Records from 2007 to 2011. Most recent: inspection, 22 December 2011.
Inspection history · 14
22 December 2011
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4212596
19 December 2011
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4210868
10 December 2011
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4205520
7 January 2011
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3922563
8 December 2010
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3905451
8 January 2010
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3660836
8 December 2009
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3646780
25 April 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3460409
25 April 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3460421
28 March 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3441952
28 March 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3443880
28 March 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3447258
13 October 2008
MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3340733
1 October 2007
MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3069662
Engineering › Lubricating Oil Storage/Transfer System › Gauge
Issued 8 December 2010
Resolved
0750 - Fire Prevention - Main engine lube oil storage tank sight glass valve has a fabricated device designed to lock open the sounding gauge. SOLAS 74a II-2/4
Action required: 705 - Other - as specified
Due 8 December 2010
Resolved 8 December 2010
Resolution: Crew removed the device in the presence of the PSCO, recommend taking considerable notice to these sight glass valves at next inspection as this condition presents a major fire hazard should the sight glass break.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 8 December 2010
Resolved
1720 - Bunker lines haven't been hydrostatically tested, provide prior to bunkering in U.S. - 33CFR155.720
Action required: 705 - Other - as specified
Due 8 December 2010
Resolved 7 January 2011
Resolution: Vessel provided annual pressure test results conducted on December 30, 2010. See documents.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 8 December 2010
Resolved
2055 - Manuals instructions etc. - Master could not provide any oil transfer procedures, provide prior to bunkering in the U.S. - 33CFR155.720
Action required: 705 - Other - as specified
Due 8 December 2010
Resolved 7 January 2011
Resolution: Vessel provided picture of posted oil transfer procedures. See documents.
Electrical › Electric Generation Source (emergency) › Generator
Issued 8 December 2009
Resolved
The vessels emergency source of electrical power is inoperable. The vessel shall submit a Class report attesting to the proper repair and operation of the emergency generator. SOLAS 2004 cons ed., Chpt II-1, Reg 43.1.1
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2009
Resolution: received class report stating that emergency generator was repaired and is now operational
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 8 December 2009
Resolved
The 220V and 440V panels in the control room (engine) show a ground. The vessel shall submit a class report attesting to the repair and operation of the equipment prior to departure. SOLAS 2004 con ed., Chpt II-1, REG 45.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2009
Resolution: received class report stating that repairs have been made to ship''s electrical system; readings and 220V and 440V control panels are acceptable
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 December 2009
Resolved
Steering Gear room does not have adequate nonslip surface to ensure suitable working condition. The vessel shall ensure arrangements in the steering gear room include grates or other nonslip surface. Prior to next US port after sailing foreign. SOLAS con ed. 2004., Chpt II-1, Reg 29.13.2
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 8 January 2010
Resolution: Vessel submitted documentation and photos attesting to the installation of a non slip surface in the steering gear space.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 8 December 2009
Resolved
The vessel does not have a "Discharge of Oil Prohibited" placard displayed. The vessel shall display such placard prior to next US port after sailing foreign. 33CFR155.450
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 8 January 2010
Resolution: Vessel submitted documentation attesting to the installation of the "Discharge of Oil Prohibited" placard.
Construction/Loadline › Hull › Hull Plating
Issued 28 March 2009
Resolved
Vessel was involved in a collision with a barge; hit the stbd side fwd breakwater plate.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2009
Resolved 31 March 2009
Resolution: Received class report from GL rectifying deficiency.