10 May 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2021
Resolution: Captain received valid medical certificate
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2021
Resolved
EACH TOWING VESSEL MUST CARRY AT LEAST ONE APPROPRIATELY SIZED LIFEJACKET APPROVED UNDER APPROVAL SERIES 160.002, 160.005, 160.055, 160.155 OR 160.176. THE LIFEJACKETS CARRIED ONBOARD WERE APPROVED UNDER APPROVAL SERIES 160.060. PROVIDE APPROPRIATE NUMBER OF PROPERLY APPROVED LIFEJACKETS PRIOR TO GETTING UNDERWAY.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2021
Resolution: Lifejackets were replaced with proper type I lifejackets
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 May 2021
Resolved
A TOWING VESSEL MUST CARRY A COMBINATION OF DAY AND NIGHT VISUAL DISTRESS SIGNALS INDICATED IN TABLE 141.370 OF §141.370 FOR SPECIFIED AREAS WHERE THE VESSEL OPERATES. ESSEL OPERATES ON A RIVERS ROUTE REQUIRING 3 DAY AND 3 NIGHT EMERGENCY SIGNALS. VESSEL ONLY HAS 3 NIGHT SIGNALS ON BOARD. PROVIDE ONBOARD DAY SIGNALS THAT MEET 46 CFR 141.375 PRIOR TO GETTING UNDERWAY
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: Additional flares were provided onboard
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 May 2021
Resolved
EACH TOWING VESSEL MUST HAVE EITHER A SELF-PRIMING, POWER-DRIVEN OR FIXED FIRE PUMP CAPABLE OF BEING ENERGIZED REMOTELY FROM A SAFE PLACE OUTSIDE THE ENGINE ROOM AND AT THE PUMP. VESSEL'S ONBOARD FIREPUMP IS ONLY CAPABLE OF BEING ENERGIZED FROM A SAFE PLACE OUTSIDE THE ENGINE ROOM. VESSEL WILL PROVIDE A CAPABILITY TO ENERGIZE AT THE FIRE PUMP TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2021
Resolved 17 May 2021
Resolution: Vessel installed a switch local to the firepump
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 September 2019
Resolved
A VESSEL MUST BE OPERATED IN ACCORDANCE WITH APPLICABLE LAWS AND REGULATIONS AND IN SUCH A MANNER AS TO AFFORD PROTECTION AGAINST HAZARDS TO LIFE, PROPERTY, AND THE ENVIRONEMENT. VESSEL WAS SET UP WITH AN OPERATING PORTABLE PUMP IN THE RUDDER ROOM DUE TO THE INFLUX OF WATER FROM UNKNOWN DAMAGE. RUDDER ROOM WAS BEING PUMPED INTO THE RIVER AS A GENERAL OPERATING MECHANISM NOT SOLEY AS EMERGENCY DEWATERING. IDENTIFY DAMAGE SUSTAINED IN RUDDER ROOM AND MAKE PROPER REPAIRS.
46 CFR 140.205(a)
Action required: 30 - Ship detained
Due 20 September 2019
Resolved 10 May 2021
Resolution: Vessel hull was completely redone at shipyard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 September 2019
Resolved
A VESSEL MUST BE OPERATED IN ACCORDANCE WITH APPLICABLE LAWS AND REGULATIONS AND IN SUCH A MANNER AS TO AFFORD PROTECTION AGAINST HAZARDS TO LIFE, PROPERTY, AND THE ENVIRONEMENT. A PORTABLE BILGE PUMP IN THE MACHINERY SPACE BILGE WAS CONNECTED TO THE STARBOARD FIRE MAIN PIPING AND WAS SET UP TO PUMP OVER THE SIDE AS A GENERAL OPERATING MECHANISM DUE TO THE INFLUX OF WATER FROM THE PORT AND STARBOARD SHAFT PACKING, NOT SOLEY FOR EMERGENCY DEWATERING. PORTABLE BILGE PUMP IS AUTHORIZED BUT SHOULD ONLY BE USED FOR EMERGENCY DEWATERING. SHAFT PACKINGS ARE TO BE REPAIRED MINIMIZING INFLUX OF WATER INTO THE ENGINEROOM.
46 CFR 140.205(a)
Action required: 30 - Ship detained
Due 20 September 2019
Resolved 10 May 2021
Resolution: Repairs were made while at drydock.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 September 2019
Resolved
EACH TOWING VESSEL MUST HAVE A RELIABLE MEANS TO PROVIDE
NOTIFICATION WHEN AN EMERGENCY CONDITION EXISTS, A HIGH BILGE LEVEL ALARM SHALL BE PROVIDED. THE MASTER OF THE VESSEL COULD NOT IDENTIFY WHETHER OR NOT THE VESSEL WAS EQUIPPED WITH A HIGH LEVEL ALARM. PROVE PROPER OPERATION OF AN INSTALLED HIGH BILGE LEVEL ALARM.
46 CFR 143.230(a)(5)
Action required: 30 - Ship detained
Due 20 September 2019
Resolved 10 May 2021
Resolution: Installed and tested satisfactorily
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 September 2019
Resolved
EACH TOWING VESSEL MUST HAVE EITHER A SELF-PRIMING POWER DRIVEN FIXED FIRE PUMP OR A PORTABLE FIRE PUMP. THE MASTER OF THE VESSEL COULD NOT DEMONSTRATE THE VESSEL'S FIXED FIRE PUMP OPERATION. PROVE PROPER OPERATION OF THE VESSEL'S FIRE PUMP.
46 CFR 142.325
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2019
Resolved 10 September 2019
Resolution: Witnessed operation of the fixed fire pump.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 September 2019
Resolved
ELECTRICAL SYSTEMS AND EQUIPMENT MUST FUNCTION PROPERLY AND MINIMIZE SYSTEM FAILURES, FIRE AND SHOCK HAZARDS. VESSEL'S PORT SHIP SERVICE GENERATOR AND PRIME MOVER WERE SATURATED/COATED IN OIL POSING A FIRE HAZARD. PROPERLY CLEAN PORT SSG TO MINIMIZE FIRE HAZARDS AND REPAIR OIL LEAKS.
46 CFR 143.400(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2019
Resolved 10 September 2019
Resolution: Port SSDG was wiped up and appeared not to be a fire hazard.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 September 2019
Resolved
EACH TOWING VESSEL MUST BE MAINTAINED TO MINIMIZE FIRE HAZARDS AND TO ENSURE ALL BILGES AND VOID SPACES ARE KEPT FREE FROM ACCUMULATION OF COMBUSTIBLE AND FLAMMABLE MATERIALS AND LIQUIDS INSOFAR AS PRACTICABLE. THE FOLLOWING WAS IDENTIFIED:
-STORAGE CAN CONTAINING GASOLINE WAS SITTING NEXT TO THE STBD SSG BATTERY CHARGER
-BILGE CONTAINED EXCESSIVE OIL
-PAINT CANS WERE STORED IN THE OPEN AREA OF THE UPPER ENGINE ROOM. REMOVE POTENTIAL FIRE HAZARD MATERIALS AND PLACE IN APPROPRIATE STORAGE LOCKER.
46 CFR 142.220
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2019
Resolved 10 May 2021
Resolution: All hazardous materials were removed or properly stowed in flammable locker.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 September 2019
Resolved
ELECTRICAL COMPONENTS THAT POSE AN ELECTRICAL HAZARD MUST BE IN AN ENCLOSURE. SEVERAL WIRES WERE CUT AND LEFT EXPOSED STICKING OUT OF THE ENGINE ROOM POWER DISTRIBUTION PANEL LOCATED ON THE UPPER LEVER PORT SIDE. REMOVE UNUSED ELECTRICAL CABLE OR PROVIDE APPROPRIATE ENCLOSURE.
46 CFR 143.400(g)
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: Wires were removed and panel blanked off.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 6 September 2019
Resolved
THE OFFICER IN CHARGE OF A NAVIGATIONAL WATCH MUST CONDUCT A NAVIGATION ASSESSMENT FOR THE INTENDED ROUTE AND OPERATION PRIOR TO GETTING UNDERWAY. THE VESSEL WAS OBSERVED TO BE UNDERWAY AND THE MASTER STATED THAT HE HAD NOT YET DONE A NAVIGATION ASSESSMENT NOR COULD ANY ASSESSMENT BE FOUND FOR PREVIOUS VOYAGES. PROVIDE APPROPRIATE NAVIGATION ASSESSMENT RECORDS.
46 CFR 140.635(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2019
Resolved 10 May 2021
Resolution: Navigation assessments are available and training by O/O was provided to Master. Vessel has not been underway so no completed assessments were available.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 September 2019
Resolved
CREW MEMBERS MUST MEET THE REQUIREMENTS IN 15.405 AND 15.1105 OF THIS CHAPTER, AS APPROPRIATE. THE MASTER AND DECKHAND COULD NOT DEMONSTRATE KNOWLEDGE OF THE VESSEL CHARACTERISTICS, RESPONDING TO FIRES, AND RESPONDING TO FLOODING EMERGENCIES. MASTER ASSUMED COMMAND OF THE VESSEL WITHOUT WORKING KNOWLEDGE OF THE VESSEL. VESSEL CREW MUST PROVE UNDERSTANDING OF THE VESSEL AND ITS EMERGENCY EQUIPMENT AND THEIR DUTIES.
46 CFR 140.405(a)
Action required: 10 - Deficiency Rectified
Resolved 11 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 September 2019
Resolved
EACH TOWING VESSEL MUST CARRY AT LEAST ONE APPROPRIATELY SIZED LIFEJACKET APPROVED UNDER APPROVAL SERIES 160.002, 160.005, 160.055, 160.155, OR 160.176. THE ONLY LIFEJACKETS PRESENTED TO THE MARINE INSPECTOR WERE MARKED AS WORKVESTS. PROVIDE APPROPRIATE LIFEJACKETS.
46 CFR 141.340(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2019
Resolved 10 September 2019
Resolution: Vessel has 4 approved life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 September 2019
Resolved
EACH LIFEBUOY ON A TOWING VESSEL MUST HAVE THE FOLLOWING ATTACHMENTS AND FITTINGS (1) ATLEAST ONE LIFEBUOY MUST HAVE A LIFELINE, SECURED AROUND THE BODY OF THE LIFEBUOY. IF MORE THAN ONE LIFEBOUY IS CARRIED, AT LEAST ONE MUST NOT HAVE A LIFELINE ATTACHED. VESSEL HAS TWO LIFEBOUYS EACH WITH LIFE LINES IMPROPERLY ATTACHED. PROPERLY ATTACH LIFELINE AND REMOVE LIFELINE FROM SECOND LIFEBUOY.
46 CFR 141.360(b)
Action required: 10 - Deficiency Rectified
Due 6 September 2019
Resolved 11 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 September 2019
Resolved
AT LEAST TWO LIFEBUOYS ON A TOWING VESSEL GREATER THAN 26 FEET MUST BE FITTED WITH A FLOATING ELECTRIC WATER LIGHT. VESSEL DID NOT HAVE ANY LIGHTS ATTACHED TO THEIR LIFEBOUYS. PROVIDE A WATER LIGHT ON AT LEAST TWO LIFEBUOYS.
46 CFR 141.360(c)(2)
Action required: 10 - Deficiency Rectified
Due 6 September 2019
Resolved 11 September 2019
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 6 September 2019
Resolved
CLOSURE DEVICES MUST BE PROVIDED FOR HULL PENETRATIONS, WHICH OPEN TO THE EXTERIOR OF THE VESSEL AND WHICH MAY ALLOW WATER TO ENTER THE VESSEL. 6 PENETRATIONS WERE FOUND BELOW THE WATER LINE WITH NO CLOSURE DEVICES, 2 LOCATED ON THE PORT SIDE AND 4 LOCATED ON THE STBD SIDE OF THE ENGINEROOM. INSTALL APPROPRIATE CLOSURE DEVICES.
46 CFR 144.320
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2019
Resolved 17 May 2021
Resolution: All overboard valves inspected SAT
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 6 September 2019
Resolved
MACHINERY AND FUEL TANK SPACES MUST BE SEPERATED FROM ACCOMMODATION SPACES BY BULKHEADS. VESSEL HAS MULTIPLE CABLE RUN OPENINGS IN THE ENGINE ROOM OVERHEAD ALLOWING FREE PASSAGE OF FIRE AND SMOKE TO ACCOMMODATION SPACES. CREW WAS AWARE AND TRIED TO FIX BY STUFFING TOWELS AND RAGS INTO THE OPENING. PROVIDE PROPER SEPERATION BETWEEN THE ENGINE ROOM AND THE ACCOMMODATION SPACE
46 CFR 144.410
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2019
Resolved 10 May 2021
Resolution: All penetrations were properly packed establishing a seperation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 September 2019
Resolved
PROPULSION MACHINERY, INCLUDING MAIN ENGINES, REDUCTION GEARS, SHAFTING, BEARINGS AND ELECTRICAL EQUIPMENT MUST: (1) BE MAINTAINED TO ENSURE PROPER OPERATION. STDB MAIN PROPULSION ENGINE WAS MODIFIED WITH A SOUP CAN TO COVER AN OPENING IN THE INBOARD VALVE COVER. MAKE APPROPRIATE REPAIRS TO ENDING INBOARD VALVE COVER.
46 CFR 143.205(c)
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2019
Resolved 10 September 2019
Resolution: Soup can was replaced with a proper cap.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 September 2019
Resolved
ELECTRICAL EQUIPMENT AND ELECTRICAL CABLES MUST BE SUITABLY PROTECTED FROM WET AND CORROSIVE ENVIRONMENTS. THE BATTERY CHARGER IS UNMOUNTED AND SITTING ON THE DECK OF THE ENGINE ROOM WHICH CONTAINS EXCESSIVE WATER AND OILY WASTE.
46 CFR 143.400(f)
Action required: 10 - Deficiency Rectified
Due 6 September 2019
Resolved 10 September 2019
Resolution: Battery charger was temporally fixed to the stair well with zip ties.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 September 2019
Resolved
ELECTRICAL CONNECTIONS MUST BE SUITABLY INSTALLED TO PREVENT THEM FROM COMING LOOSE THROUGH VIBRATION OR ACCIDENTAL CONTACT. MULTIPLE EXTENSION CORDS ARE RUN IN THE OVERHEAD TO POWER VARIOUS TYPES OF EQUIPMENT, FOR EXAMPLE THE SUMP PUMP THAT IS PIPED INTO THE STBD SIDE FIRE STATION DECK VALVE, USED TO DISCHARGE OILY BILGE WATER OVERBOARD. MAKE CONNECTIONS MORE PERMANENT THAN USE OF EXTENSION CORDS.
46 CFR 143.400(e)
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2019
Resolved 10 September 2019
Resolution: Extension cords were taken down.