Records from 2008 to 2024. Most recent: inspection, 2 October 2024.
Inspection history · 22
2 October 2024
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8013141
2 November 2021
COI Inspection · MTSA Verification · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7335850
6 July 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7247407
23 April 2021
Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7178656
6 May 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6949064
1 April 2019
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6653907
29 January 2018
Cargo Tank Internal · COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6350232
30 March 2017
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6114630
10 March 2016
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5838187
11 February 2016
Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5813781
20 March 2015
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5088706
4 March 2015
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5078405
4 March 2014
Administrative Inspection · Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4809994
26 August 2012
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4423609
26 August 2012
Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4423720
12 March 2012
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4259174
2 March 2010
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3688632
19 January 2010
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3665918
6 January 2010
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3659702
27 April 2009
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3462269
24 November 2008
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3368661
3 March 2008
Cargo Tank Internal · Hull Examination · MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3157331
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 17 February 2016
Resolved
Prove repair of tank high level alarm junction box. One hinge and one latch are broken, rendering box non-watertight.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 10 March 2016
Resolution: Received photos verifying repair of junction box.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 4 March 2014
Resolved
Pressure/vacuum gauge on vapor header line was stuck reading 3 psi. Gauge was removed to verify that it was inoperable. Pressure reading remained even with gauge removed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2014
Resolved 13 March 2014
Resolution: Received verification that vapor pressure/vacuum gauge had been replaced.