MAURY USCG vessel records Sign in
← All vessels

ALORA

ALORA is a 2007 tank ship. The Coast Guard has recorded 19 inspections since 2008, most recently in July 2024, along with 12 deficiencies and 4 operational controls.

Records from 2008 to 2024. Most recent: inspection, 21 July 2024.

Built
2007
Last inspected
21 July 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9374856 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V8651
936109
Flag
SINGAPORE
—
Maury page id
psix-936109

Inspections, by type

…with no type recorded3
Years with a record 8 calendar years (2008–2024)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it42010 - Convention (Subpart B), Gross Ton
73604 - Dead Weight, Metric Ton
89321 - Displacement, Metric Ton
22454 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

M.A.R.S. LIBERTY Towing Vessel · MISLE 186637 · 4 July 2018 · activity 6821195JUPITER Towing Vessel · MISLE 345587 · 4 July 2018 · activity 6821195OKINAWA Freight Ship · MISLE 997018 · 4 July 2018 · activity 6821195I-150B Freight Barge · MISLE 1594473 · 4 July 2018 · activity 6821195

Inspection history · 19

21 July 2024 PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7963106
18 July 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7961027
7 August 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7762470
15 March 2023 COC-TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7651226
21 December 2021 COC-TVE Annual · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7369308
9 October 2020 Ballast Water Examination · COC-TVE Renew · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7073432
4 July 2018 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6473649
4 July 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6821195
29 May 2018 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6427717
14 May 2018 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6412054
7 May 2018 ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6405021
22 August 2016 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5979528
29 July 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3549595
13 March 2009 COE-Dockside
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3432934
18 February 2009 PII Safety Exam · COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3420021
20 June 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3242386
15 June 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3237710
25 February 2008 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3152963
15 January 2008 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3130590

Deficiency record · 12

Lifesaving › Lifeboat › Hatches
Issued 14 May 2018 Resolved
0630, Maintenance and inspection of life-saving appliances shall be carried out in a manner having due regard to ensure reliability of such appliances. Port lifeboat; PSCO found the handle broken and missing on the inside of the of the side door (aft upper handle). 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 29 May 2018
Resolution: Cleared based on ABS Class Report Number FL3503281 dated 26 May 2018.
Lifesaving › Launching Appliances › Davit
Issued 14 May 2018 Resolved
0630 Maintenance and inspection of life-saving appliances shall be carried out in a manner having due regard to ensure reliability of such appliances. PSCO found three carter pins in the starboard boat davit wire cable end connectors that had been replace by construction nails. 10 ac
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 May 2018
Resolved 16 May 2018
Resolution: Correct carter pins installed.
Lifesaving › Launching Appliances › Falls
Issued 14 May 2018 Resolved
0630 Maintenance and inspection of life-saving appliances shall be carried out in a manner having due regard to ensure reliability of such appliances. PSCO found prot davit (forward) wire cable end connector pin had be replace by construction nail. 17 a, (b or c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 May 2018
Resolved 15 May 2018
Resolution: Flag State Surveyor witnessed installation of correc carter pin.
Documentation › Manuals/Policy Documentation › Procedures and Arrangements Manual (NLS)
Issued 7 May 2018 Resolved
1911 - P&A Manual - The main purpose of the manual is to identify for the shops officers the physical arrangements and all the operational procedures with respect to cargo handling and tank cleaning. Vessel is authorized to carry certain Category Y cargoes as stated on vessel's Certificate of Fitness. P&A Manual approved by ABS on 12MAR07 does not address cleaning and disposal procedures for Cat Y cargoes. Deficiency must be cleared prior to loading any Cat Y cargoes as defined in current Certificate of Fitness. MARPOL (2011) Annex II/14.2 ac
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2018
Resolution: Received proper class stamped amendments to the P&A Manual addressing cleaning procedures for Y cargoes.
Lifesaving › Launching Appliances › Davit
Issued 7 May 2018 Resolved
0635 - Launching Arrangement for Rescue Boats - Each lifeboat shall be provided with an appliance which is capable of launching and recovering the lifeboat. Port lifeboat(rescue boat) is unable to be recovered by the davit to the final secured position. When davit begins transition inboard, the securing hook will not lock into place. 74 SOLAS (2014) III/16.2 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2018
Resolved 14 May 2018
Resolution: ABS Surveyor and PSCO witnessed proper operation davit.
Lifesaving › Launching Appliances › Davit
Issued 7 May 2018 Resolved
0635 - Launching Arrangements for Rescue Boats - Falls used in launching shall be inspected periodically with special regard for areas passing through sheaves. Port rescue boat davit forward arm, the forward sheave is frozen in place and does not rotate as the fall passes by. 74 SOLAS (2014) III/20.4 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2018
Resolved 14 May 2018
Resolution: ABS Surveyor and PSCO witnessed proper operation of the davit and sheaves.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 22 August 2016 Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATION 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY. WITHOUT THE SANCTION OF THE ADMINISTRATION. INCINERATOR DOORS ARE DAMAGED BEYOND SAFE OPERATION. BOTTOM DOOR HAS BEEN MODIFIED WITHOUT CLASS APPROVAL.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 May 2018
Resolution: Verified during exam all in working order.
Engineering › Feedwater/Condensate Water System › Tank
Issued 22 August 2016 Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATION 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY. WITHOUT THE SANCTION OF THE ADMINISTRATION. WATER COLLECTION HOSE WAS ADDED TO BOILER CASCADE TANK WITHOUT CLASS APPROVAL.
Due 22 September 2016
Resolved 7 May 2018
Resolution: Verified hose was removed during exam.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 22 August 2016 Resolved
THE INERT GAS SYSTEM SHALL BE CAPABLE OF INERTING, PURGING, AND GAS-FREEING EMPTY TANKS AND MAINTAINING THE ATMOSPHERE IN CARGO TANKS WITH THE REQUIRED OXYGEN CONTENT. DUE TO FLAME SENSOR FAILURE, GAS GENERATOR PORTION OF SUPPLY WAS UNABLE TO START (FLUE-GAS PORTION IS WOKRING PROPERLY).
Due 22 September 2016
Resolved 7 May 2018
Resolution: IGG has been removed from service.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (air motor)
Issued 20 June 2008 Resolved
Vessel granted deviation from the rules to enter COPT New Orleans with inop Main Engine control from bridge.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2008
Resolved 20 June 2008
Resolution: Received documentation satisfying requirements.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 15 January 2008 Resolved
certificate does not indicate if exemptions were or were not granted
Action required: 705 - Other - as specified
Due 15 February 2008
Resolved 25 February 2008
Resolution: Received a new Safety Construction Certificate issued by American Bureau of Shipping, on 06-Feb-2008. An exemption has not been issued.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 January 2008 Resolved
emergency lighting failed to operate when tested
Due 15 February 2008
Resolved 15 January 2008
Resolution: crew replaced bulbs prior to coast guard departure

Ownership record