Records from 2008 to 2026. Most recent: inspection, 10 March 2026.
Inspection history · 25
10 March 2026
COI Inspection · Internal Structural Exam · Vessel Attendance · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8318690
5 March 2025
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8077992
24 July 2024
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7966897
28 February 2024
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7860708
21 February 2023
Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7680146
19 October 2022
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7580546
18 October 2022
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7580287
2 March 2022
Annual Inspection · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7422885
15 April 2021
COI Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7176642
24 February 2021
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7145369
25 February 2020
Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6916338
25 February 2019
Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6637084
7 September 2018
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6535002
5 March 2018
Hull Examination · Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6370383
1 November 2017
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6303271
8 June 2017
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6169215
6 March 2017
Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6099779
29 February 2016
Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5836029
14 June 2014
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4892143
9 March 2010
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3697967
3 March 2010
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3689304
19 March 2009
Annual Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3438487
19 February 2009
Administrative Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3424184
24 March 2008
Deficiency Check · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3170358
28 January 2008
Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3130079
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 March 2025
Resolved
The minimum number of portable fire extinguishers required on a vessel must not be fewer than the minimum number required by table 1 to § 181.500(b) and other provisions of this section. The forward required extinguisher is undercharged.
Action required: 10 - Deficiency Rectified
Resolved 5 March 2025
Resolution: replaced during inspection.
Construction/Loadline › Hull › Weld
Issued 29 February 2016
Resolved
Vessel's forward/stbd wheel well was found to have damage where the bow steel plating is welded to the forward wheel well plating. Issued CG-835 requirement to grind out and re-weld damaged area.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 1 March 2016
Resolution: Weld repairs were made to the damaged area and tested.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 28 January 2008
Resolved
Mark vsl name on all required type 1 PFD's as per 46 C.F.R. 185.604
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2008
Resolution: Corrected
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 28 January 2008
Resolved
Place on board required number of adult and child sized type 1 PFD's as per 46 C.F.R. 180.71
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2008
Resolution: Corrected
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 January 2008
Resolved
Conduct all required drills with master and crew as per 46 C.F.R. 185.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2008
Resolution: Corrected
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 28 January 2008
Resolved
Make available for testing the side curtain release system equired by NVCI 01-01
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2008
Resolution: Corrected
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 28 January 2008
Resolved
Mark vsl name and homport on hull as per 46 C.F.R. 67.123
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2008
Resolution: Corrected