Records from 2007 to 2026. Most recent: inspection, 21 January 2026.
Documentation record
Registered dimensions (L × B × D)334.0 ft × 70.0 ft × 25.0 ft
Registered tonnagegross 5,706 / net 5,706
ITC dimensions (L × B × D)334.0 ft × 70.0 ft × 25.0 ft
ITC tonnagegross 4,887 / net 2,616
BuilderBOLLINGER GRETNA LLC · HARVEY, LA, UNITED STATES · built 2008
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 July 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5706 - Regulatory (Subpart C or D), Gross Ton
4887 - Convention (Subpart B), Gross Ton
5706 - Regulatory (Subpart C or D), Net Ton
2616 - Convention (Subpart B), Net Ton
9639 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 34
21 January 2026
Administrative Inspection · Annual Inspection · MSP Select Additional Oversight – Risk Assessment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8299285
13 January 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8062560
19 October 2023
MTSA/ISPS Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7811070
10 October 2023
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7805790
16 June 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7479200
18 May 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7199883
16 February 2021
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7138785
2 December 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7105112
7 August 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7026686
30 July 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7020455
14 February 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6908946
15 July 2019
Deficiency Check · Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6750824
26 March 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6649228
23 July 2018
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6488239
5 July 2018
Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6467911
24 January 2018
COI Inspection · MARPOL Annex I Examination · MARPOL Annex II Examination · MTSA Verification · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6342595
13 December 2017
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6323605
18 January 2017
Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6072567
11 April 2016
Drydock Exam · Periodic Inspection · Internal Structural Exam · MTSA Verification · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5851191
1 September 2015
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5232928
24 March 2015
MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5089828
13 June 2014
Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4886698
5 June 2013
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4612174
29 December 2012
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4509511
3 December 2012
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4495184
16 November 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4486839
24 August 2012
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4420677
11 January 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4224227
15 October 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4169544
1 July 2011
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4064210
21 June 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4052291
20 July 2010
Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3800951
17 June 2009
MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3504741
31 October 2007
MTSA Verification · COI Inspection · Administrative Inspection · Internal Structural Exam · MARPOL Annex I Examination · Cargo Tank Internal · Initial Construction-Excluding Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3090552
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 December 2023
Resolved
If the Coast Guard determines that the plan meets all requirements of this subpart, the Coast Guard will notify the vessel owner or operator with an approval letter ... Vessel did not have a copy of Coast Guard approval letter for their Vessel Response Plan.
33 CFR 155.1065 (c)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 5 December 2023
Resolution: VRP approved by Coast Guard.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 5 December 2023
Resolved
Where cargo pump shafts pierce gastight bulkheads, stuffing boxes with readily accessible gastight glands shall be provided ... Vapor boot on outboard cargo pump was not gastight, visible light can be seen from inside cargo pump room. Make effective repairs in accordance with manufactures specifications prior to cargo operations.
46 CFR 32.50-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 December 2023
Resolution: Received photos of the new vapor boot.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 5 December 2023
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapors, gases or liquids whose temperature exceeds 150 OF.' shall be suitably insulated where necessary to preclude injury to personnel ... Out board generator was missing exhaust manifold lagging. Make effective repairs to the satisfaction of the attending marine inspector.
46 CFR 56.50-1 (k)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2023
Resolved 8 December 2023
Resolution: Lagging was installed on the exposed turbocharger. All sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 5 December 2023
Resolved
Each hose assembly used for transferring oil or hazardous material must meet the following requirements:
(e) Each hose must be marked with one of the following:
(2) For oil products, the words "OIL SERVICE" ... Cargo
hoses were not labeled with "OIL SERVICE". Make
corrections to meet hose assembly requirements to the satisfaction of the attending marine inspector.
33 CFR 154.500 (e) (2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2023
Resolved 8 December 2023
Resolution: Appropriate hoses were marked with "OIL SERVICE ONLY".
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 May 2021
Resolved
Vessel has an invalid COI.
Certificates of Inspection will be issued for a period of 5 years; COI expires on 23APR2023. Vessel missed annual, DDX, ISE and PV exam.
Complete COI Inspection prior to conducting cargo operations.
Action required: 705 - Other - as specified
Due 18 September 2024
Resolved 23 June 2022
Resolution: COI has been deactivated.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 22 July 2019
Resolved
Relief valves for the pressure vessel and #2 air compressor are not operating properly. Repair or replace and prove to the satisfaction of the attending CG marine inspector prior to operating cargo pumps.
Action required: 705 - Other - as specified
Resolved 26 July 2019
Resolution: A new relief valve was installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 July 2019
Resolved
Port navigation running light is not working properly. Make repairs and prove proper operation to attending CG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 9 August 2019
Resolution: Verified operation of port navigation light.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 22 July 2019
Resolved
Bergen tank level monitoring system in ship's office has an inverter fault and is improperly connected. Make repairs and prove to the satisfaction of attending CG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 9 August 2019
Resolution: Verified electrician made repairs.
Construction/Loadline › Penetrations › Gasket
Issued 24 January 2018
Resolved
Gasket on #4S Void aft hatch is not continuous
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 30 January 2018
Resolution: Gasket was replaced with new.
Construction/Loadline › Markings › Fresh Water Load Line
Issued 24 January 2018
Resolved
Fresh water mark on load line is not permanently marked.
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 30 January 2018
Resolution: Mark was punched and repainted
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 December 2017
Resolved
Vessel did not have current drug and alcohol enrollment certificate.
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 14 December 2017
Resolution: Recieved copy of the certificate. Certificate was at the company's office, and never made it onboard. Def cleared.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 January 2017
Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under §67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. The original COD was not onboard the vessel. 46 CFR 67.7
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 January 2017
Resolution: Received and accepted certified copy of COD.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 24 March 2015
Resolved
There must be ground detection for each power distribution system that is isolated from the ship's service power system by transformers, motor generator sets, or other devices. The vessel has the wrong ground detection system installed on the 120V system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 April 2015
Resolved 30 March 2015
Resolution: Received technician report from General Marine Electric stating the correct 120v ground detection has been installed.
Construction/Loadline › Markings › Load Line Mark
Issued 24 March 2015
Resolved
The International Load Line Certificate shall not be issued to the ship until the surveyor has certified the marks are correctly and permanently indicated on the ship's sides. The load line on the ship's hull does not match the Load Line Certificate.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2015
Resolved 2 April 2015
Resolution: Vessel has fixed their load line on the hull. It now properly reflects what is listed on the certificate.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 24 March 2015
Resolved
A pressure gauge shall be installed for each pump discharge, and it shall be located at a point visible with respect to the pump controls. The cargo pump gauge cannot be seen from the operating station. Due prior to next credit drydock in 2018.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 March 2018
Resolved 21 April 2015
Resolution: Verified that the cargo pump gauges are now visible from the operating station.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 24 August 2012
Resolved
Both gen sets are oil covered at the front end including the cooling fan; must clean and remove all oil residue to prevent possible pollution and fire hazard.
Due 7 September 2012
Resolved 7 September 2012
Resolution: Cleaned Gen sets and submitted picture
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 15 June 2009
Resolved
Vsl needs to prove full compliance to MARPOL Annex VI regulations to the satisfaction of the attending [name withheld] is limited to domestic voyages only until compliance is proven.
Action required: 705 - Other - as specified
Resolved 31 July 2009
Resolution: Received documentation to fulfill requirements of the 835 issued. Deficiency cleared.