MAURY USCG vessel records Sign in
← All vessels

LADY CYNTHIA JANE

LADY CYNTHIA JANE is a 2008 offshore supply vessel. The Coast Guard has recorded 10 inspections since 2007, most recently in September 2025, along with 19 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 2007 to 2025. Most recent: inspection, 8 September 2025.

Built
2008
Last inspected
8 September 2025
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9418511 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH4118
931773
Flag
UNITED STATES
338249000
Maury page id
psix-931773

Inspections, by type

…with no type recorded1
Years with a record 9 calendar years (2007–2025)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)203.1 ft × 46.0 ft × 17.0 ft
Registered tonnagegross 1,313 / net 481
ITC dimensions (L × B × D)Not recorded
ITC tonnagegross 1,313 / net 481
BuilderQUALITY SHIPYARDS LLC · HOUMA, LA, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationCase Pending · issued 10 January 2008
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1313 - Convention (Subpart B), Gross Ton
481 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK9465MMSI 338249000 · active · compulsorily equipped · granted 9 July 2019, expires 9 July 2029 · licensed under a name not among this hull’s recorded names (not shown)
WDH4118MMSI 366560000 · expired · compulsorily equipped · granted 8 April 2014, cancelled 8 June 2024 · licensed under a name not among this hull’s recorded names (not shown)
WDE9876MMSI 368490000 · expired · compulsorily equipped · granted 18 August 2009, cancelled 19 October 2019 · licensed under a name not among this hull’s recorded names (not shown)
WDE2499MMSI 366636000 · expired · compulsorily equipped · granted 8 December 2007, cancelled 10 February 2018 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PACIFIC Industrial Vessel · MISLE 47108 · 4 January 2019 · activity 6609074WILKIN A FALGOUT Towing Vessel · MISLE 106896 · 4 January 2019 · activity 6609074

Inspection history · 10

8 September 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8229854
13 February 2020 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6908543
22 October 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6851797
4 January 2019 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6609074
30 March 2018 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6381745
25 January 2017 ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6068889
14 March 2016 MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5832690
10 March 2009 Annual Inspection
Physical examination · Activities Europe · Activity 3523593
28 January 2008 ACP COI Oversight · Initial Certification · Initial Construction-Excluding Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3137471
26 November 2007 Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3104701

Deficiency record · 19

Lifesaving › Inflatable Liferafts › Servicing
Issued 25 January 2017 Resolved
All, 04, 25 man liferaft servicing is expired. serice or replace all liferafts on board to satisfaction of attending USCG MI or ABS Surveyor. 46 CFR 133.105
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Lifesaving › Lifebuoys › Serviceable
Issued 25 January 2017 Resolved
Marine Inspectors found several ring life bouys with wated plugs. In addition, several ring bouys were found with wasted line, insufficient retro tape. Repair/replace to the satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 133.70
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Turbocharger
Issued 25 January 2017 Resolved
Marine Inspector found oil leak on Starboard main engine near turbo charger. Clean and repair leak to the satisfaction of attending USCG MI or ABS Surveyor. 46 CFR 126.150(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 25 January 2017 Resolved
During testing of #1 Generator, Marine Inspectors found leaking valve covers and exhaust leak. Make repairs to satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 126.150(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 25 January 2017 Resolved
Marine Inspectors identified a "ground fault" on both main engines. Identify ground fault and make repairs to the satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 111.60
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 25 January 2017 Resolved
During testing of the emergency generator, Marine Inspectors observed only 01 means of start (battery). Ensure a second means of starting is available and tested to the satisfaction of USCG Marine Inspectors or ABS Surveyor. SOLAS 74(14)44.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 January 2017 Resolved
During the testing of seft closing fire doors, door from crew mess to galley would not close completely and showed evidence of "tie backs." Adjust and retest to the satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 127.220, 46 CFR 72.05-10
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 25 January 2017 Resolved
Guages on both air receivers are maxed out at 300 psi. MAWP is 300 psi. Relief valves are set at 250 psi, gauges are required to be at 1.2 -2.0 times the setting of the relief valve. Replace to the satisfaction of USCG Marine Inspector or ABS Surveyor. 46 CFR 54.15-5 (f)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 25 January 2017 Resolved
Several deck cargo piping and freshwater butterfly vavle handles wasted. In addition, several support brackets are wasted. Repair/replace to the satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 126.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 January 2017 Resolved
Alcohol testing strips are expired. Place valid ones on board per company DAPI. 46 CFR 4.06-15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 10 February 2017
Resolution: Recieved evidence that DOT approvied alcohol testing strips had been place on board.
Fire Fighting › Fire Pumps › Pressure
Issued 25 January 2017 Resolved
During testing of emergency fire pump, Marine Inspectors noted gauge was inoperable on the bridge. Repair to the satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 130.430
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 25 January 2017 Resolved
Distribution panel P3 have breakers installed that do not match index. Ensure overcurrent protection is to the satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 129.330, 46 CFR 111.40
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 January 2017 Resolved
Marine Inspectors saw no visible egress sinage or IMO symbols in the tank farm, most notably in a dead end cooridor. Place appropriate symbols ot the satisfaction of the attending USCG Marine Inspector or ABS Surveyor. 46 CFR 127.240(b)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 January 2017 Resolved
During testing of the oily water sepperator, crew unable to prove proper testing of the 15ppm alarm. Vessel has no instructions for proper testing of OWS. Produce testing procedures and prove proper operation to the satisfaction of attending USCG Marine Inspector or ABS Surveyor. MARPOL Annex I reg 16 - PRIOR TO USE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 25 January 2017 Resolved
Marine Inspectors found missing dryer vent on crew laundry 01 deck. repair to satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 126.100 -PRIOR TO USE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Operations/Management › Drills/Instruction › Not Conducted
Issued 25 January 2017 No resolution recorded
Vessel must conduct fire, abandon ship, person in the water drills, prior to getting underway, and to the satisfaction of attending CG Marine Inspector. 46CFR 131.535, 46 CFR 133.135, 46 CFR 131.530 Prior To Sail
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Navigation › Piloting/Steering › Compass Deviation Table
Issued 10 March 2009 Resolved
Provide proof of an onboard updated Deviation card for the magnetic compass. Report cleared via E-mail dated 7 May, Item remains open until cleared by attending Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 June 2010
Resolved 28 May 2010
Resolution: cleared during annual inspection
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 10 March 2009 Resolved
Make permanent repairs to the 01 deck, STBD side paint locker lower hinge found with fractured weld. Report cleared via E-mail dated 12 May, Item remains open until cleared by attending Marine Inspector.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 3 June 2010
Resolved 28 May 2010
Resolution: cleared during annual inspection
Lifesaving › Rescue Boat › Construction
Issued 10 March 2009 Resolved
Proved proof of the Rescue boat davit, winch, and release mechanism has been serviced annually as per N.V.I.C. 04-07. Report cleared via E-mail dated 01 May, Item remains open until cleared by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 3 June 2010
Resolved 28 May 2010
Resolution: cleared during annual inspection.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.