Records from 2008 to 2023. Most recent: inspection, 24 April 2023.
Inspection history · 22
24 April 2023
Load Line/Change of Employment
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7675082
4 February 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6619722
6 December 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6593178
2 February 2018
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6349588
18 December 2017
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6325800
12 October 2017
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6288582
14 October 2016
COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6022507
4 February 2016
Annual Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5807955
4 February 2016
Deficiency Check · Examination of Repairs
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5812301
26 January 2016
Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5803647
12 March 2015
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5083020
20 February 2015
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5072079
26 December 2013
Deficiency Check · Periodic Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4773406
5 June 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4334935
11 January 2012
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4222771
1 December 2011
MARPOL Annex VI Survey · Internal Structural Exam · Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4199613
26 October 2011
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4177312
2 December 2010
DAPI Audit · MTSA Verification · MARPOL Annex VI Survey · Periodic Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3902609
13 January 2010
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3663078
10 January 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3661976
15 December 2009
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3642421
19 November 2008
MTSA Verification · Initial Certification · Deadweight Survey · DAPI Audit · MARPOL Annex I Examination · Plan Review (Other than "T") · Construction Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3366098
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 24 April 2023
Resolved
A vessel that is not usually engaged on domestic voyages by sea or on voyages on the Great Lakes but that, in exceptional circumstances, is required to undertake a single such voyage between two specific ports is—Issued a single voyage load line authorization by the Commandant that states the conditions under which the voyage may be made and any additional safety measures required for a single voyage.
Barge is required to have an up to date tow plan for this evolution.
46CFR42.03.25(f)(2)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 April 2023
Resolution: Tow Plan was sent to our office. All sat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 December 2017
Resolved
The original certificate of inspection was not onboard. Vessel had a copy and the original was kept at the Company's office. The original needs to be onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 8 January 2018
Construction/Loadline › Markings › Load Line Mark
Issued 18 December 2017
Resolved
Vessel's load line was not permanently marked.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 8 January 2018
Resolution: Received class report. Load line was punched into the hull of vessel.
Construction/Loadline › Hull › Side Shell
Issued 26 January 2016
Resolved
Internals in the Void No. 5 (Frame 3 & 4 from aft) were fractured/deformed and side shell in the way set in about 6”
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 10 February 2016
Resolution: Satisfactory repairs complete.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 20 February 2015
Resolved
The required manual shutdown for the port and stbd cargo pump engines were rendered ineffective by a non original manufacturer spec linkage connecting the cable to the engine shutdown. While the worn/stretched linkage was replaced with stronger material, an original spec linkage must be ordered and installed to complete the repair.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 May 2015
Resolved 7 May 2015
Resolution: Received tech report and verified that cargo pump shutdowns are operational.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 20 February 2015
Resolved
The electronic ground detection system in place on the 120V distribution panel carries a minimum rating of 208V. Replace with suitably sensitive ground detection system for 120V.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 March 2015
Resolved 12 March 2015
Resolution: Attended vessel to clear 110v distribution panel ground detection def. Switched all breakers in the 110 distribution box to "on" and tested ground detection. All sat.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 18 January 2012
Resolved
Rcvd notice from vessel that anchor motor had failed after dragging anchor.
Action required: 705 - Other - as specified
Resolved 23 January 2012
Resolution: Witnessed proper operation of anchor and motor.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 January 2012
Resolved
Prove proper operation of nav lights. (Def made prior to cargo due to other defs needing to be fixed prior to cargo as well. Vessel had on board portable lights.)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Resolution: Attended vessel and witnessed satisfactory operation.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 11 January 2012
Resolved
Prove proper operation of cargo pump shutdowns.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Resolution: Attended vessel and witnessed satisfactory operation.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 11 January 2012
Resolved
Prove proper operation of overspeed shutdown for generators.
Action required: 705 - Other - as specified
Due 11 February 2012
Resolved 23 January 2012
Resolution: Wtinessed proper operation of overspeed protection.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 11 January 2012
Resolved
Prove proper operation of lube oil shutdown for generators.
Action required: 705 - Other - as specified
Due 11 February 2012
Resolved 13 January 2012
Resolution: Attended vessel and witnessed satisfactory operation.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 11 January 2012
Resolved
Provide further inspection details for manned operations. Vessel was unprepared to prove that permissive manning requirements were capable of being met. Must prepare these inspection requirments prior to sailing permissively manned.
Action required: 705 - Other - as specified
Resolved 23 January 2012
Resolution: Witnessed proper equipment and functionality of vessel for manned operations.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 January 2010
Resolved
Submit VCS cargo approval request for ehtyl alcohol and additional cargoes to USCG Marine Safety Center for review and approval, adding any requested "D" cargoes to COI CAA.
Due 12 March 2010
Resolved 10 March 2010
Resolution: Vessel rep (Brendan MacGillvray) provided updated cargo approval list for authorization with VCS. Attached in MISLE documentation.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 January 2010
Resolved
Provide all ABS approval letters for VCS systm on barge, as referenced on COI and CG approval letter.
Due 12 March 2010
Resolved 10 March 2010
Resolution: Vessel Rep (Brendan MacGillivray) provided ABS letters.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 15 December 2009
Resolved
Provide proof of annual testing of cargo pump relief valves.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2009
Resolved 17 December 2009
Resolution: Certificate of testing provided.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 15 December 2009
Resolved
Renew/Replace missing damaged hose clamps on vapor tight covering around cargo pump shaft between deck house and cargo pump; port and stbd side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2009
Resolved 17 December 2009
Resolution: Hose clamps installed.