Records from 2009 to 2024. Most recent: inspection, 15 July 2024.
Inspection history · 10
15 July 2024
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7946525
16 December 2020
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7103141
30 November 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7103704
5 July 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6467279
4 July 2018
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6466928
4 July 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6821195
18 June 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6393933
10 March 2016
ISPS II Exam · Ballast Water Examination · Deficiency Check · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5825841
25 March 2014
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4817817
3 March 2009
PII Safety Exam · Deficiency Check · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3421877
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 July 2018
Resolved
01-1400-The condition of the ships and its equipment shall be maintained...fit to proceed to sea...on board. Vsl involved in a allision which caused damage to the port side. PSCOs observed a 40 cm crack in way of the port bow. Submit for review a class report attesting to the damage found during the survey and that authorized temporary or permanent repairs have been completed and the vessel is fit for sea. 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 5 July 2018
Resolved 6 July 2018
Resolution: Received Class Report attesting to satisfactory repairs.
Engineering › Fuel Oil Service System › Piping
Issued 18 June 2018
Resolved
0750-Fire Prevention-Means shall be provided to control leaks of flammable liquids. PSCO's observed excessive FO leaking IWO: FO filter valve approximately 7 cm of FO in temporary containment, 1-3 FO purifires, FO strainer, circulation pumps packing glands with temporary containment, and unidentified source leaking on deck outside containment IWO FO strainer. SOLAS 74a 2009 Cons. II-2/4.1 60A
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Recieved, reviewed and accepted class report from DNV-GL stating the deficiency was rectified. class report stated: repaired gaskets,valvles, flanges,and tested under pressure to the satisfaction of class.
Engineering › Fuel Oil Service System › Piping
Issued 18 June 2018
Resolved
0750-Fire Prevention-Means shall be provided to control leaks of flammable liquids. PSCO observed FO leaking IWO MDE #1 FO injectors. SOLAS 74A 2009 Cons. II-2/4.1 60A
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Recieved, reviewed and accepted class report from DNV-GL stating the deficiency was rectified. class report stated: replace o-rings and tested under pressure to the satisfaction of class.
Construction/Loadline › Hull › Hull Plating
Issued 18 June 2018
Resolved
9900-Other(not clearly hazardous)- The master, owner, operator or person in charge of any vessel equipped with ballast water tanks the operates in the waters of the united states must remove fouling organisms from the vessels hull on a reqular basis and dispose of any removed substance in accordance with local, State and Federal requlations. PSCO observed excessive growth of fouling organisms IWO 1 meter band of barnacles and algea around hull of vessel. Provide documentation from certificate issuing authority attesting to the removal of bio-fouling organisms. 33CFR151.2050(f) 40A
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 November 2020
Resolution: Rcvd Class report indicating vessel is free of sediment and living organisms following a dry dock survey conducted on 07APR19 and applied anti foulant coating.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 18 June 2018
Resolved
0714- Detection- The function of fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the Administration. PSCO observed crew testing flame detector with controlled burn of paper. Vessel does not have appropriate means of testing. SOLAS 74a 2009 Cons. II-2/7.3 40A
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 November 2020
Resolution: Rcvd corrective action plan from company stating an approved flame detector tester was purchased after exam as well as photographs of crew using flame detector tester.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 10 March 2016
Resolved
EXCESSIVE FUEL LEAKS FROM THE SEAL BETWEEN HIGH-PRESSURE FUEL LINES AND INJECTOR ON PISTONS # 2,4, AND 5. PRIOR TO MOVEMENT.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 10 March 2016
Resolved 11 March 2016
Resolution: Received class report from DNV-GL attesting to repairs and satisfactory operation of the main engine.
Lifesaving › Liferaft Equipment › Food Ration
Issued 10 March 2016
Resolved
PSCO OBSERVED 10 STBD LIFEBOAT FOOD RATIONS AND 17 PORT LIFEBOAT RATIONS WERE NOT IN AIRTIGHT PACKAGING
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2016
Resolved 12 March 2016
Resolution: Received proper documentation stating that 27 food rations were ordered and delivered to the vessel.
Fire Fighting › Fire Main › Pressure
Issued 3 March 2009
Resolved
The vessel was unable to produce adequate pressure during a test of the main and emergency fire pump due to frozen lines in the fire main. This poses a risk to the crew in the event of a fire onboard the ship while underway. SOLAS 04 cons. II-2/10.2.2.4.1 [17c]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2009
Resolution: Witnessed satisfactory operational test of main and emergency fire pumps with adequate pressure.