Records from 2012 to 2025. Most recent: inspection, 29 April 2025.
Documentation record
Registered dimensions (L × B × D)37.0 ft × 12.1 ft × 3.8 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCROSBY LUMBER CO · BAY MINETTE, AL, UNITED STATES · built 1967
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portSAULT STE MARIE, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 16 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
29 April 2025
Administrative Inspection · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8123104
29 October 2024
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8026626
19 March 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8123107
1 November 2023
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7818740
23 October 2023
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7812669
18 October 2023
COI Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7803820
1 February 2023
Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7630274
13 October 2022
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7576419
14 October 2021
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7332095
7 December 2020
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7107376
15 January 2020
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6894982
18 October 2018
Initial Certification · DAPI Audit · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6559532
7 September 2018
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6535024
22 August 2018
Uninspected Other
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6527516
22 March 2017
Industry Initiated Exam · Administration
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6109676
18 September 2014
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4989112
20 May 2014
Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4863178
10 September 2013
Industry Initiated Exam
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4713980
6 June 2013
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4616935
27 September 2012
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4451511
19 July 2012
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4383556
20 April 2012
Type not recorded
No type recorded · Violation Case Coordination Center · Activity 4290995
18 April 2012
Deficiency Check
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4289621
12 April 2012
Type not recorded
No type recorded · Station St Joseph · USCG Great Lakes District (CGD-GL) · Activity 4285681
12 April 2012
Type not recorded
No type recorded · Station St Joseph · USCG Great Lakes District (CGD-GL) · Activity 4285746
12 April 2012
Marine Casualty Follow Up
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4285823
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 November 2023
Resolved
Vessel is currently overdue for hull exam. Vessel is outside the scope of its COI and can not be used under Subchapter M. MCM Marine currently holds a WSE granted by the OCMI and TAMMY may still operate as a workboat within that worksite.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2023
Resolved 2 May 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 October 2023
Resolved
Vessel's horn is inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2023
Resolved 16 November 2023
Resolution: corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 October 2021
Resolved
Found the soft patch has gaps and is in need of sealer or gasket material. Gasket on engine room forward hatch needs new gasket material. These gaps could allow enough oxygen access in the space to render the fixed system ineffective.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 6 July 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 October 2021
Resolved
Life ring just fwd of the pilothouse has reached the end of it's service life and should be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 6 July 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2021
Resolved
Found an old extension cord that has a cigarette plug spliced into it. Remove extension cord and hard wire in an approved electrical port.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 6 July 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 October 2021
Resolved
Aspirin in first aid kit is expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 6 July 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 December 2020
Resolved
Original COI not posted and not located at the completion of inspection. This office can provide a new original COI upon request from the company.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2021
Resolved 19 February 2021
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 December 2020
Resolved
Vessel had no record of fire detection panel and Fireboy servicing for the current year. Have these systems serviced and provide records to the Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2021
Resolved 14 October 2021
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 7 December 2020
Resolved
Liferaft and hydrostatic release are expired. Have liferaft serviced and replace expired hydro.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2021
Resolved 19 February 2021
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 December 2020
Resolved
Alarm to indicate high bilge water level is not functioning from the engine room. Vessel rep believes it is a faulty float switch. Replace necessary equipment to get alarm functioning as it should.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2021
Resolved 19 February 2021
Resolution: Corrected.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 December 2020
Resolved
Vessel had no drills logged since our last visit. Captain stated that they were too busy this year to conduct drills. Get boat underway and conduct drills. Log drills appropriately and marine inspector will observe them.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2021
Resolved 14 October 2021
Resolution: Corrected.