Records from 2007 to 2026. Most recent: inspection, 4 April 2026.
Inspection history · 23
4 April 2026
COC-CHEM Annual · Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8343470
13 April 2025
PSC B · Administrative Inspection · COC-CHEM & TVE Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8110723
21 December 2023
Damage Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7841500
4 March 2023
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7645362
22 September 2021
PSC B · COC-CHEM Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7318187
26 October 2019
ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6842538
27 March 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6650371
25 March 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6648539
5 March 2019
COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6636851
25 June 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6644789
2 February 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6348472
30 December 2017
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6330517
27 August 2015
Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5222563
15 March 2014
ISPS II Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4813454
20 July 2011
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4088091
11 July 2011
COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4077372
9 October 2008
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 3341367
9 October 2008
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3341609
23 September 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3331226
7 April 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3179146
5 April 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3178004
4 January 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3124874
30 December 2007
COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3122491
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 5 March 2019
Resolved
AFTER ANY SURVEY OF SHIP UNDER REG. 7,8,9 OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION.
DURING INSPECTION FOUND ELECTRONIC WORKSHOP BEHIND SWITCHBOARD IN THE ECR THAT IS NOT ON THE FIRE CONTROL PLAN.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 March 2019
Resolved 27 March 2019
Resolution: Received class LR report attesting to the verification of the fire control plan and removal of the table in the ECR.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 March 2019
Resolved
THE LIFERAFT PAINTER SYSTEM SHALL PROVIDE A CONNECTION BETWEEN THE SHIP AND THE LIFERAFT AND SHALL BE ARRANGED AS TO ENSURE THAT THE LIFERAFT WHEN RELEASED, IS NOT DRAGGED UNDER BY THE SHIP.
DURING INSPECTION BOTH PORT AND STARBOARD LIFERAFT PAINTER SYSTEM ATTACHED INCORRECTLY.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 6 March 2019
Resolved 6 March 2019
Resolution: LIFE RAFT PAINTER SYSTEM PROPERLY ARRANGED PRIOR TO ISPECTION COMPLETION.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 March 2019
Resolved
NOT LESS THAN 12 ROCKET PARACHUTE FLARES, COMPLYING WITH 3.1 OF THE CODE SHALL BE CARRIED AND STOWED ON OR NEAR THE NAV. BRIDGE.
DURING INSPECITON IT WAS FOUND THAT 06 FLARES ON THE BRIDGE WERE EXPIRED.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2019
Resolved 25 March 2019
Resolution: Accepted delivery note that flares were delivered to vessel.