LIBERTA is a 2007 public freight. The Coast Guard has recorded 10 inspections since 2017, most recently in January 2019, along with 12 deficiencies and 3 operational controls.
Records from 2017 to 2019. Most recent: inspection, 24 January 2019.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it9556 - Convention (Subpart B), Gross Ton 4378 - Convention (Subpart B), Net Ton 13446 - Dead Weight, Metric Ton 17971 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
1730 Any ship of 400 gross tonnage and above but less than 10000 gross tonnage shall be fitted with oil filtering equipment. Oil water separator is inoperable. MARPOL(2011 CONS.) I/14.1 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2019
Resolution: OWS overhauled and tested in the presence of DNV-GL
1730 Oil filtering equipment shall be of a design approved by the administration and shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15ppm. filtering media not changed in accordance with manufacture's instructions 1-2 years. MARPOL(2011 CONS.)I/14.6 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2019
Resolution: OWS overhauled and tested in the presence of DNV-GL
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 4 January 2019Resolved
Personal Equipment shall consist of protective clothing to protect the skin from the heat radiating from the fire and from burns and scalding by steam. the outer surface shall be water resistant. PSCO observed fire fighter with gloves that were not fire resistant, also with exposed skin on face from improper hood protection. 74 solas(2014) II-2/10.1.1 FSS code ch.3 2.1.1 16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2019
Resolved 5 January 2019
Resolution: New and approved gloves and flash hoods were provided onboard and verified by DNV-GL
Fire Fighting › Remote Fuel Shutoff › General
Issued 30 November 2017Resolved
0730 - Appliances (general equipment) - Fire fighting systems shall be ready for use. The PSCO found the pressure reducing valve missing between the quick-closing air reservoir and the quick-closing valve actuators (in the fire control room) making all air actuated quick-closing valves inoperable. - SOLAS('14 cons)II-2/14.1 - 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2017
Resolved 4 December 2017
Resolution: MSU Savannah received Class report attesting to repairs. See narrative for details.
Engineering › Freshwater System (jacketwater cooling) › Level Control
Issued 30 November 2017Resolved
1410 - propulsion main engine - The condition of the ship shall be maintained to ensure it will remain fit to proceed to sea. The vessel's M/E #4 cylinder is leaking approximately one (01) cubic meter of water per day. - SOLAS(2014 cons) I/11 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2017
Resolved 4 December 2017
Resolution: MSU Savannah received Class report attesting to repairs. See narrative for details.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 30 November 2017Resolved
1721 - Retention of oil on board - Every ship of 400 GT & above shall be provided with tanks of adequate capacity to receive the oil residues which cannot be dealt with. The vessel's bilge tank is at capacity due to the jacket water leak identified in deficiency #2. - MARPOL(2011 cons.) I/12.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2017
Resolved 4 December 2017
Resolution: MSU Savannah received Class report attesting to repairs. See narrative for details.
Engineering › Pressure Vessel › Relief Valve
Issued 30 November 2017Resolved
1499 - Other (pro. and aux machinery) - Where pressure vessels are subject to dangerous overpressure, means shall be provided to protect against such excessive pressure. The 1st stage pressure vessel in the OWS system has no relief valve. The piping between the 1st and 2nd stage has a modified relief valve. - SOLAS ('14 cons) II-1/27.2
Action required: 705 - Other - as specified
Due 4 January 2018
Resolved 5 January 2019
Resolution: OWS overhauled and tested in the presence of DNV-GL
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 7 April 2017Resolved
1499-Other (Prop & Aux. Machinery)-The condition of the ship its equipment shall be maintained to conform with the provisions of present regulations to ensure that the ship remains fit to proceed to sea without danger to the ship or persons on board. PSCO observed excessive leaking of the jacket-water line between No. 2 & 3 cylinder heads of the main engine. SOLAS (14) I/11 17a
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2017
Resolved 13 April 2017
Resolution: Received class report attesting to rectified deficiency
1070-UMS Alarms-Internal combustion engines of 2,250 kW and above or having cylinders of more than 300mm bore shall be provided with crankcase oil mist detectors or engine bearing temperature monitors or equivalent devices. PSCO observed oil mist detector panel displaying an error code of E014: negative air pressure/air flow too low. SOLAS (14) II-1/47.2 17a
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2017
Resolved 13 April 2017
Resolution: Received class report attesting to rectified deficiency
Engineering › Fuel Oil Service System › Piping
Issued 7 April 2017Resolved
1499-Other(Prop. & Aux. Machinery)-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed fuel dripping from diesel fuel supply line to main engine. SOLAS (14) I/11 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2017
Resolved 13 April 2017
Resolution: Received class report attesting to rectified deficiency
Engineering › Fuel Oil Service System › Pump
Issued 7 April 2017Resolved
1499-Other(Prop. & Aux. Machinery)-The condition of the ship and its equipment shall be maintained to conform with the provisions of present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed excessive oil leaks on fuel oil booster unit and its alarm panel showed, "Pump 2 failure." SOLAS (14) I/11 16a
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 13 April 2017
Resolution: Received class report attesting to rectified deficiency
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 7 April 2017Resolved
1799-Other(MARPOL Annex I)-A ship in a port or an offshore terminal of another Party is subject to inspection by officers duly authorized by such Party concerning operational requirements under this Annex, where there are clear grounds for believing that the master or crew are not familiar with essential shipboard procedures. Crew were unfamiliar with OCM Alarm history function. MARPOL I/11 10c
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 7 April 2017
Resolution: Coast Guard Marine Inspector went over instruction manual for OWS with engineer and showed him proper operation.