Records from 2008 to 2019. Most recent: inspection, 24 January 2019.
Inspection history · 15
24 January 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6614711
21 January 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6640419
20 January 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6612627
4 January 2019
ISPS II Exam · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6605480
3 August 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6499797
30 November 2017
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6309845
25 October 2017
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6295069
24 October 2017
ISPS II Exam · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6291534
21 July 2017
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6223439
7 April 2017
ISPS II Exam · Ballast Water Examination · COE-Offshore · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6115579
28 January 2011
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3932038
6 January 2010
ISPS II Exam · Ballast Water Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3657505
13 May 2009
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3473643
8 October 2008
NPV Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3338558
7 February 2008
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3141551
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 4 January 2019
Resolved
1730 Any ship of 400 gross tonnage and above but less than 10000 gross tonnage shall be fitted with oil filtering equipment. Oil water separator is inoperable. MARPOL(2011 CONS.) I/14.1 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2019
Resolution: OWS overhauled and tested in the presence of DNV-GL
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 4 January 2019
Resolved
1730 Oil filtering equipment shall be of a design approved by the administration and shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15ppm. filtering media not changed in accordance with manufacture's instructions 1-2 years. MARPOL(2011 CONS.)I/14.6 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2019
Resolution: OWS overhauled and tested in the presence of DNV-GL
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 4 January 2019
Resolved
Personal Equipment shall consist of protective clothing to protect the skin from the heat radiating from the fire and from burns and scalding by steam. the outer surface shall be water resistant. PSCO observed fire fighter with gloves that were not fire resistant, also with exposed skin on face from improper hood protection. 74 solas(2014) II-2/10.1.1 FSS code ch.3 2.1.1 16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2019
Resolved 5 January 2019
Resolution: New and approved gloves and flash hoods were provided onboard and verified by DNV-GL
Fire Fighting › Remote Fuel Shutoff › General
Issued 30 November 2017
Resolved
0730 - Appliances (general equipment) - Fire fighting systems shall be ready for use. The PSCO found the pressure reducing valve missing between the quick-closing air reservoir and the quick-closing valve actuators (in the fire control room) making all air actuated quick-closing valves inoperable. - SOLAS('14 cons)II-2/14.1 - 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2017
Resolved 4 December 2017
Resolution: MSU Savannah received Class report attesting to repairs. See narrative for details.
Engineering › Freshwater System (jacketwater cooling) › Level Control
Issued 30 November 2017
Resolved
1410 - propulsion main engine - The condition of the ship shall be maintained to ensure it will remain fit to proceed to sea. The vessel's M/E #4 cylinder is leaking approximately one (01) cubic meter of water per day. - SOLAS(2014 cons) I/11 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2017
Resolved 4 December 2017
Resolution: MSU Savannah received Class report attesting to repairs. See narrative for details.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 30 November 2017
Resolved
1721 - Retention of oil on board - Every ship of 400 GT & above shall be provided with tanks of adequate capacity to receive the oil residues which cannot be dealt with. The vessel's bilge tank is at capacity due to the jacket water leak identified in deficiency #2. - MARPOL(2011 cons.) I/12.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2017
Resolved 4 December 2017
Resolution: MSU Savannah received Class report attesting to repairs. See narrative for details.
Engineering › Pressure Vessel › Relief Valve
Issued 30 November 2017
Resolved
1499 - Other (pro. and aux machinery) - Where pressure vessels are subject to dangerous overpressure, means shall be provided to protect against such excessive pressure. The 1st stage pressure vessel in the OWS system has no relief valve. The piping between the 1st and 2nd stage has a modified relief valve. - SOLAS ('14 cons) II-1/27.2
Action required: 705 - Other - as specified
Due 4 January 2018
Resolved 5 January 2019
Resolution: OWS overhauled and tested in the presence of DNV-GL
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 7 April 2017
Resolved
1499-Other (Prop & Aux. Machinery)-The condition of the ship its equipment shall be maintained to conform with the provisions of present regulations to ensure that the ship remains fit to proceed to sea without danger to the ship or persons on board. PSCO observed excessive leaking of the jacket-water line between No. 2 & 3 cylinder heads of the main engine. SOLAS (14) I/11 17a
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2017
Resolved 13 April 2017
Resolution: Received class report attesting to rectified deficiency
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 7 April 2017
Resolved
1070-UMS Alarms-Internal combustion engines of 2,250 kW and above or having cylinders of more than 300mm bore shall be provided with crankcase oil mist detectors or engine bearing temperature monitors or equivalent devices. PSCO observed oil mist detector panel displaying an error code of E014: negative air pressure/air flow too low. SOLAS (14) II-1/47.2 17a
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2017
Resolved 13 April 2017
Resolution: Received class report attesting to rectified deficiency
Engineering › Fuel Oil Service System › Piping
Issued 7 April 2017
Resolved
1499-Other(Prop. & Aux. Machinery)-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed fuel dripping from diesel fuel supply line to main engine. SOLAS (14) I/11 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2017
Resolved 13 April 2017
Resolution: Received class report attesting to rectified deficiency
Engineering › Fuel Oil Service System › Pump
Issued 7 April 2017
Resolved
1499-Other(Prop. & Aux. Machinery)-The condition of the ship and its equipment shall be maintained to conform with the provisions of present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed excessive oil leaks on fuel oil booster unit and its alarm panel showed, "Pump 2 failure." SOLAS (14) I/11 16a
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 13 April 2017
Resolution: Received class report attesting to rectified deficiency
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 7 April 2017
Resolved
1799-Other(MARPOL Annex I)-A ship in a port or an offshore terminal of another Party is subject to inspection by officers duly authorized by such Party concerning operational requirements under this Annex, where there are clear grounds for believing that the master or crew are not familiar with essential shipboard procedures. Crew were unfamiliar with OCM Alarm history function. MARPOL I/11 10c
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 7 April 2017
Resolution: Coast Guard Marine Inspector went over instruction manual for OWS with engineer and showed him proper operation.