Records from 2013 to 2026. Most recent: inspection, 20 March 2026.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for rating able seafarer deck/engine and electro-technical
Issued 20 March 2026
Resolved
Except as otherwise provided in this section, on a documented vessel, each unlicensed seafarer (seaman) must be: a citizen of the US, an alien lawfully admitted to the US for permanent residence; or a foreign national who is enrolled in the USMMA.
Marine Inspector was notified of 01 non-US resident employed on vessel.
17-Vessel is may complete operations and return to Port Fourchon to offload unauthorized non-US citizen crew member. Vessel must comply with 46 USC 8103 prior to movement.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2026
Resolved 6 April 2026
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 October 2025
Resolved
On vessels required by § 112.05-5(a) to have a temporary emergency power source, the following emergency lighting and power loads must be arranged so that they can be energized from the temporary emergency power source:Lighting, ... for passageways, stairways, and escape trunks in ... public spaces, [and] machinery spaces, ... sufficient to allow passengers and crew to find their way to open decks and to survival craft, muster stations, and embarkation stations with all watertight doors and fire doors closed. Emergency lighting in the rudder room, bow thruster room, and galley provided insufficient illumination.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2025
Resolution: Owner replaced in kind the worn out battle laterns with new lanterns.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 October 2025
Resolved
There shall be at least two means of escape from all general areas accessible to the passengers, if carried, or where the crew may be quartered or normally employed. The emergency escape door from the engine room needs to be adjusted to open and close properly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2025
Resolution: The closing mechanism was cleaned, lubricated, and adjusted. MI verified proper operation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 October 2025
Resolved
Oil piping drains, strainers, and other equipment subject to normal oil leakage must be fitted with drip pans or other means to prevent oil draining into the bilge. The fuel filters on the main engines, generator prime movers, and bow thruster engine were missing drip trays.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 October 2025
Resolution: Drip trays were fabricated and installed under prime mover fuel filters.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 October 2025
Resolved
Amendments to a Vessel Security Plan that are approved by the Marine Safety Center (MSC) may be initiated by: The Coast Guard upon a determination that an amendment is needed to maintain the vessel's security. The company owner or operator will have at least 60 days to submit its proposed amendments. The VSP on-board the vessel was not amended for the last two changes in CSO. Ensure the new CSO has appropriate and documented training/experience for the position. Submit an amendment to MSC and ensure appropriate training of the CSO in 60 days.
Action required: 705 - Other - as specified
Due 16 December 2025
Resolved 15 January 2026
Resolution: The vessel rep for the inspection left the company, the owner made updates to the plan and submitted for review.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 15 October 2025
Resolved
When alteration or repair of boilers, pressure vessels, machinery, safety valves or piping systems becomes necessary, the work must be done under the cognizance of the Officer in Charge Marine Inspection. The Calcium Chloride piping was temporarily soft patch repaired, complete final weld repair to the satisfaction of the [name withheld] repair prior to carriage of Calcium Chloride or other cargo using its transfer system.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 October 2025
Resolution: Vessel rep provided video of the weld repairs pressed up internally to 95 psi, and walking the repaired sections. No leaks found.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 August 2025
Resolved
Sector NOLA was notified of an allision with platform VK 817A which damaged pilot house, bow and stbd side shell.
Vessel to conduct repairs of affected areas to the satisfaction of the attending MI.
46CFR91.30-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2025
Resolution: Vessel conducted extensive hull repair and electronics replacement under CG and ABS supervision. All repairs were satisfactory to both parties. Electronics tested during ANN insp.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 26 February 2025
Resolved
Each rescue boat must be stripped, cleaned, and thoroughly inspected and repaired as needed at least once a year. This procedure includes emptying and cleaning each fuel tank and refilling it with fresh fuel. Vessel could not provide documentation of annual rescue boat servicing.
46 CFR 131.575(a)
(L service)
46CFR90.27-1
46CFR199.190(f)(2)
(I service)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2025
Resolved 27 February 2025
Resolution: A third party company attended and completed annual servicing of the rescue boat.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 26 February 2025
Resolved
Each OSV must carry a EPIRB meeting the requirements of 47 CFR part 80. Vessel's EPIRB battery was expired.
46CFR133.60(a)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2025
Resolved 26 February 2025
Resolution: Post inspection the vessel POC provided Technician invoice and proof of new EPIRB onboard.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 February 2025
Resolved
Each refrigerated space that is accessible to the vessel's personnel and that can be locked from the outside so that it cannot be opened from the inside, must have an audible alarm system that can be operated from within the refrigerated space. Vessel has lockable refrigerated spaces without audible alarms.
46 CFR 113.45(a)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2025
Resolved 27 February 2025
Resolution: The refrigerated spaces that were lockable but did not have locked in alarms were made to where they were unable to be locked.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 26 February 2025
Resolved
Owners and operators of applicable vessels must establish a master key control system and related provisions for use of master keys, and record keeping. Vessel does not currently have a master key control system.
46 USC 3106(a)(1)
CVC Policy Letter 23
46 USC 3106
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 27 February 2025
Resolution: Vessel provided letterhead that to comply with the Master [name withheld] portion of the Safer Seas Act, the vessel will only utilize keyless locks at applicable locations. The existing locks were changed to keyless. See documents tab.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 February 2025
Resolved
Each davit, winch, and fall must be thoroughly inspected at least once a year and repaired as needed. Vessel could not provide documentation of annual davit servicing.
46 CFR 131.575(b)
(L service)
46CFR90.27-1
46CFR199.190(f)(2)
(I service)
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2025
Resolved 27 February 2025
Resolution: A third party company attended and completed annual servicing of the davit.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 26 February 2025
Resolved
Each vessel must comply with 47 CFR part 80 as applicable. Vessel did not have valid FCC Bridge to Bridge or Radio-safety telephone certs. Third party attended and issued both during the inspection.
46 CFR 130.210
Action required: 10 - Deficiency Rectified
Due 26 February 2025
Resolved 26 February 2025
Resolution: Third party attended and issued both during the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 December 2023
Resolved
Proper servicing of hydrostatic release unit shall be conducted.
Hydrostatic release on epirb was expired. Replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2023
Resolution: Replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 December 2023
Resolved
Life buoys and associated equipment shall be of proper conditions.
Float light batteries expired. Replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2023
Resolution: Replaced batteries.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 December 2023
Resolved
Watertight doors must be watertight.
FWD engine room door not adjusted properly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2023
Resolution: Adjusted door. Tested in presence of MI, sat.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 December 2023
Resolved
Each fire station must have a fire hose.
Fire hose was leaking. Replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2023
Resolution: Replaced fire hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2023
Resolved
Rotating machinery must have a guard.
STBD generator alternator cover had gaps in cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2024
Resolved 2 January 2024
Resolution: Guard fixed to cover gaps.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 December 2023
Resolved
Visible and audible alarms must be installed in the pilot house for high bilge level.
Rudder room bilge alarm was showing "spare" when activated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2024
Resolved 4 January 2024
Resolution: Tech reprogrammed alarm panel, rudder room now shows on the screen.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 9 August 2023
Resolved
Vessel discharged diesel during fueling operation due to faulty valve. Valve must be replaced prior to transfering fuel or transfer procedures must be updated.
Action required: 705 - Other - as specified
Resolved 15 August 2023
Resolution: Valve replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 2 March 2023
Resolved
Lifesaving appliances and arrangements are subject to tests and inspections described in paragraph (b) of this section during OSV boarding to ensure that the appliances and arrangements comply with applicable requirements, are in satisfactory condition, and remain fit for service. During the emergency test of the rescue boat davit the system was found to be overfilled with hydraulic fluid and releasing hydraulic fluid out on deck through the vent.
46 CFR 133.45 (C)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2023
Resolution: Hydraulic fluid levels were adjusted and witness satisfactory test of the davit on stored energy.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 2 March 2023
Resolved
Each OSV must carry at least one rescue boat. Each rescue boat must be approved under approval series 160.156 and equipped as specified in table 133.175 of this part. The rescue boat is not equipped with the self-righting lines.
46 CFR 133.135 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2023
Resolution: Righting lines were placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 2 March 2023
Resolved
Each OSV must have posters or signs displayed in the vicinity of each survival craft and the survival craft's launching controls. Emergency instructions for the rescue boat davit were not posted.
46 CFR 133.90
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2023
Resolution: Instructions were posted onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 2 March 2023
Resolved
At least two lifebuoys, each with attached self-activating smoke signals, must be stowed where they can be quickly released from the navigating bridge and should, when released, fall directly into the water without striking any part of the vessel. The life buoys installed onboard the bridge wings were not rated for “quick release”.
46 CFR 199.70(v)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2023
Resolution: The proper life rings were placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 March 2023
Resolved
Each lifebuoy must be capable of being rapidly cast loose. Life buoys on the 01 deck and main deck were not ready for service.
46 CFR 199.70(a)(1)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2023
Resolution: Life buoys were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 March 2023
Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.112 or 161.012 securely attached to the front shoulder area of the lifejacket. 02 lifejackets in the staterooms had inoperable lights.
46 CFR 133.70(b)(4)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2023
Resolution: Batteries were replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 March 2023
Resolved
The marine employer must have a sufficient number of urine-specimen collection and shipping kits meeting the requirements of 49 CFR part 40 that are readily accessible for use following SMIs. The specimen collection and shipping kits need not be carried on board each vessel if obtaining the kits and collecting the specimen can be completed within 32 hours from the time of the occurrence of the SMI. The vessel is certified for oceans routes and is not supplied with specimen collection kits or collector training.
46 CFR 4.06-15
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 March 2023
Resolution: Chemical testing kits were acquired from the company's drug testing consortium.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 2 March 2023
Resolved
The installation of all systems of an electrical engineering or interior communication nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter J (Electrical Engineering) of this chapter. The means of communication and calling must be a reliable means of voice communication and must be independent of the vessel's electrical system. MI observed that the ship’s internal means of communication via installed telephones was not connected to emergency power.
46 CFR 96.05-1(a)
46 CFR 113.30-3(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2023
Resolution: A faulty connection to the charger was replaced as well as the battery. System was operationally tested, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2023
Resolved
The installation of all systems of an electrical engineering or interior communication nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter J (Electrical Engineering) of this chapter. Each generator prime mover must have an overspeed device that is independent of the normal operating governor and adjusted so that the speed cannot exceed the maximum rated speed by more than 15 percent. MI observed that the vessel did not have records onboard of the generator prime mover overspeed device having been tested. Provide technician report attesting to proper functionality.
46 CFR 96.05-1(a)
46 CFR 111.12-1(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 March 2023
Resolution: Received documentation from manufacture that the electronic controls for the prime mover prohibit the engine from being testing overspeed alarm due to risk of severe damage to the engine or generator.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 12 March 2021
Resolved
Each EPIRB unit must be programmed with a unique identification code and registered with NOAA; vsl EPIRB registration had wrong call sigh unique to the vessel DRY TOURTUGAS; Prove correct call sign with NOAA epirb registration.
46CFR133.60 47CFR80.1061(e)
Action required: 10 - Deficiency Rectified
Due 12 March 2021
Resolved 12 March 2021
Resolution: Vsl called NOAA and alligned call sign with FCC docs
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 March 2021
Resolved
Each temporary source of emergency power must contain battery storage sufficient capacity to supply emergency loads; back up battery for general alarm and radio was not operational; replace battery that meets requirements in 46CFR112.37-1
Action required: 10 - Deficiency Rectified
Due 12 March 2021
Resolved 12 March 2021
Resolution: Vsl replaced batteries
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 12 March 2021
Resolved
Search light battery on the rescue boat shall be maintained in accordance with table 133.175, operational. Search light battery was not functional resulting in an inoperable search light. Replace battery to provide required power.
Action required: 10 - Deficiency Rectified
Due 12 March 2021
Resolved 9 April 2021
Resolution: Vsl replaced battery
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 March 2021
Resolved
Fluid conditioner fittings (fuel filters) shall be made in accordance with the adopted standards of ASTM F 1201 in 46 CFR 56.60-1(b). Fuel filters had a glass bowl which does not meet the ASTM fire rating. Deficiency to be cleared by next drydock.
56.15-5((b), 46CFR56.60-1(b), ASTM F 1201
Action required: 705 - Other - as specified
Due 19 December 2021
Resolved 30 July 2021
Resolution: Verified replacement of glass bowls by metal ones prior to next drydock
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 March 2021
Resolved
Each vsl must provide an Employee Assistance Program/ Drug and Alcohol Policy (EAP/DAPI) and display and distribution of information materials; VSL did not display contact info for employees. Display info in public area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2021
Resolved 15 March 2021
Resolution: Vsl got EAP book form office and posted info in common space
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 March 2021
Resolved
Each lifebuoys must be marked in block capital letters with the name of the OSV and name of the port of registry; the lifebuoy located on the forecastle was faded and not legible; provide markings meeting stated requirements
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2021
Resolved 9 April 2021
Resolution: Vsl provided markings to be clear and legible
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 26 February 2021
Resolved
Vessel must carry the personnel required by the Certificate of Inspection (COI). During the inspection, vessel did not provide minimum required manning per vessel's COI; for inspection to be completed, a complete crew per the COI must be available and onboard.
Action required: 60 - Rectify deficiencies prior to movement
Due 26 February 2021
Resolved 12 March 2021
Resolution: Inspection team attended to conduct an annual inspection, verifying proper manning
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 March 2020
Resolved
The three life-buoys with self-igniting lights had expired batteries. The Starboard Bridge Buoy needs to be re-stenciled with the vessel name and port. The retro-reflective tape needed to be replaced on both the Port/Starboard Bridge buoys.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2020
Resolved 25 March 2020
Resolution: Replaced items.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 March 2020
Resolved
The watertight door leading to the forward storage compartment had a tightening tensioner (dog) that was loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2020
Resolved 25 March 2020
Resolution: Adjust loose dog on W/T door.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 March 2020
Resolved
The USCG and/or ABS was not made aware of major alterations affecting the safety of the vessel. Specifically, the aft bulwarks were cropped out and removed from the vessel to accommodate a job. An inspection of the hull repairs are to be observed by either a USCG Marine Inspector and/or ABS Surveyor.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2020
Resolved 25 March 2020
Resolution: Repairs made to bulwarks.
Lifesaving › Line-Throwing Appliances › Lines
Issued 7 February 2018
Resolved
cannisters for line throwing appliances were found expired. replace cannisters.
Due 14 February 2018
Resolved 14 February 2018
Resolution: Vessel provided new line throwing appliances on board.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 7 February 2018
Resolved
Embarkation station ligting found not working.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 February 2018
Resolution: Vessel rep provided proof of repairs to embarkation lighting.
Engineering › Bilge Water Management System › Strainer
Issued 7 February 2018
Resolved
Bilge suctions lacked strainers.
Due 14 February 2018
Resolved 14 February 2018
Resolution: Vessel crew installed expanded metal strainers to bilge suctions.
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 February 2017
Resolved
Alarm Panel on Bridge was inop.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 February 2017
Resolved 24 February 2017
Resolution: Panel Repaired.
Engineering › Fuel Oil Service System › Filter
Issued 24 February 2017
Resolved
Fuel Filters were plastic on both generators
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 1 March 2017
Resolution: New filters installed
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 February 2017
Resolved
Guards around rotating machinery on generators were missing.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 February 2017
Resolved 24 February 2017
Resolution: Reinstalled
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 24 February 2017
Resolved
Post emergency steering procedures at emergency steering location.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 February 2017
Resolved 24 February 2017
Resolution: New Instructions posted
Engineering › Pressure Vessel › Pressure Gauge
Issued 24 February 2017
Resolved
Inproper Pressure gauge was installed.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 24 February 2017
Resolution: Proper gauge was installed
Lifesaving › Lifebuoys › Stowage
Issued 24 February 2017
Resolved
Bridge lifebouys release was inoperable.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 24 February 2017
Resolution: Maintance was completed and lifebouy releases worked.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 February 2017
Resolved
Vessel operated 10 months past drydock, Internal Structure and Cargo tank internal inspections drop dead date of 25APR16.
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Resolution: Conducted drydock, ISE and CTIE inspections
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 February 2017
Resolved
Vessel operated 10 months past due date for ISE
Due 15 February 2017
Resolved 15 February 2017
Resolution: Completed ISE