Records from 2008 to 2026. Most recent: inspection, 22 June 2026.
Documentation record
Registered dimensions (L × B × D)180.0 ft × 40.0 ft × 15.0 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)180.0 ft × 40.0 ft × 15.0 ft
ITC tonnagegross 870 / net 261
BuilderBOLLINGER SHIPYARDS LOCKPORT LLC · LOCKPORT, LA, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 31 March 2026 · expires 30 April 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it870 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
261 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
22 June 2026
Vessel Attendance · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8410331
14 May 2026
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8371246
24 September 2025
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8240281
18 December 2024
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8042030
5 September 2023
MTSA Verification · Drydock Exam · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7784864
28 November 2022
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7600900
21 October 2021
Periodic Inspection · Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7337361
25 November 2020
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7101402
20 May 2020
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6963403
5 December 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6867681
27 August 2018
Administrative Inspection · Cargo Tank Internal · COI Inspection · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6524325
1 February 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6347671
9 November 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6039171
28 October 2016
Hull Examination · Administrative Inspection · Internal Structural Exam · Cargo Tank Internal · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6031330
15 December 2015
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5782476
14 October 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5002882
31 January 2011
Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3936818
29 December 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3945585
12 February 2010
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3679342
1 February 2010
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3673702
10 November 2008
Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3360691
7 March 2008
Initial Certification · COI Inspection · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3160273
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 December 2024
Resolved
Electrical equipment on a vessel must be designed, installed and maintained to provide services necessary for safety under all normal and emergency conditions. The installed fixed fire detection and other safety related automation alarms' back up (emergency) power source is inoperable. The system is equipped with a battery as a secondary source of power when the ship's SSGs are down, however, the connection to the back up system is not being made. Make repairs and prove proper operation of the emergency source of power.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 December 2024
Resolved 19 December 2024
Resolution: Deficiency rectified by installing proper switch.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 December 2024
Resolved
Each OSV must carry a category 1 606 MHz satellite EPIRB meeting the requirements of 47 CFR part 80. The EPIRB installed onboard has a battery that expired in November 2024 according to manufacturer requirements. Replace battery or EPIRB. If a new EPIRB is provided, ensure it is registered correctly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2025
Resolved 19 December 2024
Resolution: New EPIRB and registration provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 December 2024
Resolved
A rudder-angle indicator (RAI) independent of the control of the main steering gear must be installed at the steering-control station in the pilot house. It was observed that the RAI for the port rudder was not reading past 10 degrees to port and was erratic in its movement. Make repairs and prove proper operation of RAIs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2025
Resolved 19 December 2024
Resolution: Adjustments made to RAI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 September 2023
No resolution recorded
Keel cooler installations must comply with 46 CFR 56.50-96.
46 CFR 56.50-96(a)(2)(iv)- the forward end of the structure must be faired to the hull such that the horizontal length of the fairing is no less than 4 times the height of the structure.
There is no fairing on the forward end of the keel coolers.
MSU Houma OCMI has extended due date for deficiency to the next dry docking period.
Action required: 705 - Other - as specified
Due 30 September 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 October 2021
Resolved
The following items shall be completed prior to issuing the vessel credit for a completed DD/ISE/CTIE.
1.) Starboard bow thruster had hydraulic leak coming from the hub; rectify prior to bringing the vessel back into the water.
2.) Rudder post thread was worn; renew as original.
3.) 03 cracked welds were discovered in the port side stern wrap; gouge and reweld.
4.) 03 supports for the steering gear hydraulic lines were heavily corroded; replace in kind.
5.) Forepeak valve connected to the reach-rod was heavily corroded; renew as original.
6.) #6 P/S liquid mud tanks had unserviceable reach-rods connected to the keel coolers; renew as original.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 November 2020
Resolved
EMERGENCY ESCAPE HATCH IN THE ENGINE ROOM IS NOT WATERTIGHT, LIGHT COULD BE SEEN FROM THE INSIDE WHEN IT'S CLOSED.
EACH HATCH EXPOSED TO THE WEATHER MUST BE WATERTIGHT.
REPLACE GASKET AND ADJUST HATCH TO MAKE WATERTIGHT.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 November 2020
Resolution: escape hatch was adjusted and wtinessed by ABS
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 25 November 2020
Resolved
EMERGENCY LIGHTING IS NOT BRIGHT ENOUGH TO BE EFFIECIENT.
A VESSEL OF LESS THAN 100 GROSS TONS MUST HAVE ADEQUATE EMERGENCY LIGHTING FITTED ALONG THE LINE OF ESCAPE TO THE MAIN DECK FROM ACCOMODATIONS AND WORKING SPACES BELOW THE MAIN DECK.
FIX EMERGENCY LIGHTING SO THAT THE LINE OF ESCAPE CAN BE ADEQUATELY SEEN.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 December 2020
Resolved 30 November 2020
Resolution: new batteries were purchased and installed for emergency lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 November 2020
Resolved
TWO NONMETALLIC FLEXIBLE FUEL HOSES ON THE PORT MAIN DIESEL ENGINE AND TWO ON THE AFT GENERATOR WERE DRY ROTTEN AND LEAKING.
FLEXIBLE HOSE INSTALLATIONS MUST BE REPLACED IAW SAEJ 1942 STANDARDS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 December 2020
Resolved 30 November 2020
Resolution: new fuel hoses were purchased and installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 December 2019
Resolved
Replace gasket and adjust engine room emergency escape hatch to make wateright.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2019
Resolved 5 December 2019
Resolution: Vessel sent pictures to MI showing installment of new gasket material.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 5 December 2019
Resolved
The communication systems are inoperable during loss of main ship's power. Make operable 1 VHF Radio and PA system during power loss. 46 CFR 129.310
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2019
Resolved 5 December 2019
Resolution: Vessel installed new battery to enable VHF and PA system operability during loss of ship's power.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 December 2019
Resolved
The lighting globes for fixtures in walk-in reefer and freezers are melted. Provide suitable fixtures for the electrical current used.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2019
Resolved 5 December 2019
Resolution: Vessel installed new globe and fixture rated for a lower wattage.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 27 August 2018
Resolved
Vessel requires at least 2 sources electricity. Aft generator breaker would not close leaving only 1 source of electricity for fire protection equipment. Identifiy and correct issue to the satifaction of attending USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 5 September 2018
Resolved 5 September 2018
Resolution: Problem corected and reverse power on both generator tested.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 9 November 2016
Resolved
Obtain and provide on board a non-tank vessel response plan approval letter and shipboard oil pollution emergency plan (SOPEP)/shipboard marine emergency plan (SMPEP) approval letter. Provide nontank vessel response plan and SOPEP/SMPEP onboard vessel. IAW 33CFR155 subpart J by 09 DEC 2016
Due 9 December 2016
Resolved 1 December 2016
Resolution: Vessel provided required documents. See activity 6039171.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 15 December 2015
Resolved
08 fuel filter strainers were made of plastic and did not meet IMO resolution A.753(18) as required by 46CFR56.60-25(a)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 January 2016
Resolved 15 January 2016
Resolution: Email sent with newly installed system.
Fire Fighting › Portable Foam Applicators › General
Issued 15 December 2015
Resolved
Eductor for foam application on back deck did not work.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 9 November 2016
Resolution: Witnessed satisfactory operation of in-line eductor.
Communications › Internal Communications System › Sound-powered Telephone
Issued 31 January 2011
Resolved
Not audible from brigde to engine room.
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 23 September 2011
Resolution: VSL Rep confirmed complete rerouting of comms to E/R.
Communications › Alarms/Indicators › General Alarm
Issued 1 February 2010
Resolved
Demonstrate General Alarm on Emergency power.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2010
Communications › Public Address System › Amplifier
Issued 1 February 2010
Resolved
Demonstrate PA on Emergency Power
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2010