Records from 2009 to 2025. Most recent: inspection, 28 July 2025.
Documentation record
Registered dimensions (L × B × D)70.0 ft × 28.0 ft × 9.0 ft
Registered tonnagegross 118 / net 94
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRODRIGUEZ BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portEVANSVILLE, IN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 November 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Simplified, Net Ton
118 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
28 July 2025
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8191731
2 March 2025
Damage Survey · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8087165
27 February 2025
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8096828
24 May 2024
Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7918669
13 May 2024
TPO Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7909964
2 August 2023
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7758935
1 August 2023
Damage Survey · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7758936
22 February 2023
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7640929
27 July 2022
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7518380
24 March 2021
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7162295
8 January 2021
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7121606
4 May 2020
Initial Certification · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6973011
7 January 2020
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6895636
14 August 2019
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6785243
28 May 2019
TPO Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6702196
6 December 2017
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6322907
16 November 2015
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5766558
4 August 2015
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5214549
8 December 2013
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4770556
8 November 2012
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4480740
24 October 2012
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4474205
13 March 2012
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4269375
27 March 2011
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3975649
30 January 2010
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3673285
30 January 2010
Marine Casualty Follow Up
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3675465
25 January 2010
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3680439
21 August 2009
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3575207
15 January 2009
Administration · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3394495
15 January 2009
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3395443
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 July 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Electronic throttle controls are not engaging vessel reduction gears. Diagnose throttle issue and test to the satisfaction of an attending Marine Inspector. The vessels TPO has the option to clear this deficiency with notification to the local OCMI within 72-hours in accordance with CG-CVC Policy Letter 17-10.
46 CFR 143.205(a)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 July 2025
Resolution: TPO Close out letter received
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation. Vessels STBD propeller is fouled with a log. Make permanent repairs to ensure vessel is fully functional, the satisfaction of attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2025
Resolved 11 March 2025
Resolution: Log removed. TPO letter uploaded.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 May 2024
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Vessels bilges have approximately 12 inches of oily water.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 May 2024
Resolution: Attended vessel at Walker Boatyard. Bilge was free from oil accumulation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2024
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Vessels port generator has an excessive oil leak on the prime mover.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 May 2024
Resolution: Ran port generator, oil leak was contained.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 13 May 2024
Resolved
The vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by either the OCMI, or TPO engaged to perform an audit or survey. Vessels port stern void is taking on water.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 May 2024
Resolution: Rudder bushings were repaired to prevent the vessel from taking on water. Entered the port aft void to examine welds, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2024
Resolved
(a) Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
(b) The crew of each towing vessel must demonstrate the ability to operate the primary and auxiliary machinery and electrical systems for which they are responsible, and to do so under normal and emergency conditions. This includes, but is not limited to, responses to alarms and restoration of
propulsion and steering in the event of failure.
(c) Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must:
(1) Be maintained to ensure proper operation;
Both port and starboard shaft packings glands leaking excessive. Tighten packing glands to proper amount of water lubricating indication.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2024
Resolution: Shoreside maintenance personnel tightened packing glands to reasonable amount of leaking for lubrication indication.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 May 2024
Resolved
Fire extinguisher near bottom of Engine Room steps missing seal and handle is bent. Replace with serviceable extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 13 May 2024
Resolution: Extinguisher replaced during the course of the audit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2024
Resolved
Port lifebuoy light has been activated and disconnected from buoy. Install proper light and re-attach line to buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 13 May 2024
Resolution: Light has been replaced and lanyard re-attached to buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2024
Resolved
Several onboard lifejackets had expired lights; inspect and replace lights as needed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 13 May 2024
Resolution: All onboard lifejackets inspected and lights replaced as required.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 13 May 2024
Resolved
Broken welds on aft deck grating support; make permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 3 June 2024
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 1 August 2023
Resolved
Each towing vessel must have a reliable means to provide notification when an essential system develops problems that require attention. Low hydraulic steering fluid level is one of these essential systems. Prove proper operation of your installed Low hydraulic steering fluid level alarm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2023
Resolved 7 August 2023
Resolution: Replaced alarm switch