Inspection record

Last inspected 24 March 2025
…with no type recorded14
Operational controls None recorded without a removal date
Years with a record 18 calendar years (2007–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

922416
Flag
UNITED STATES
Maury page id
psix-922416

Documentation record

Registered dimensions (L × B × D)277.0 ft × 78.0 ft × 24.0 ft
Registered tonnagegross 4,110 / net 2,442
ITC dimensions (L × B × D)277.0 ft × 78.0 ft × 24.0 ft
ITC tonnagegross 4,110 / net 2,442
BuilderZIDELL MARINE CORPORATION · PORTLAND, OR, UNITED STATES · built 2007
Hull materialSteel
PropulsionNone
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTLAND, OR
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 20 May 2026 · expires 30 June 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2442 - Convention (Subpart B), Net Ton
8724 - Dead Weight, Gross Ton
4110 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 42 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ERNEST CAMPBELL Towing Vessel · MISLE 101698 · 25 January 2008 · activity 3137694ROYAL MELBOURNE Towing Vessel · MISLE 204199 · 25 January 2008 · activity 3137694

Inspection history · 42

24 March 2025 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8099525
7 March 2025 Bulk Liquid Transfer Monitor
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8090117
23 September 2024 Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8007990
1 November 2023 Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7802154
18 October 2022 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7580636
24 August 2022 MARPOL Annex I Examination · MARPOL Annex VI Survey · COI Inspection · Drydock Extension
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7540983
12 August 2022 Administrative Inspection · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7563606
28 July 2022 Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7471902
26 October 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7339988
22 December 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7115352
20 July 2020 Deficiency Check · Periodic Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7012332
18 November 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6840396
14 October 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6836049
26 September 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6542692
26 October 2017 Damage Survey · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6296463
14 August 2017 Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6240493
3 January 2017 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6069299
16 September 2015 Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5721322
14 January 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5053436
7 October 2014 Annual Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4999952
17 September 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4985912
27 July 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4935572
15 December 2013 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4769703
11 September 2013 MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4711396
16 August 2013 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4687041
27 June 2013 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4633734
17 November 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4486311
5 September 2012 Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4432804
29 August 2012 Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4426410
29 December 2011 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4215749
28 December 2011 MARPOL Annex I Examination · Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4215165
22 October 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4173599
9 October 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4164370
18 November 2010 Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3894195
6 June 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3759224
14 February 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3679934
25 January 2010 Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3668167
16 January 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3665337
12 January 2009 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3390053
25 January 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3137694
12 December 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3114366
3 December 2007 Construction Oversight · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3099661

Deficiency record · 14

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 September 2024 Resolved
All installations must be of marine type engines suitable for the intended service, designed and constructed in conformance with the requirements of this subchapter. Fuel lines on port cargo pump are chafing and cable are visible. Replace fuel lines. 46 CFR 58.10(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2024
Resolution: Received photogrpahs from vessel rep of replaced fuel lines.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 24 August 2022 Resolved
Each cargo tank of a tank barge must have one of the following liquid overfill protection arrangements. A system meeting the requirements of 46CFR2007. The overfill alarm for the #1 Port Cargo tank is inoperable. Vsl cannont onload cargo cargo in tank until alarm is repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 August 2022
Resolution: Witnessed overfill alarm of tank #1 port, all sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 24 August 2022 Resolved
Each cargo tank of a tank barge must have one of the following liquid overfill protection arrangements. A system meeting the requirements of 46CFR2007. The high level alarm for the #2 Port Cargo tank is inoperable. Vsl cannont onload cargo cargo in tank until alarm is repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 August 2022
Resolution: Witnessed high level alarm of tank #2 port, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 August 2022 Resolved
Every tank vessel subject to the regulations of this subchapter shall be inspected every 5 years or more often, if neccessary by the CG to see that the hull, boilers, machinery equipment. Unable to verify operation of thermal fluid headter due to no competent person onboard available to perform test. Vessel cannot load grade E cargo that requires use of thermal fluid heater.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 October 2022
Resolution: Witnessed satisfactory test of the Thermal Fluid Heater.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 July 2020 Resolved
If the periodic inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the [name withheld] proper operator of the thermal fluid heater prior to use of the thermal fluid heater during cargo operations.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 23 July 2020
Resolution: Rubber bushing replaced in Thermal Fluid pump coupling. Thermal Fluid heater operated sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 July 2020 Resolved
Wire must be in an enclosure. Wire at Three Tank Level Indicators and two thermometer sensor points (out of a total of 12) was abraded through apparently due to wind and vibration. Two of these were electric taped together.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 23 July 2020
Resolution: Damaged wiring removed (alarm wiring remains in place, TLI and temperature sensor wiring removed).
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 July 2020 Resolved
Vapor collection piping must be electrically bonded to the hull and must be electrically continuous. Bonding not evident on VCS piping. Isolation valves installed with "Garlock" type gasket, main VCS header continuous and mounted in vibration cradle mounts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 July 2020
Resolution: VCS piping had "star" washers installed both sides of every connection between tank domes and VCS manifold.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 26 October 2017 Resolved
Prove proper operation of #6 STBD visual overfill indicator. Cargo ops permitted in San Francisco OCMI zone under the following conditions: An assistant PIC is located at #6 STBD and is able relay information to the barge and facility PIC's.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2017
Resolved 1 November 2017
Resolution: Alarms repaired.
Construction/Loadline › Hull › Weld
Issued 16 September 2015 Resolved
Repair crack in #4 cargo tank in way of tank sump.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 October 2015
Resolved 18 September 2015
Resolution: Chipped out, rewelded and NDT.
Deck/Cargo › Cargo Heating › General
Issued 25 January 2010 Resolved
Prove proper operation of thermal fluid heater prior to use to the satisfaction of attending Coast Guard Marine Inspector in accordance with 46 CFR 61.30-20.
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 3 February 2010
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 12 January 2009 Resolved
MH01: Install overspeed device on both generators. Overspeed device must be independent of the normal operating governor and adjusted so that the speed cannot exceed the maximum rated speed by more than 15 percent. 46 CFR 111.12-1(b)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 April 2009
Resolved 20 January 2009
Resolution: Consulted technical representative for Northern Lights. Generator governors are equipped with overspeed protection.
Documentation › Certificates/Documents › IOPP Certificate
Issued 12 January 2009 Resolved
MH02: Have available all original certificates for inspection (Including Certificate of Documentation, IOPP, and Classification Certificate). Vessel is restricted to domestic voyages only.
Action required: 705 - Other - as specified
Resolved 20 January 2009
Resolution: All original documents are onboard vessel.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 December 2007 Resolved
No cargoes identified as NLS may be carried. Correct to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 9 January 2009
Resolution: After talking with [name withheld] (company rep), the barge has not and will not carry any Cat Z NLS listed on the existing CAA. [name withheld] requested they be removed from the CAA. Contacted MSC. MSC issued new CAA without the Cat Z NLS.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 3 December 2007 Resolved
Cargo Hoses have not been hydro tested. Hydro test and provide proof to satisfaction of Cg Inspector prior to cargo operations.
Action required: 705 - Other - as specified
Due 3 January 2008
Resolved 4 December 2007
Resolution: Hydro tested hoses.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.